![Dekeghel CPM 100 Скачать руководство пользователя страница 21](http://html.mh-extra.com/html/dekeghel/cpm-100/cpm-100_instruction-manual_2465452021.webp)
Instruction manual for spiral mixer mod. CPM80-200
4.4
Preliminary operations
CHECK IF THE MACHINE HAS BEEN DAMAGED DURING TRANSPORT
Check the condition of the machine taking a close look at the outside and the inside.
Any deformation of the visible parts indicates that the machine has been hit by
something during transport. This could lead to malfunctioning.
Check the tightening of screws, bolts and fittings.
If damage has occurred
Damage caused by transport should be attributed to the carrier and the manufacturer
or its agent should be informed immediately of the situation.
Cleaning of the machine
•
Remove the dust and dirt deposited on the surface during transport.
•
Carefully clean and dry each part ( varnished or unvarnished ) using soft, clean
and dry cloths.
ATTENTION:
It is strictly forbidden to climb onto the box pallets and/or to stow
them one on top of the other.
•
Should the box pallets remain outdoors for some time, waiting to transported
inside the building, these box pallets should be covered with adequately-sized
waterproof tarpaulins.
•
If storage exceeds 3 months the box pallets should be stored inside, sheltered
from bad weather and protected from excessively high or low temperatures.
•
If the machine is unpacked, it should be covered in order to prevent the build-
up of dust and dirt.
4.5
Installation
Features of the installation site
A suitable installation site should be chosen considering the overall dimensions of the
machine, supplied in chapter 3.1 “specifications” at page 17, and in compliance with
the following rules :
•
The power supply source, in compliance with the power supply details given on
page 17, should be near the installation site.
•
Nothing should hinder the free movement of the operator around the
machine. The machine should be situated at least 1 metre from the nearest
wall or object.
•
Cabinets should be accessible at all times and the doors should open wide
without obstacle.
•
Make sure there is sufficient space for machine operation and maintenance
and also for any other additional equipment.
Protection against external atmospheric agents
The machine should be installed in a covered building, shielded from direct contact
with atmospheric agents.
21