1. Remove the rubber gasket
To remove the rubber gasket, gently push it towards the center of the record insertion slot.
Once the gasket is loosened you can pull it off the machine.
Страница 1: ...Degritter water level sensor cleaning guide Requirements Toothbrush Degritter RCM ...
Страница 2: ...1 Remove the rubber gasket To remove the rubber gasket gently push it towards the center of the record insertion slot Once the gasket is loosened you can pull it off the machine ...
Страница 3: ... Locate sensor pins When facing the machine look in side the ultrasonic tank and try to locate two metal pins sticking out at the bottom of the tank They are a bit to the left from the center of the tank ...
Страница 4: ...nsor pins Clean the sensor pins gently with a toothbrush A small amount of Degritter s cleaning fluid can be added to the brushes Once the pins are cleaned brush them once more with a toothbrush rinsed in clean water ...
Страница 5: ...re putting back the rubber gasket test the machine to verify that the sensor pins are clean and the machine is able to pump out water normally 5 Put back the gasket Once the sensor works as intended put back the rubber gasket ...