Cooker Hood / User Manual
9 / EN
3
Operation of the Appliance
3.5 Operation with Flue Connection
•
Vapour is extracted through the
flue duct, which is fastened to the con-
nection head on the hood.
•
The diameter of the flue duct must
be the same as the connection ring. In
horizontal settings, the pipe has to have a slight up-
ward slope (around 10º) so that the air can exit the
room easily.
3.6 Operation without Flue
Connection
•
Air is filtered through the carbon
filter and recirculated in the room. Car-
bon filter is used when it is impossible
to use a flue in the house.
•
In flueless use, remove the flaps
inside the flue adapter.
•
Remove the Grease Filter . To install the carbon filter,
fit the filter to the tabs by centring it on the plastic
piece on both sides of the fan body. tighten it by turning
right or left.
•
Replace aluminium Grease Filter .
Bulb
Bulb Power (W)
3
Holder / Socket
E 14
Bulb Voltage (V)
220 - 240
Size (mm)
35 x 100
ILCOS Code
DRBB/F-3-220-
240-E14-35/100
A
CAUTION
Disconnect the electrical supply of the
hood. Leave the lamps to cool down first
because they could burn your hands
when they are hot.
•
Remove the aluminium cartridge filter. Remove the de-
fective bulb and replace with a new one with the same
rating (Figure 4).
3.4 Replacement of Lamp
(Figure 4)
MAX
3 W