background image

11. 

Connect CD electrode to power supply connector.

12. 

Slide cover into position while lifting the base of the cover up.

13. 

Lower cover over CD electrode and snap cover tabs into place.

14. 

Replace cover Screw

15. 

Reinstall the EC-AGX into the original mounting location; reconnect ozone 

 

supply tubing to hose barb and reconnect the power cord.

4D. Trouble Shooting 

Knowledge of electrical applications is required for trouble shooting. Contact a 
certified electrician if you are unsure of your ability to service the equipment. Im-
proper servicing will void the Warranty.

Symptom:

 No Flow.

1. 

Injector not supplying adequate suction. 

    a. 

Check pump and ensure water is flowing through injector. 

    b. 

Check that pump skimmer and filter are clean. 

    c. 

Check that injector is plumbed in the right direction. 

    d. 

Ensure that there is no debris clogged inside the injector. 

2. 

Tubing is impaired. 

    a. 

Check for kinks or clogs. 

    b. 

Check for cracks or cuts. 

    c. 

Check connections. 

    d. 

Check that the check valve is installed with the arrow pointing towards 

 

the injector. 

    e. 

Be  sure  that  the  check  valve  has  not  become  fouled  with  debris. 

 

Disconnect  the  ozone  tubing  from  the  injector.  With  the  pump  running, 

 

test the end of the hose barb with your thumb, and feel for suction. Wash 

 

your hands immediately afterwards to remove any residual nitric acid. If 

 

there is sufficient suction without the check valve, replace the check valve 

 

and tubing.

 

 

Symptom:

 Ozone tubing becomes yellow/brown and brittle.

1. 

The high concentration of ozone created by the corona discharge ozone 

 

generators, as well as environmental conditions like UV sunlight will tend 

 

to deteriorate the supplied ozone tubing. This is normal and acceptable, 

 

as long as the tubing doesn’t become cracked and leak. Because of this, 

 

DEL recommends replacing the ozone supply tubing and your check valve 

 

every year. 

12

EC-AGX Installation & Operation Manual

SECTION 2 Installation

2A Location 

The  ozone  generator  units  are  designed  for  wall  mounting.  See  Figure  1.  Mount 
generator in a clean, protected area, either indoors or outdoors (preferably out of 
direct  sunlight).  Locate  generator  out  of  reach  of  sprinklers  or  drainage  spouts. 
Allow sufficient access for maintenance and all tubing and electrical wires. Ozone 
generator should be installed at least (not less than) one foot above the maximum 
water level.  See Section 2D-2, Ozone Gas Line, for plumbing instructions based 
on mounting location.

2B Wall Mounting 

1. 

Refer to Figure 1 to mark the locations for the two mounting screws. 

2. 

Install screws (or other hardware appropriate for mounting surface) through 

the two mounting holes built in to the base of the EC-AG ozone system. 

Figure 1

 Wall Mount

2C Electrical 

2C-1. Main Power:

 Connect the ozone generator to the pool timing clock so that 

the ozone generator operates simultaneously with the pool pump. The circuit must 
be protected by a ground-fault circuit interrupter (GFCI) installed in accordance to 
electrical code. Refer to the IMPORTANT SAFETY INSTRUCTIONS at the beginning 
of this manual for important wiring information.
If the EC-AG power cord comes with a built-in receptacle and the pump is equipped 
with a standard plug (NEMA 5-15P), the pump may be plugged in on top of the EC-
AG cord (pump current must not exceed 15A). Plug must be protected from mois-
ture.

5

Содержание EC-AG1

Страница 1: ......

Страница 2: ...in accordance with the installation instructions 8 Follow all applicable electrical codes 9 Electric shock hazard Be sure to turn power OFF and disconnect from power source before any service work is...

Страница 3: ...be refused Upon receipt of preauthorized returned goods DEL Ozone will repair or replace at DEL Ozone s option the defective product s and return them freight prepaid for products under warranty Buyer...

Страница 4: ...transferable to any subsequent owners or purchasers of such products DEL Ozone warrants that it or its authorized dealers will repair or replace at its option any part of such products proven to be de...

Страница 5: ...as well as environmental conditions like UV sunlight will tend to deteriorate the supplied ozone tubing This is normal and acceptable as long as the tubing doesn t become cracked and leak Because of t...

Страница 6: ...r See Figure 2a or Figure 2b CD Ozone System Figure 2 Installation Schematic for Injector Assembly 6 Check Valve EC AG Ozone Generator Ozone Out Fitting Ozone Supply Tubing Pump Filter Heater EC AGX I...

Страница 7: ...AGX Installation Operation Manual 7 Venturi Injector 1 1 2 Nipple Ozone Port Unplugged 1 1 2 Elbow Hose Barb Fitting Pool Return Hose Stainless Steel Hose Clamp 2D 2 Ozone Gas Line Connect the end of...

Страница 8: ...Manual 9 4B System Maintenance 4B 1 Ordering Information To locate a dealer nearest you call 1 800 676 1335 ext 249 or visit our web site www delozone com Be prepared with the following information N...

Отзывы: