background image

5

 

 

1.

 

INFORMATION 

Operating manual is an integral and essential part of the product 

and must be forwarded to the user also in the case when the property 

is transmitted. User should carefully read the manual and save it for the 

future because all remarks included there are important guidelines con-

cerning safety during installation, usage and maintenance.  

Installation of the dry stove must be carried out in accordance with 

the mandatory standards in the country of destination, according to 

guidelines of the manufacturer and by qualified personnel. Improper 

installation of the device can be a reason for personal injuries and dam-

age to property for which the manufacturer is not liable.  

The dry stove can be used only for the purpose it was explicitly 

intended. Any other use should be treated as inappropriate and in con-

sequence as dangerous. 

In case of error during installation, usage or maintenance works 

caused by non-observance of the legislation, regulations in force or in-

structions contained in this manual (or others, delivered by the manu-

facturer) the manufacturer rejects any contractual or non-contractual 

liability for resulting damages and the warranty for the device becomes 

void. 

Versions of the publication 

Due to the continuous improvement of the product, DEFRO re-

serves the right to update this publication without prior notice. 

Content of this Operating Manual is a property of DEFRO. Any 

copying, duplicating, publishing of content of this User’s Manual without 

the prior written consent of DEFRO is forbidden. 

Manual storage and browsing its contents

 

We recommend to take care of this manual and store it in an easily 

and quickly available location. If this manual has been lost, damaged 

or destroyed you should request a copy in the sales outlet or directly 

from the Manufacturer providing identification data of the product. All 

the most important information included in the operating manual are 

marked with “bold” and have symbols pointing out user’s attention to 

hazards which can be present during operation of the dry stove. Sym-

bols used in the text are explained below:  

 

Danger! 

A direct threat to life and health! Non-compliance with the 

recommendations marked in this way and misuse may 

result in death or major injuries. 

 

Danger! 

Danger from electrical voltage! Incorrect installation and 

incorrect electrical connections may cause danger to life 

by electric shock. 

 

Note! 

Warning symbol indicating that you should read carefully 

and understand the given information, to which it relates. 

Non-compliance with these recommendations may result 

in major damage to the equipment and create a hazard 

for the user or the environment. 

 

Danger! 

A direct threat to health! Non-compliance with the recom-

mendations distinguished in this way may cause a fire or 

burns. 

 

Hint! 

Informative symbol. Useful information and hints are 

marked in this way. 

2.

 

BASIC SAFETY RULES 

2.1.

 

SAFETY WARNINGS 

 

 

The national and local provisions should be met. 

 

Equipment should be installed in compliance with the 
legal standards applicable in the given location, region 

or country.  

 

The equipment should be used by a person (including 
children) of impaired physical, sensory, mental capa-

bilities  and by persons without experience and re-

quired knowledge provided that such operation is not 

carried out under their supervision or after proper in-

struction by a person responsible for their safety. 

 

You should always observe the guidelines given in the 

operating manual to ensure the correct use of the 

equipment and to prevent accidents. 

 

Operation and adjustment should be carried out by 
adults. Errors and incorrect setting can cause hazard-

ous situations and/or incorrect operation. 

 

Prior to any operations the user (or any person oper-
ating the equipment) should read and understand 

whole contents of this manual.  

 

Equipment should be used only as intended. Each 

other use is considered as misuse and hazardous as 

a consequence. 

 

The equipment should not be used as a ladder or ob-
ject to lean against. 

 

Prior to installation, you should make sure that the 
substrate will resist the force of the equipment consid-

ering its weight. 

 

In case of disturbances in operation, the equipment 

can be restarted only when the occurred problem has 

been removed and the equipment is brought back to 

original condition. 

 

The user is fully responsible for misuse of the product 
and relieves DEFRO from any civil and criminal liabil-

ity. 

 

All types of modifications or replacement of equipment 
parts with non-original components or without authori-

zation may present a risk for the operator and relieve 

DEFRO from any civil and criminal liability. 

 

Incorrect installation or maintenance (incompatible 

with contents of this manual), can cause injuries of 

people, animals or property damage. Then DEFRO 

shall be relieved of any civil or criminal liability. 

 

 

 

Part of the equipment surface is very hot (doors, han-
dle, window panel, flue gas discharge pipe, etc.). You 

should avoid direct contact with such components 

without suitable protective clothing or protective equip-

ment such as e.g. heat resistant gloves. 

 

Do not touch the window panel after heating up of the 
equipment. 

 

Keep children away from the equipment when it is op-

erating because each hot surface can cause burns. 

 

It is forbidden to start-up the equipment when the 
doors are opened or the window panel is cracked. 

 

Do not place and dry the underwear on the equipment. 
Possible dryers for hanging underwear or similar 

should be located at an adequate distance from the 

equipment - fire hazard. 

 

It is absolutely forbidden to open the doors if the flue 

is on fire. Then call the appropriate services. 

 

It is recommended to keep a distance min. 400 mm 
between hot parts of the equipment and medium in-

flammable materials; otherwise use commercially 

available insulation materials. Apply this hint also for 

furniture, curtains etc. Minimum distances are given in 

point 5.2 of the operating manual. 

Содержание AQUAPELL

Страница 1: ...operating manual dry stove with water system fired with pellet DEFRO HOME AQUAPELL 13 kW translation of original operating manual issue 4 July 2020...

Страница 2: ...i by przekazana wraz z piecem kominkowym w przypadku odst pienia w asno ci innej osobie This Declaration of Conformity becomes invalid if any changes have been made to the Dry Stove if its constructio...

Страница 3: ...of the Warranty Card to the following address DEFRO Sp z o o Sp k Centrum Serwi sowe Ruda Strawczy ska 103a 26 067 Strawczyn fax 41 303 91 31 serwis defro pl By sending back your Warranty Card you wil...

Страница 4: ...2 7 CLEANING AND MAINTENANCE 12 7 1 1 Water system 12 7 2 Basic operations and cleaning by the user 12 7 2 1 Cleaning before each starting 12 7 2 2 Every day service 13 7 2 3 Every week service 13 7 2...

Страница 5: ...in this way 2 BASIC SAFETY RULES 2 1 SAFETY WARNINGS The national and local provisions should be met Equipment should be installed in compliance with the legal standards applicable in the given locati...

Страница 6: ...perties compatible with the rec ommendations of this operating manual Check and clean flue gas discharge ducts a connect ing piece to flue periodically Store this manual carefully because it should be...

Страница 7: ...er are given in brackets 2 Device weight depends on the selected design version and its equipment 3 The stove is factory adapted for combustion of pellet with a diameter of 6 mm pellet with a diameter...

Страница 8: ...and if they are in good technical condition 5 2 WORKING ENVIRONMENT Dry stove should be installed in compliance with the re quirements of thecurrentlyapplicablestandards and le gal regulations and de...

Страница 9: ...hermore the air intake should be directly connected with the room where the stove is to be installed protected with grille metal net or suitable cover not restrict ing minimum cross section located in...

Страница 10: ...automated which allows automatic stoppage of operation if the safe temperature of water is exceeded Dry stove is ready for operation in closed system because it is equipped with diaphragm vessel insta...

Страница 11: ...ith water should be carried our using installed fixtures for filling and emptying which should be located in the lowest point of the heating system This process should be carried out slowly in order t...

Страница 12: ...hich will disconnect supply from the stove and will prevent damage of the stove and central heating system 7 CLEANING AND MAINTENANCE All operations related to cleaning of all components should be car...

Страница 13: ...moval of dust from heat exchanger chamber if ash has been accumulated in the chamber it should be removed 7 2 4 EVERY MONTH SERVICE If the stove is used extensively then you should remove the soot fro...

Страница 14: ...d 8 TROUBLESHOOTING Some anomalies indicating irregularities in operation can occur during operation of the equipment It can be caused by incorrect instal lation of the equipment without observation o...

Страница 15: ...er subject of agreement dry stove under the condition that the product has been fully paid Due to suitable proven and unified standards of sales the war ranty covers only product purchased in authoriz...

Страница 16: ...free of charge The guarantor can charge the costs connected with warranty claim only incase when claim is not accepted as a result of statingcircumstances which are listedin points 17 and 18 men tione...

Страница 17: ...equipment operation by the service within 60 days from date of carrying out the repair DEFRO will issue appropriate invoice for replace ment repair of the subject component with enclosed expertise pro...

Страница 18: ...18...

Страница 19: ...vered as complete the device showed no failure during the first start up carried out by a service company has received the Operating Manual and equipment s installation manual with this Warranty Card...

Страница 20: ...20 14 CARRIED OUT WARRANTY REPAIRS AND MAINTENANCE No date fault description repaired element description of repairs comments Stamp and signature of Service 1 2 3 4 5 6 7 8 9 10...

Страница 21: ...vered as complete the device showed no failure during the first start up carried out by a service company has received the Operating Manual and equipment s installation manual with this Warranty Card...

Страница 22: ...22...

Страница 23: ...nician Way of fault removal Advice DESCRIPTION END OF COMPLAINT Name and surname of service technician Fault removal date Justness of complaint Duration of repair Fault defect has been removed the equ...

Страница 24: ...24...

Страница 25: ...nician Way of fault removal Advice DESCRIPTION END OF COMPLAINT Name and surname of service technician Fault removal date Justness of complaint Duration of repair Fault defect has been removed the equ...

Страница 26: ...26...

Страница 27: ...nician Way of fault removal Advice DESCRIPTION END OF COMPLAINT Name and surname of service technician Fault removal date Justness of complaint Duration of repair Fault defect has been removed the equ...

Страница 28: ...28...

Страница 29: ...29 19 REGISTER OF INSPECTIONS OF SMOKE DUCTS date stamp and signature of chimneysweep date stamp and signature of chimneysweep...

Страница 30: ...specification CO emission in combustion products 0 0098 0 0081 1 13 O2 122 mg m3 101 mg m3 1 13 O2 PN EN 14785 2009 OGC emission in combustion products 2 mg m3 4 mg m3 1 13 O2 Commission Regulation EU...

Страница 31: ...zy ska 103A PARAMETERS OF THE EQUIPMENT UNIT MODEL IDENTIFICATION MYPELL Energy efficiency class Direct thermal power kW 2 9 Indirect thermal power kW 10 2 Energy Efficiency Index EEI 134 Efficiency a...

Страница 32: ...509 702 720 509 577 900 DEFRO Sp ka z ograniczon odpowiedzialno ci Sp ka komandytowa 00 403 Warszawa ul Solec 24 253 Manufacturing plant Ruda Strawczy ska 103 A 26 067 Strawczyn tel 41 303 80 85 biuro...

Отзывы: