2
3
Aquaclipse
Installation & Operations Manual
Aquaclipse
Installation & Operations Manual
What's in the box?
1. Aquaclipse Ozone Generator
2. Parts Bag (P/N 9-1190-01)
a. Squeeze Clamp (P/N 7-0021)
b. Squeeze Clamp x2 (P/N 7-1453-
01)
c. Check Valve & Tubing Assembly
(P/N 9-0796-01)
d. 3/8" ID Tubing (P/N 7-1430-01)
e. Manual (P/N 4-2191-01)
f. Dispersion Stone (P/N 7-1513-01)
1B. Specifications
Compressor Flow
15 SCFH @ 10 psi
Power Requirements
ZO-400:
120VAC, 60Hz, 1Ø, 2.3A
ZO-400-25 :
230VAC, 50Hz, 1Ø, 1.3A
Shipping Weight
ZO-400:
25 lbs. (11.6 kg)
ZO-400-25 :
26 lbs. (11.8 kg)
Mounting
Wall mount in clean, protected area
Ambient Temperature
30°F – 100°F (-1°C – 38°C)
SECTION 2 Installation
2A. Recommended Installation for wells & holding tanks
Refer to Figure 1 (Next Page)
1. The ZO-400 must be securely mounted to a clean surface
sheltered from direct exposure to the elements (rain, sun
and dirt). Mount above the maximum water level, if possible.
Mounting hardware is not included.
2. Attach the check valve and tubing assembly to the barb fitting
coming out from the bottom right side of the ZO-400. Make sure
the flow arrow on the check valve points away from the ZO-400
and toward the water tank. Soften the tubing if necessary by
dipping it in warm water.
3. Connect one end of the tubing supplied in the parts bag to the
larger end of the check valve and tubing assembly. Connect the
other end of the tubing to the dispersion stone.
4. Place the Dispersion Stone into the center of the water vessel
approximately 1 foot from the bottom for maximum ozone
saturation in the water. It is best to put a sinker weight on
the stone to keep it from floating up and use string to keep it
from sinking all the way to the bottom of the tank. Note: The
Dispersion Stone is delicate. Be sure to place it where it will not
be stepped on or crushed.
5. If the generator is mounted below the water line, a water trap
loop must be used. To make a water trap loop, simply coil the
tubing into a 6" circle, (
Figure 1), and fasten it above the water
line. The plastic check valve provided should be installed in the
ozone supply tubing between the generator and the loop, and
secured with tubing clamps. Be sure that the flow arrow on the
check valve points toward the tank.
CAUTION: Small amounts of nitric acid may collect in the
ozone supply tubing during normal operation. When servicing
or replacing tubing wear proper safety equipment and avoid
bodily contact with
condensation.
Figure 1: Recommended Installation
Aquaclipse Ozone Generator
WATER IN
TANK
STRING
WATER TRAP LOOP
CHECK VALVE
WEIGHT
OZONE DISPERSION STONE
WATER OUT
AQUACLIPSE
GROUND FAULT CIRCUIT
INTERRUPTOR