DESIGNER’S HANDBOOK 4189350049C EN
Page 196 of 206
XDi units in this system are all multi-versions, but if there is no need for set point (orange), the Dual version can be
used instead.
13.3.1.1
Normal analogue azimuth and RPM
XDi
device
Selected
azimuth
indicator
CAN TX
azimuth angle
Control sys.
RPM/%RPM *
Select
VS profile
Actual
Set point
Actual
Set point
XDi 1
VI007
4-20 mA
4-20 mA
4-20 mA
4-20 mA
VS04
XDi 2
VI007
XDi-net
XDi-net
XDi-net
XDi-net
VS01
XDi 3
VI007
XDi-net
XDi-net
XDi-net
XDi-net
VS01
13.3.1.2
SIN/COS azimuth angle and normal analogue RPM
XDi
device
Selected
azimuth
indicator
CAN TX
azimuth angle
Control sys.
RPM/%RPM *
Select
VS profile
Actual
Set point
Actual
Set point
XDi 1
VI007
sin cos
4-20 mA
4-20 mA
0 to 10 V*
VS05
XDi 2
VI007
XDi-net
XDi-net
XDi-net
XDi-net
VS01
XDi 3
VI007
XDi-net
XDi-net
XDi-net
XDi-net
VS01
*) sin cos requires two analogue inputs, and therefore voltage input 3 (dimmer) on the second AX1 module (slot
2) is used as RPM set point input. (Voltage input 3 (dimmer) on AX1 in slot 1 is always reserved for dimmer in the
DEIF standard libraries).
13.3.2
Azimuth, Pitch and RPM system with set point
The same CAN/analogue system is now set up to support azimuth angle, pitch% and RPM/RPM%, all with set
point if required.
In this example, it is VI015 Pushing azimuth type with dynamic azimuth pointer, indicating RPM/RPM% and
+/- %Pitch.
(Orange set points can be disabled from menu).
All XDi units in this system must be the multi-version.