IMD 100 Integration manual 4189360015 Rev. G
Electrical HW connections and requirements
Page 45 of 243
Pitch motion controller or
main controller
IMD 1
CAN connector
2 (CAN low)
3 (CAN GND)
4 (CAN TR1)
6 (CAN GND)
7 (CAN high)
8 (CAN TR2)
60
Ω
60
Ω
IMD 2
CAN connector
2 (CAN low)
3 (CAN GND)
4 (CAN TR1)
6 (CAN GND)
7 (CAN high)
8 (CAN TR2)
60
Ω
60
Ω
IMD 3
CAN connector
2 (CAN low)
3 (CAN GND)
4 (CAN TR1)
6 (CAN GND)
7 (CAN high)
8 (CAN TR2)
60
Ω
60
Ω
Termination
Built-in termination
Built-in termination
Built-in termination
IMD 1
and
IMD 2
IMD 3
CAN high
CAN low
CAN GND
1
5
6
9
1
5
6
9
Figure 28
CAN connections
The CAN wires are connected to a male 9 pole D-sub connector as follows:
Terminal no.
Terminal text
Description
1,9
Not connected
2
CAN-L
CAN low
3, 6
CAN-G
CAN GND
4
CAN-T1
CAN termination resistor T1
Attention
Shields must be connected to the D-sub connector housing (see section
on page
) unless they carry the CAN GND. See also general shielding
and lightning protection in section
The CAN GND must be connected in one, and one place only to PE.