background image

2

3

Aquaclipse 

Installation & Operations Manual

Aquaclipse 

Installation & Operations Manual

What's in the box?
1. Aquaclipse Ozone Generator
2. Parts Bag
 (P/N 9-1190-01)

a. Squeeze Clamp (P/N 7-0021)
b. Squeeze Clamp x2 (P/N 7-1453-

01)

c. Check Valve & Tubing Assembly  

(P/N 9-0796-01)

d. 3/8" ID Tubing (P/N 7-1430-01)
e. Manual (P/N 4-2191-01)
f.  Dispersion Stone (P/N 7-1513-01)

1B. Specifications 

Compressor Flow
15 SCFH @ 10 psi

Power Requirements
ZO-400:   

120VAC, 60Hz, 1Ø, 2.3A

ZO-400-25 : 

230VAC, 50Hz, 1Ø, 1.3A

Shipping Weight
ZO-400:   

25 lbs. (11.6 kg)

ZO-400-25 : 

26 lbs. (11.8 kg)

Mounting
Wall mount in clean, protected area

Ambient Temperature
30°F – 100°F (-1°C – 38°C)

SECTION 2 Installation

2A. Recommended Installation for wells & holding tanks

Refer to Figure 1 (Next Page)
1. The ZO-400 must be securely mounted to a clean surface 

sheltered from direct exposure to the elements (rain, sun 
and dirt). Mount above the maximum water level, if possible.  
Mounting hardware is not included.

2. Attach the check valve and tubing assembly to the barb fitting 

coming out from the bottom right side of the ZO-400. Make sure 
the flow arrow on the check valve points away from the ZO-400 

and toward the water tank. Soften the tubing if necessary by 
dipping it in warm water.

3. Connect one end of the tubing supplied in the parts bag to the 

larger end of the check valve and tubing assembly. Connect the 
other end of the tubing to the dispersion stone.

4. Place the Dispersion Stone into the center of the water vessel 

approximately 1 foot from the bottom for maximum ozone 
saturation in the water. It is best to put a sinker weight on 
the stone to keep it from floating up and use string to keep it 
from sinking all the way to the bottom of the tank. Note: The 
Dispersion Stone is delicate. Be sure to place it where it will not 
be stepped on or crushed.

5. If the generator is mounted below the water line, a water trap 

loop must be used. To make a water trap loop, simply coil the 
tubing into a 6" circle, (

Figure 1), and fasten it above the water 

line. The plastic check valve provided should be installed in the 
ozone supply tubing between the generator and the loop, and 
secured with tubing clamps. Be sure that the flow arrow on the 
check valve points toward the tank.

CAUTION: Small amounts of nitric acid may collect in the 
ozone supply tubing during normal operation. When servicing 
or replacing tubing wear proper safety equipment and avoid 
bodily contact with
condensation. 

Figure 1: Recommended Installation

Aquaclipse Ozone Generator

WATER IN

TANK

STRING

WATER TRAP LOOP

CHECK VALVE

WEIGHT

OZONE DISPERSION STONE

WATER OUT

AQUACLIPSE

GROUND FAULT CIRCUIT 

INTERRUPTOR

Отзывы: