IMD 100 Integration manual 4189360015 Rev. G
Parameter description
Page 208 of 243
13.2.9 Logic in block (9B)
See also general definition of the parameter in the
Table 40
Reg. ID 0x9B, CANopen Object ID 209B
Bit
Short symbol
Description
Bit 0
RFE
0: disable the IGBTs by hardware, 1: enable operation
Bit 1
RUN
0: motor drive is disabled, 1: motor drive is enabled
Bit 2
LS_1
0: limit switch 1 is not activated, 1: limit switch 1 is activated
Bit 3
LS_2
0: limit switch 2 is not activated, 1: limit switch 2 is activated
Bit 4
DI1
0: Input is off, 1: input is on
Bit 5
DI2
0: Input is off, 1: input is on
Bit 6
DI3
0: Input is off, 1: input is on
Bit 7
DI4
0: Input is off, 1: input is on
Bit 8
DI5
0: Input is off, 1: input is on
Bit 9
DI6
0: Input is off, 1: input is on
Bit 10
DI7
0: Input is off, 1: input is on
Bit 11
DI8
0: Input is off, 1: input is on
Bit 12
DI9
0: Input is off, 1: input is on
Bit 13
DI10
0: Input is off, 1: input is on
Bit 14
DI11
0: Input is off, 1: input is on
Bit 15
DI12
0: Input is off, 1: input is on
Bit 16
SCI1
0: Input is off, 1: input is on
Bit 17
SCI2
0: Input is off, 1: input is on
Bit 18
X7 high
0: No voltage in X7, No power to brake output, 1: 24 V on X7
Bit 19
Not used
Bit 20
REGEN_25pc
Ballast load >= 25%
Bit 21
T_IGBT_60
Temp IGBT >= 60°C (hysteresis: off <55°C)
Bit 22
Not used
Bit 23
FAN
0: Fan not turning.
1: Fan turning.
Bit
24..27
SWITCH
Address of CAN ID switch on the front of the IMD (0 to 15)
Bit 28
BRK_OK
Indication of the brake connection status.
0: Impedance not within the expected range. Brake might not be
connected, or another brake type is used.
1: Brake is connected.
Bit 29
MAIN_OFF
0: Mains OK.
1: No mains present or IMD in grid-off mode.