![Del ozone Big Dipper EC-AG1U Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/del-ozone/big-dipper-ec-ag1u/big-dipper-ec-ag1u_installation-and-operation-manual_2465627012.webp)
8
EC–AG
Installation & Operations Manual
4C-3. Ozone Module Replacement
a. Open the Ozone Generator as described in section 4C-2.
b. Remove the Mounting Hardware.
c. Disconnect power supply connector (red & black wires).
d. Lift Ozone Cells, Grommet, Hose Barb Fitting, and Ozone Tubing
up and out from the Base Plate.
e. Remove and discard Ozone Cell, Power Supply, Hose Barb
Fitting, and Ozone Tubing.
f. Place new Grommet into enclosure wall.
g. Insert new Hose Barb Fitting making sure to align the Hose Barb
Fitting correctly and insert it completely into Grommet.
h. Install Power Supply with Mounting Hardware Route Power
Supply wires to the left side of the Base Plate.
i. Connect Power Supply connectors to wire harness.
j. Slide cover into position while lifting the base of the cover up.
k. Lower cover over Ozone Cell and snap Cover Tabs into place.
l. Replace Cover Screw.
m. Reinstall the EC–AG in to the pool, reconnect Ozone Supply
Tubing to Hose Barb Fitting and reconnect the power cord.
4D. Troubleshooting
Knowledge of electrical applications is required for trouble shooting.
Contact a certified electrician if you are unsure of your ability to
service the equipment. Improper servicing will void the Warranty.
Figure 6: Internal Component Locations
POWER SUPPLY
MOUNTING HARDWARE
OZONE CELL
HOUSE BARB FITTING
BASE PLATE
OZONE TUBING
GROMMET
Содержание Big Dipper EC-AG1U
Страница 1: ...EC AG1U EC AG2U Installation Operations Manual 4 2353 01 Rev A...