11.
Connect CD electrode to power supply connector.
12.
Slide cover into position while lifting the base of the cover up.
13.
Lower cover over CD electrode and snap cover tabs into place.
14.
Replace cover Screw
15.
Reinstall the EC-AGX into the original mounting location; reconnect ozone
supply tubing to hose barb and reconnect the power cord.
4D. Trouble Shooting
Knowledge of electrical applications is required for trouble shooting. Contact a
certified electrician if you are unsure of your ability to service the equipment. Im-
proper servicing will void the Warranty.
Symptom:
No Flow.
1.
Injector not supplying adequate suction.
a.
Check pump and ensure water is flowing through injector.
b.
Check that pump skimmer and filter are clean.
c.
Check that injector is plumbed in the right direction.
d.
Ensure that there is no debris clogged inside the injector.
2.
Tubing is impaired.
a.
Check for kinks or clogs.
b.
Check for cracks or cuts.
c.
Check connections.
d.
Check that the check valve is installed with the arrow pointing towards
the injector.
e.
Be sure that the check valve has not become fouled with debris.
Disconnect the ozone tubing from the injector. With the pump running,
test the end of the hose barb with your thumb, and feel for suction. Wash
your hands immediately afterwards to remove any residual nitric acid. If
there is sufficient suction without the check valve, replace the check valve
and tubing.
Symptom:
Ozone tubing becomes yellow/brown and brittle.
1.
The high concentration of ozone created by the corona discharge ozone
generators, as well as environmental conditions like UV sunlight will tend
to deteriorate the supplied ozone tubing. This is normal and acceptable,
as long as the tubing doesn’t become cracked and leak. Because of this,
DEL recommends replacing the ozone supply tubing and your check valve
every year.
12
EC-AGX Installation & Operation Manual
SECTION 2 Installation
2A Location
The ozone generator units are designed for wall mounting. See Figure 1. Mount
generator in a clean, protected area, either indoors or outdoors (preferably out of
direct sunlight). Locate generator out of reach of sprinklers or drainage spouts.
Allow sufficient access for maintenance and all tubing and electrical wires. Ozone
generator should be installed at least (not less than) one foot above the maximum
water level. See Section 2D-2, Ozone Gas Line, for plumbing instructions based
on mounting location.
2B Wall Mounting
1.
Refer to Figure 1 to mark the locations for the two mounting screws.
2.
Install screws (or other hardware appropriate for mounting surface) through
the two mounting holes built in to the base of the EC-AG ozone system.
Figure 1
Wall Mount
2C Electrical
2C-1. Main Power:
Connect the ozone generator to the pool timing clock so that
the ozone generator operates simultaneously with the pool pump. The circuit must
be protected by a ground-fault circuit interrupter (GFCI) installed in accordance to
electrical code. Refer to the IMPORTANT SAFETY INSTRUCTIONS at the beginning
of this manual for important wiring information.
If the EC-AG power cord comes with a built-in receptacle and the pump is equipped
with a standard plug (NEMA 5-15P), the pump may be plugged in on top of the EC-
AG cord (pump current must not exceed 15A). Plug must be protected from mois-
ture.
5