Note.This appliance is supplied ex-
factory with jets and air settings for use 
with LP gas only. 
 
Safety compliance with local 
requirements. 
 
Installer’s details are to be filled in on 
page 24 of this book 
 
 
Temporary installation 
 

Flexible hose connection from the gas 
appliance to the bottle can be made. 
Ensure that pipe clamps are tightened 
correctly and are of good quality. 
 

x

Flexible hose 

- Not supplied. 

Any hose that is used to connect the 

stove to the gas system shall comply with 
SANS 1156-2 or BS 3212. 

x

Gas bottle 

- Not supplied. 

For best results we recommend that gas 

cylinders with a minimum capacity of 19kg 
be used. 

x

Regulator

 - Not supplied. 

A 2.8-3.0 kPa LP gas regulator which 

complies with SANS 1237 must be used.

 

Permanent installation 
 
Important information for the user 
 
This appliance may only be installed by a  
registered LP Gas installer.  All registered 
installers are  issued with a card carrying 
their registration number.   
 
Ask to be shown this card before 
allowing the installation to commence 
and make a note of the installer QCC 
number on page 24 of this book.  
 

Upon completion  of the installation, the 
installer is required to explain the operational 
details of the appliance together with the 
safety instructions. You will be asked to sign 
acceptance of the installation and be 
provided with a completion certificate. You 
should only sign  for acceptance when the 
installation is completed to your satisfaction.  
 

Failure to comply with the above will 
render the warranty invalid. 
 
Note:  
 
Your invoice is required in the event  of 
you wishing to make a warranty claim. 

 

 

DANGER Risk of explosion and 
suffocation! 

The maximum 

bottle size allowed in the house 
is19 Kg

 

Содержание DHG701

Страница 1: ...Page 1 DHG701 4 BURNER GAS HOB ON GLASS Cooking Instruction manual Part number 071905D...

Страница 2: ...n on how to operate and care for your appliance to gain the maximum benefit from it We trust you will enjoy years of trouble free use EXPLANATION OF SYMBOLS Throughout this User Manual the following s...

Страница 3: ...the installer 10 Important information for the user 11 Electrical connection 12 Gas connection 12 Leakage control 13 Final check 14 Gas conversion 14 Package information 15 Future transportation 15 Di...

Страница 4: ...burner Rear right Overview The manufacturer strives for continuous improvement For this reason technical specifications text and illustrations in this manual are subject to change without notice Figu...

Страница 5: ...ifications may be changed without prior notice to improve the quality of the appliance Figures in this manual are schematic and may not exactly match your appliance Values stated on the appliance labe...

Страница 6: ...using alcoholic drinks in your dishes Alcohol evaporates at high temperatures and may cause a fire since it can ignite when it comes into contact with hot surfaces x Do not use the appliance for heati...

Страница 7: ...itchen is well ventilated keep natural ventilation holes open or install a mechanical ventilation device mechanical extractor hood Prolonged intensive use of the appliance may call for additional vent...

Страница 8: ...he safety of the occupants in the room in which the appliance is installed Intended use This appliance is designed for domestic use Commercial use will void the warrantee CAUTION This appliance is for...

Страница 9: ...650 mm x Remove packaging materials and transport locks x Surfaces synthetic laminates and adhesives used must be heat resistant 100 C minimum x The worktop must be aligned and fixed horizontally x Cu...

Страница 10: ...ant information for the installer This appliance may only be installed by a registered LP Gas installer registered with the LPGSASA Liquefied Petroleum Gas Association of Southern Africa The appliance...

Страница 11: ...installation Important information for the user This appliance may only be installed by a registered LP Gas installer All registered installers are issued with a card carrying their registration numb...

Страница 12: ...turer shall not be held responsible for damages arising from procedures carried out by unauthorized persons Plug the power cable into the socket Gas connection DANGER Risk of explosion or poisoning by...

Страница 13: ...e on the gas bottle x Check and tighten the connections immediately x Repeat the procedure to ensure that there are no further leaks Installing the appliance 1 Remove burners burner caps and grills on...

Страница 14: ...nt screw position may vary 1 Flow rate adjustment screw Final check 1 Open gas supply 2 Check gas installations for secure fitting and tightness 3 Ignite burners and check appearance of the flame Gas...

Страница 15: ...s and pan supports with adhesive tape Check the general appearance of your appliance for any damages that might have occurred during transportation Disposing of the old product Dispose of the old appl...

Страница 16: ...rrect pot size for your dishes Larger pots require more energy Initial use First cleaning of the appliance The surface may get damaged by some detergents or cleaning materials Do not use aggressive de...

Страница 17: ...aluminum vessels on it x Such vessels should not be used to keep foods in either x Use flat bottomed saucepans or cooking vessels only x Put only the appropriate amount of food in saucepans and pans...

Страница 18: ...f the gas valves Gas valves must be controlled from 90 to 210 or 160 according to the gas valve model If flame is set from 0 to 90 the burner will be below the minimum output and may result in a flash...

Страница 19: ...down before you clean it Sugar based foods such as thick cream and syrup must be cleaned promptly without waiting the surface to cool down Otherwise glass ceramic surface may be damaged permanently G...

Страница 20: ...d remove the pot stands burner caps and burner bodies 1 Insert the socket into the central tube of the burner so that it locates over the brass gas jet at the bottom of the tube 2 Gently loosen the br...

Страница 21: ...The lighting procedure has not been followed correctly Follow the correct lighting procedure The flame is yellow Pots and pans are stained The burners are dirty or wet Clean dry the burner components...

Страница 22: ...vice defy co za Sub Saharan Africa Branches ZAMBIA SOUTHGATE INVESTMENTS LTD Plot 1606 Sheki Sheki Road P O Box 33681 Lusaka 10101 Zambia Tel 260 0211 242332 3 Fax 260 0211 242933 sgiservicecentre mic...

Страница 23: ...and attention in the use and maintenance of the appliance Abuse misuse in conflict with operating instructions connection to incorrect voltages and subjection to commercial use shall release the Comp...

Страница 24: ...uct at www defy co za Installer s details to be recorded below INSTALLER S NAME AND COMPANY INSTALLER S REGISTRATION NUMBER HAVE YOU RECEIVED A WRITTEN COMPLETION CERTIFICATE HAS THE INSTALLER EXPLAIN...

Отзывы: