28
2.3.2 No rest mandrel discharge
Troubles and Causes
Remedy
Wrong nose piece
Change to correct
nose piece
Nose piece worn
Replace nose piece
Rest mandrel jammed in
clamps
Loosen the mandrel,
clean the clamps
assembly and lubricate
them
Mandrel collector full
Discharge the mandrel
collector and empty
Mandrel release tube
blocked
Remove the mandrel and
check for ejection
2.3.3 Warning light indicates faults
Troubles and Causes
Remedy
Clamps not return to the
start position
Release the trigger
Overloading
Check the rivet as per
tool working capacity
Overheating
Cool off the tool in the
air
Battery empty
Charge the battery, or
replace when needed