8
Operation (continued)
2
Setting the sensor for testing
NOTE:
When the “LUX” control is set to the “ + ” position,
the light fixture will operate during the day or night. When
the “TIME” control is set to the “ – “ position, the light will
stay on for 10 seconds after all motion is stopped.
□
Grasp the motion sensor (C) housing and rotate
right or left to access the controls.
□
Set the “LUX” control to the “ + ” position.
□
Set the “TIME” control to the “ – ”
position.
□
Slide the “SENS” control to the “ – ”
position.
NOTE:
The motion sensor will need to completely warm
up (60 seconds) before beginning the setup process.
+
–
LUX
+
–
SENS
+
–
TIME
3
Adjusting the motion sensor
detection zone
□
Perform a “walk test”: walk in an arc across
the front of the motion sensor (C).
□
Watch the light. The light will come on
indicating motion has been detected.
□
Stop, wait for the light to turn off, and then
begin walking again.
□
Continue this process until the detection zone
has been established.
4
Adjusting the SENS control
□
To increase the detection zone, turn the
“SENS” dial toward the “ + ” position.
□
To decrease the detection zone, turn the
“SENS” dial toward the “ – ” position.
NOTE:
The motion sensor (C) is more sensitive to motion
moving across the front of the sensor. The motion sensor
(C) is less sensitive to motion moving directly toward the
front of the sensor.
NOTE:
The higher the “SENS” setting (sensitivity), the
greater the possibility of false triggering. To reduce false
triggering, turn the “SENS” dial toward the “ – ” setting.
LUX
+
–
+
–
SENS
+
–
TIME
C
C