DPS-1 Installation and operation instructions 4189360002 Rev. C 

Introduction 

www.deifwindpower.com 

Page 4 of 14 

1.

 

Introduction 

This document describes how to install and operate the DPS-1. The document is intended for 
persons responsible for integration of the DPS-1 in a pitch system, cabinet design, installation 
and operation.  
For detailed information about specifications and functions of the DPS-1, refer to DPS-1 
datasheet. 

It is recommended to print this manual in colour in order to get most information out of the 
pictures and illustrations. 

1.1

 

Revision history 

Apart from editorial changes the following changes have been made in this revision: 

Date 

Revision  Changes 

2017-06-27 

Total revision of document content. 

2012-12-14 

New document 

N/A 

Not used 

1.2

 

Conventions 

The following conventions are used in this document: 

Used in document 

Description 

 

A yellow symbol that illustrates hazard type (this symbol is an example for 
general hazard). There are different types such as electrical, chemical and so 
on. 

Danger! 

A signal word used to indicate an imminently hazardous situation, which if not 
avoided, will result in death or serious injury. (ISO 3864) 

Warning! 

A signal word used to indicate an imminently hazardous situation, which if not 
avoided, could result in death or serious injury. (ISO 3864) 

Caution! 

A signal word used to indicate a potentially hazardous situation, which if not 
avoided, could result in minor or moderate injury. (ISO 3864) 

 

A blue symbol illustrates a need for mandatory action. In this example read 
instructions. Other types of blue symbols exist and always indicate mandatory 
action. 

 

A symbol used to draw attention to extra information or an action that is not 
mandatory 

 

 

 

Содержание DPS-1

Страница 1: ...AND OPERATION INSTRUCTIONS Power supply DPS 1 Document no 4189360002 Rev C Date 2017 06 27 Language EN GB DEIF A S Frisenborgvej 33 DK 7800 Skive Tel 45 9614 9614 Fax 9614 9615 Info deif com www deifw...

Страница 2: ...this document is the original language and always contains the most recent and up to date information about the product Translations might not be updated at the same time as the English version DEIF...

Страница 3: ...3 1 Package content 6 3 1 1 Standard package content 6 3 2 Required tools and accessories 6 3 3 Handling 6 4 Mechanical mounting 8 4 1 DIN rail mounting 9 4 2 Chassis mounting 9 5 Electrical connectio...

Страница 4: ...N A A Not used 1 2 Conventions The following conventions are used in this document Used in document Description A yellow symbol that illustrates hazard type this symbol is an example for general haza...

Страница 5: ...be grounded if possible in order to protect the units and the persons working with them During normal operation the persons working with the units must have no contact to dangerous voltages within th...

Страница 6: ...nect wires Wire insulation stripping tool N A Strip wires insulation Press tool for ferrules N A Press ferrules on wires Ferrules recommended N A Terminate wires to connectors recommended different si...

Страница 7: ...Package content tools and handling www deifwindpower com Page 7 of 14 Sufficient care must be taken to protect the terminal against electrostatic discharges during the installation Once the unit is in...

Страница 8: ...02 Rev C Mechanical mounting www deifwindpower com Page 8 of 14 4 Mechanical mounting 150 154 120 70 141 107 116 78 8 Figure 1 DPS 1 2405 mechanical drawing The DPS 1 can be mounted on a 35 mm DIN rai...

Страница 9: ...d and hearing protection Use protection for eyes hand and hearing if the mounting holes for bolts need to be made during installation Drill six 4 mm holes according to Figure 2 on page 9 and the cabin...

Страница 10: ...of 14 5 Electrical connections 5 1 Connection diagram The following figure shows the connections to the DPS 1 Protective Earth input 1 2 3 DC OK DC OK 24V DC Out 5 4 6 7 8 DPS 1 Figure 3 Connection di...

Страница 11: ...ires to connectors Table 2 Technical data for all connectors D ZFKDS 2 5 Conductor cross section flexible without ferrule 0 2 to 2 5 mm2 Conductor cross section flexible with ferrule without plastic s...

Страница 12: ...s the double current or double length will also double the voltage drop Example 1 5 mm2 5 m 5A V 0 6 V Setting 24 0 0 6 24 6 V 6 2 Visual and electrical monitoring DPS 1 has two monitoring types Elect...

Страница 13: ...nt Waste electrical and electronic equipment WEEE must therefore be disposed of properly In Europe the disposal of WEEE is governed by the WEEE directive issued by the European Parliament DEIF complie...

Страница 14: ...urrent C degrees Celsius Temperature F Fahrenheit 32 5 9 g gram Weight oz ounce 1 g 0 03527 oz Hz hertz Frequency cycles per second kg kilogram Weight lb pound 1 kg 2 205 lb m metre length ft foot or...

Отзывы: