manualshive.com logo in svg
background image

 

MAINTENANCE NOTICE 

 

NM-275 

index 09  

Page 1/50 

  September 2021

 

Control unit Sorio

®

 

 
 
 
 
 
 

   

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 

www.definox.com 

 

 

Содержание Sorio

Страница 1: ...MAINTENANCE NOTICE NM 275 index 09 Page 1 50 September 2021 Control unit Sorio www definox com...

Страница 2: ...7162003 13 5 2 2 AS i 2EV or 3EV module Ref 7162004 14 6 AS i MODULE VERSIONS 15 6 1 Wiring to the AS i network 15 6 2 The AS i network 16 6 2 1 AS i power supplies 16 6 2 2 AS i address programming 1...

Страница 3: ...orio unit 2EV 38 9 4 Sorio unit 2EV spare parts list 39 9 5 Sorio unit 3EV 40 9 6 Sorio unit 3EV spare parts list 41 9 7 Sorio Box 1EV Double Effect Monostable or Bistable 42 9 8 Sorio 1EV Spare parts...

Страница 4: ...8 9 2 04 September 2020 42 G BEGAUD Add of cams and spacers for VDCI 95 with breakaway cylinder 05 October 2020 41 42 44 G BEGAUD 7162257 was 7162071 7162258 was 7162074 7162259 was 7009059 7162260 w...

Страница 5: ...This can result in less serious injuries or damage to the equipment Electricity can result in serious bodily injury or loss of life This can result in less serious injuries or damage to the equipment...

Страница 6: ...Poles 1EV AS i Cable gland 1EV AS i M12 connector 4 Poles 1EV IO Link M12 connector 4 Poles 2EV Digital Cable gland 2EV Digital M12 connector 8 Poles 2EV AS i Cable gland 2EV AS i M12 connector 4 Pole...

Страница 7: ...unit it is important to ensure that the mains supply is switched off that the air supply is closed and that the circuit is purged Disassembling the cover Turn the cover counterclockwise to bring the...

Страница 8: ...nect the wires connected to the module as well as those on the connector Disassembling the module Unscrew the fixing screws and washers from the module and remove the module Disassembling the solenoid...

Страница 9: ...xing screws Tightening torque 0 4 Nm or 4 kgf cm Note For units with 2 solenoid valves there is a sealing plate on location 3 To assemble and disassemble it follow the same steps as for the solenoid v...

Страница 10: ...connection diagrams provided in this manual Tighten the cable gland Reassembling the cover Same as the reverse of the disassembling Align the fin of the cover with the stopper and bring the cover into...

Страница 11: ...tal IO Link 1EV module Ref 7162001 Terminal number Description Digital With M12 connector 1 Power supply 24V V V Pin 1 brown 2 Power supply GND V V Pin 3 blue 3 PLC in com Status OK IO Link Pin 4 blac...

Страница 12: ...nergized n a Sensor 2 n a Pin 6 pink 6 PLC in Upper seat activated n a Sensor 3 n a 7 PLC in Lower seat activated n a n a n a 8 PLC out Activating SV1 n a Activating SV1 n a Pin 2 white 9 PLC out Acti...

Страница 13: ...r Description With M12 connector 1 solenoid valve Set up only 1 AS i supply AS i 24V Pin 1 brown 2 AS i supply AS i GND Pin 3 blue 3 IO Link Signal NC IO Link Pin 4 black Description Input table De en...

Страница 14: ...Signal NC NC NC IO Link Pin 4 black 21 24V Ext Sensor V EXT V EXT V EXT n a 22 GND Ext Sensor V EXT V EXT V EXT n a 23 PLC in Ext Sensor Signal EXT Signal EXT Signal EXT n a 31 24V Aux Sensor V AUX V...

Страница 15: ...nd 2 0 6 1 Wiring to the AS i network The connection to the AS i network 5 7008024 is established via an M12 1 lead and a vampire clip 3 plastic standard stainless steel optional The M12 connector can...

Страница 16: ...installed slaves I No of AS i modules x 0 092 gateway intensity 6 2 2 AS i address programming The AS i address for the module is programmed either via the AS i master PLC coupling gateway etc or via...

Страница 17: ...noid valve and 1 active sensor Electromagnetic compatibility Temperature operating storage transport 25 31 6 VDC 92 mA EN61000 6 2 EN61000 6 4 10 to 60 C 40 to 85 C Communication specifications Protoc...

Страница 18: ...intenance manual On the actuator disassemble the smooth square and the quick connect square 11a and replace them with a pierced plug 8b Mount the signalling unit on the NO actuator On the unit replace...

Страница 19: ...are 11a to the quick connector square 11b with a pneumatic tube 4 6 Connect the quick connector square 11 to the smooth square with a pneumatic tube 4 6 Wire the electric cables depending on the type...

Страница 20: ...g the connection diagrams provided in this manual Restore pressure on channel P using the right quick connector 7 7 3 2 On VDCI MC actuator Connect the quick connector square 11a to the quick connecto...

Страница 21: ...ction diagrams provided in this manual Restore pressure on channel P using the right quick connector 7 7 4 2 On VDCI MC actuator Connect the quick connector square 11a to the quick connector square 11...

Страница 22: ...l 1 Button Description LED column RGB LED Status mode OK S Depending on current mode Menu Auto setup A flashing Off Menu Manual setup M flashing Off Menu Tolerance T flashing Off Return to the Status...

Страница 23: ...Status menu 3 Press the button for at least 3 seconds to start the calibration The LED column stays fixed on the Auto menu and the upper RGB LED flashes yellow for the duration of the calibration To c...

Страница 24: ...Press the button for at least 3 seconds to save the position for valve idle The upper RGB LED lights up for a few seconds in the colour of the idle position The RGB LED then flashes with the colour f...

Страница 25: ...s for a few seconds in the colour of the upper valve pulse position 7 Deactivate the SV2 solenoid valve and wait until the movement of the valve stops 8 Activate the solenoid valve SV3 and when the lo...

Страница 26: ...Without position White Forced external signal colour 8 4 1 Changing RGB LED colour valve open valve closed 1 Press the button for at least 5 seconds to enter the colour change mode The colour RGB LED...

Страница 27: ...valve open Button Effect Led column RGB Led Change to off S off Change to white A White flashing Change to green M Green flashing Change to blue T Blue flashing Change to yellow S A Yellow flashing Ch...

Страница 28: ...tton several times until the desired lower valve pulse colour is found Choose the colour for idle Button Effect Led column RGB Led Change to off S Unlit Change to white A White flashing Change to gree...

Страница 29: ...ange to Unlit S Unlit Change to white A White flashing Change to green M Green flashing Change to blue T Blue flashing Change to yellow S A Yellow flashing Change to Cyan SM Cyan flashing Change to Vi...

Страница 30: ...tolerance is displayed on the front LED Press the button several times to change the tolerance until the desired one is found Button Effect LED column RGB LED Change the tolerance to 1 mm M Flash T st...

Страница 31: ...index 09 Page 31 50 September 2021 4 When the Tolerance LED is flashing confirm by pressing the button for at least 3 seconds The selected tolerance stays fixed for 1 second and the LED column returns...

Страница 32: ...ions are necessary to exit the Pigging mode Replacing a magnetic cam on the valve actuator Disconnecting the Auxiliary detector Restarting a calibration of the valve or doing a Factory Reset of the un...

Страница 33: ...Unlocking buttons The 2 buttons can be locked unlocked using the following combination Press 3 times the button in less than 2 seconds to lock unlock the buttons on the module When the button locking...

Страница 34: ...0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Example Warning Code 13 LED S M T CODE Feedback Warning Description LED 0 1 Status OK S 2 Automatic calibration mode A 3 4 Manual calibration mode M 5 Pigging mod...

Страница 35: ...e position was not reached in the allotted time 2 Lack of air or mechanical problem 3 Outside tolerance M E 21 Unexpected valve movement 1 Manual forcing 2 Shock loading S M E 22 External detector mis...

Страница 36: ...MAINTENANCE NOTICE NM 275 index 09 Page 36 50 September 2021 9 Sorio SPARE PARTS 9 1 Sorio unit 1EV 1 2a 3 2b 24 25 22 23 5 7 8 9 10 8 11 4c 18 12 14 15 16 17 13 19 20 21 6a a 6b 4a 4b 1a or or...

Страница 37: ...e gland 1 depending on configuration 7162139 6a M12 cord 3 pole 1EV 3EV AS i IO Link 1 depending on base Included in base 4b 6b 8 pole M12 cord 1EV Digital 1 depending on base Included in base 4c 7 6...

Страница 38: ...275 index 09 Page 38 50 September 2021 9 3 Sorio unit 2EV Exit A Exit B Cable gland 20 21 1 28 2a 2b 24 25 22 23 8 11 12 13 4c 4a 4b 3a 3 19 9 14 17 15 6 16 18 30 8 11 or 29 11 1a or 10 Exit A Exit B...

Страница 39: ...base 5b 6b 8 pole M12 cord 3EV Digital 1 depending on base Included in base 5c 7 6 straight snap fitting 1 7009065 8 1 8 Gas exhaust plastic plug 1 or 2 depending on configuration 7002496 9 O ring 1...

Страница 40: ...40 50 September 2021 9 5 Sorio unit 3EV Exit A Exit B Cable gland with upper valve pulse detector 1 3a 2a 2b 24 25 22 23 27 8 11 12 14 21 20 4c 4a 4b 3a 3 19 13 17 15 6 16 18 11 8 11 or or 1a or 9 10...

Страница 41: ...se Included in base 5c 7 6 straight snap fitting 1 7009065 8 1 8 Gas exhaust plastic plug 1 or 2 depending on configuration 7002496 9 O ring 1 7006064 10 O ring 1 7162075 11 Snap on square 6 3 or 4 de...

Страница 42: ...ct Monostable or Bistable 1EV Double Effect Bistable 1EV Double Effect Monostable or or 21 20 1 1a 24 25 22 23 2a 2b 3b 6a 4c 4a 4b 19 7 11 12 13 14 17 15 6 16 18 11 8 9 10 27 30 5 33 21 20 or or 1 1a...

Страница 43: ...onfiguration 7162155 5 M16 x 1 5 cable gland 1 depending on configuration 7162139 6a M12 cord 3 pole 1EV 3EV AS i IO Link 1 depending on base Included in base 4b 6b 8 pole M12 cord 3EV Digital 1 depen...

Страница 44: ...8 7162012 B M10 Open end spanner 17 50 M10 7162013 B M12 Open end spanner 17 50 M12 7162014 B M16 Open end spanner 17 51 M16 7162138 C M6 Female Allen key 2 5 2 Nm 72 M6 7162189 C M5 Female Allen key...

Страница 45: ...DN150 7162011 7162141 7162321 VDCI MC PFA DN38 DN51 7162201 See table 9 9 4 2 7162338 DN63 DN80 7162202 7162141 7162340 DN100 DN150 7162202 7162141 7162340 VDCI MC PFA without breakaway cylinder DN38...

Страница 46: ...r 83 34 18 7162212 G Base for VDCI VDE 95 DN125 150 actuator 118 25 5 15 7162211 H Base for DCX1 2 DN25 40 actuator Center distance 50 79 5 24 15 7162213 I Base for VDCI MC DN125 150 actuator 83 34 35...

Страница 47: ...M6 7162318 Spacer for actuator DCX3 4 BALANCED DN50 80 19 75 15 5 M6 7162319 Spacer for actuator DCX3 4 BALANCED DN100 24 9 15 5 M6 9 9 4 2 VDCI MC PFA DN Ref Sorio spacer VDCI MC PFA Height H Counte...

Страница 48: ...ember 2021 9 9 4 3 VDCI PFA 1991 1995 DN Ref Spacer VDCI 95 Diameter Height H Counterbore depth P DN38 51 7140016 Depth 2 mm 16 5 2 DN63 76 7140036 Depth 1 5 mm 24 6 5 1 5 DN80 104 7140158 Depth 1 8 m...

Страница 49: ...bles and vampire clips Reference Description Visual 7162169 Connector cable M12 0 6 m 7162017 Connector cable M12 1 m 7162170 Connector cable M12 2 m 7162165 Connector cable M12 5 m 7008227 Plastic Va...

Страница 50: ...NA DEFINOX Beijing Stainless Steel Equipment Ltd No 18 Anningzhuang East Road HAIDIAN District BEIJING 100085 CHINA Tel 86 10 6293 4909 Fax 86 10 6293 4835 lk definox com cn The technical characterist...

Отзывы: