DEKKER Vacuum Technologies, Inc. / Part No. 9983-0000-E02 / September 2019
18
SCAVENGER OUTPUT
Output 6 on the controller is used for a bleed valve. This output cycles on for 30 Secs and off for 9 minutes based
on vacuum level. The vacuum level for cycling to occur is adjustable via the Setpoint menu on the Dekker
Controller.
•
Enter password
•
Press PROG until Setpoints screen is shown.
•
Using DOWN arrow scroll to SCAV LVL
•
Press ENTER
•
Use UP/DOWN arrows to change value
•
Press ENTER to save.