4.  Adjustment and control 

As the instrument is linearized to a max. indication error of 0.5% corresponding to a 
max. deviation of ±1.8° over the entire scale curve of 360°, it is not provided with an 
adjustment device. For control of deflection (indication) as a function of input the table 
below can be applied. 
 
Single input: 
 

Measuring 
range 

Input A 

Input B 

Disc position 

in degrees 

Clock position  

of disc 

 4.00mA 

 

  12 

 8.00mA 

 

90 

 

 12.00mA 

 

180 

 

 16.00mA 

 

270 

 

4...20mA 

 

(Disc moves 
CW with posi-
tive input) 

 20.00mA 

Not connected 

 360 

  12 

 0.00mA 

 

  12 

 0.25mA 

 

90 

 

 0.50mA 

  180 

 

 0.75mA 

  270 

 

0...1mA 

 

(Disc moves 
CW with posi-
tive input) 

 1.00mA 

Not connected 

 360 

  12 

 -10.00V 

 

  12 

 -5.00V 

  90 

  3 

 0.00V 

 180 

  6 

 +5.00V 

  270 

 

-10...0...10V 

 

(Disc moves 
CW with posi-
tive input) 

 +10.00V 

Not connected 

 360 

  12 

  
 
Double input (SIN/COS): 
 

Measuring  
range 

Input A 

SIN 

Input B 

COS 

Disc position 

in degrees 

Clock position 

of disc 

 12.0mA 

 20.0mA 

  0/360 

 

12 

 20.0mA 

 12.0mA 

 

90 

 

 12.0mA 

  4.0mA 

 

180 

 

4...20mA 

 4.0mA   

12.0mA    270 

 

 0.5mA   1.0mA   0/360 

  12 

 1.0mA   0.5mA   

90 

 

 0.5mA   0.0mA    180 

 

0...1mA 

 0.0mA   0.5mA    270 

 

 0.0V  

+10.0V  

0/360   12 

 +10.0V 

 

0.0V 

 

90 

 

 0.0V  

-10.0V  180    6 

-10...0...10V 

 -10.0V    0.0V    270 

 

  
 
 
 

Содержание DLQA96

Страница 1: ...n with disc pointer Linearized to class 0 5 LED illumination of scale and disc 100 identical illumination of scale and disc Shock resistant up to 50 g Enclosure IP52 54 or IP66 only Q96 size Approved...

Страница 2: ...6 0 69 0 68 3 19 19 19 90 x 90 136 x 136 90 x 90 103 150 103 12 12 12 92 x 92 0 8 137 x 137 1 0 92 x 92 0 8 0 230 0 385 0 250 The instrument is mounted by means of the 2 fixing elements For instrument...

Страница 3: ...from ESD is needed When the instrument is mounted in the console switchboard the terminal on the rear side is connected to the cable The instrument is configured either for single input or for double...

Страница 4: ...00mA 180 6 16 00mA 270 9 4 20mA Disc moves CW with posi tive input 20 00mA Not connected 360 12 0 00mA 0 12 0 25mA 90 3 0 50mA 180 6 0 75mA 270 9 0 1mA Disc moves CW with posi tive input 1 00mA Not co...

Страница 5: ...gle May be mounted at any angle between 0 360 to horizontal without this affecting the linearity according to DIN 16257 Compass safety distance To be mounted at least 1m from the compass according to...

Страница 6: ...3 2 100Hz 0 7 g according to DNV Class A Safety 300V cat III pollution degree 2 according to EN 61010 1 Galv separation 500V between all groups Supply voltage Power supply 24V DC 25 30 18 24 31 2V DC...

Страница 7: ...t consump DLQA96 144 12mA 24V DC Galv separation 500V 50Hz 1 min between groups 3 groups If protection against voltage transients surge pulse for the auxiliary supply AUX 24V and input for ILLUM is re...

Отзывы: