background image

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 

www.defendertech.eu 
[email protected] 

Tel. +39 0721.1626113  

 Fax +39 0721.0731145 

 

 

 

 

 

Содержание DT-800Lan

Страница 1: ...Manual of installation and maintenance Fog Generators DEFENDERTECHDT 800Lan...

Страница 2: ......

Страница 3: ...e power supply of the appliance must be supplied through a special switch or plug in order to allow it to be switched off Danger of burns the components of the appliance are subject to heating do not...

Страница 4: ...ct then this will have to report their presence to the Producer on penalty of forfeiture within one week of discovery 4 The Customer provided that he has provided a timely description of the data cont...

Страница 5: ...igation to display The legislation provides for the obligation to post in the access route of the premises a notice that signals the presence of a Fog Generator Use the adhesive label supplied with th...

Страница 6: ...adjustable up to 200 mm Nozzles extension lengh adjustable up to 500 mm Fog jet diversion kit passes through the wall behind the equipment Fog jet split and diversion kit 50 passes through the wall be...

Страница 7: ...THE APPLIANCE Use 4 10 mm dowels fisher of the type suitable for the wall on which the machine will be installed If necessary it is possible to drill the bracket at any point of it adjacent to the wa...

Страница 8: ...2 Place the appliance on the front of the bracket and let the four fins of the bracket penetrate the side slits of the appliance operation 1 3 Slide the appliance down 2nd operation 4 Using a 4mm Alle...

Страница 9: ...Description DT 800Lan Control Card...

Страница 10: ...te This contact can be used to assign other functions see p 14 special features STATE system status failure signal When the appliance is disarmed or switched off the Clean NA contact normally open wil...

Страница 11: ...ording to the times programmed through the DipSwitch as shown in the table on page 13 If desired it is possible to change the contact activation mode to OPEN by turning ON the DipSwitch nr 3 Also ARM...

Страница 12: ...vating this function the Fog2 input takes on the task of preventing accidental firing If a negative signal is present on FOG2 the shot will not be allowed If the signal arrives while the shot is in pr...

Страница 13: ...X X X PUMP MODE CONTINUE X X X X X X X OFF X X IMPULSIVE DOUBLE THE SHOT TIME X X X X X X X ON X X RESISTANCE NUMBER 1 X X X X X X X X OFF OFF 2 X X X X X X X X ON OFF X X X X X X X X X X X X X X X X...

Страница 14: ...ORK SIGNALING OFF OFF X X X X X X X X LACK OF NETWORK SIGNALED ON STATE RELAY ON ON X X X X X X X X LACK OF NETWORK NON SIGNALED ON STATE RELAY LIQUID LEVEL CONTROL OFF X OFF X X X X X X X LIQUID LEVE...

Страница 15: ...nctions of the Menus 1 and 2 you will have to program them simultaneously starting from those of the menu 1 activate the DIP10 and then the DIP corresponding to the desired functions of the Menu2 DIP...

Страница 16: ...PAUSE STATE FIXED ON THE APPLIANCE IS IN THE FORCED PAUSE STATE it will ignore every firing commands untili its end ONE FLASH FOR EVERY RIARMAMENT OF THE MACHINE FAILURE LED6 RED TURNED OFF NO ALLARM...

Страница 17: ...on peaks especially if there are more Fogs Generators or there is only one that is turned on 24H SHOT MANAGEMENT The shot is inhibited when the appliance is unarmed the burner temperature is lower tha...

Страница 18: ...DT MultiFogControl is responsible for monitoring simultaneously the operating status of several Fogs Generators even in different geographical sites Both software can be requested free of charge by m...

Страница 19: ...s incorrect reset the error by operating the DipSwitch no 5 if it persists the appliance will not work until it is replaced by the service DefenderTech LACK_NETWORK_ALARM self restoring lack of electr...

Страница 20: ...re the liquid level to the 100 acting on DipSwitch nr 4 TECHNICAL INSTALLATION Once the machine is connected to the mains activate the buffer battery connecting the flying cable to the respective free...

Страница 21: ...following is prescribed to Replace the buffer batteries 2x12V 1 3 are wired in series Arm the appliance by measuring voltage and absorption on the 230V mains Perform a full 60 second shot using water...

Страница 22: ...1 DT 1600plus Lan 1601 DefenderTech Fog Generator Device Fog Genrator for safety applications They comply with the European Community Directives Low Voltage 2004 108 CE Electromagnetic Compatibily 200...

Страница 23: ...ion directive C E E HAZARD IDENTIFICATIONS No specific danger can be found in the use of the effects PHYSICAL AND CHEMICAL PROPERTIES Physical state liquid Appearance and color liquid of transparent c...

Страница 24: ...www defendertech eu info defendertech eu Tel 39 0721 1626113 Fax 39 0721 0731145...

Отзывы: