background image

Page 10

Calibration adjustments are returned to the Gage’s factory settings. The factory 
calibration icon will appear on the display. 

Menu settings are returned to the following:

Memory = OFF
Auto Sub-Batch = OFF
Statistics Mode = OFF
HiLo Alarm = OFF
Bluetooth & Stream = OFF
BLE Keyboard = OFF
WiFi & Access Point = OFF
USB Keyboard & Stream = OFF
Auto Dim  = ON
Hi Res = OFF

Perform a more thorough Hard Reset by powering down the Gage, waiting several 
seconds, then simultaneously holding both the center navigation and (+) buttons until 
the Reset symbol appears. This returns the instrument to a known, out-of-the-box 
condition. It performs the same function as a menu Reset with the addition of: 

Bluetooth Pairing info is cleared. Menu settings are returned to the following

Bluetooth Smart = OFF
Test Time = 1 second
Sound = Medium
Touch = ON
Flip Lock = OFF
Auto Sync .net = ON
USB Drive = ON
Language = English
Battery Type = Alkaline

NOTE:

Date, Time and WiFi are not affected by either Reset.

Battery Type

Selects the type of batteries used in the Gage from a choice of Alkaline, Lithium or 
NiMH (nickel-metal hydride rechargeable). The battery state indicator symbol is 
calibrated for the selected battery type. No damage will occur if the battery type used in 
the Gage does not match the selected battery type. 

Содержание PosiTector BHI

Страница 1: ......

Страница 2: ...nd touch the icon or press the button with the desired menu item selected For an overview of the use and operation of your instrument refer to its included Instruction Manual or download a digital PDF...

Страница 3: ...s 1 Pt Adjust Zero Cal Reset 2 Pt Adjust Setup Set Clock Reset Battery Type Sound Continuous Reading Touch Backlight Flip Lock Language Gage Info Hi Res Test Time Connect Bluetooth Enabled Stream Pair...

Страница 4: ...ngs AP Passphrase WiFi Reset WiFi Stream Auto Sync net Access Point Enabled Networks WiFi Information Sync net Now Bluetooth Smart Send Batches BLE Keyboard Smart Probes Power Off Time Enabled Sync Ba...

Страница 5: ...tch If it contains measurements on screen statistics will immediately reflect values calculated from this batch The calibration setting i e Cal 1 associated with this batch is also opened View Use the...

Страница 6: ...and B3 exist then B2 would be created and made the current batch Each measurement will be displayed and stored into this new batch On screen statistics are immediately updated with each measurement N...

Страница 7: ...Page 5 Batch Summary Displays a summary of all stored batches with the Batch Name Probe Type and Number of Readings listed for each batch...

Страница 8: ...o tabulations HiLo Alarm Allows the Gage to visibly and audibly alert the user when measurements exceed user specified limits When HiLo Alarm is selected the current Lo setting is displayed Adjust usi...

Страница 9: ...be verified with the included Test Disks and Leveling Plate Position the Leveling Plate under the Leg and place the Test Disks on a flat hard surface Take three to five readings on each disk The meas...

Страница 10: ...or foot and leg are resting on the glass plate After the last measurement the Gage will calculate a Zero which represents the average of all the Zero readings taken Cal Reset Restores the gage back to...

Страница 11: ...ector uses POSIX format to set the time zone Eastern Time in the USA is input as the following EST5EDT4 M3 2 0 M11 1 0 From left to right EST5 is the time zone name and offset from UTC EDT4 is the day...

Страница 12: ...ars This returns the instrument to a known out of the box condition It performs the same function as a menu Reset with the addition of Bluetooth Pairing info is cleared Menu settings are returned to t...

Страница 13: ...lects display brightness Sun Normal or Night If Auto Dim is enabled default the display dim slightly after a period of no activity to conserve battery life Press the Down button to brighten the displa...

Страница 14: ...osiTector BHI has an on screen timer to measure the hardness of a material after a given period of time Use the and buttons to adjust the test duration When taking a reading the timer starts automatic...

Страница 15: ...m individual readings to a USB connected computer via a serial protocol Ideal for use with serial compatible SPC data collection software See www defelsko com update Pairing The instrument and receivi...

Страница 16: ...ents with PosiSoft net USB Drive When USB Drive is enabled the PosiTector is recognized as a USB mass storage device which provides a simple interface to retrieve stored data in a manner similar to US...

Страница 17: ...s will automatically synchronize with PosiSoft net when connected to a computer running PosiSoft Desktop Additional measurements added to memory while connected are synchronized only when the USB cabl...

Страница 18: ...y another channel Press the Up button to highlight the channel Use the or buttons to change the channel Press the Down button and select OK Gage Name Enter a unique name for the Gage up to 14 Characte...

Страница 19: ...to specified URL for each reading The URL can contain tags which are replaced by the PosiTector with values corresponding to the reading This solution turns the PosiTector gage body into an Internet o...

Страница 20: ...om the Networks menu option Networks Searches and displays all available WiFi networks within range Select a network then enter the password if required The WiFi icon will appear on the display NOTE S...

Страница 21: ...as a simple BLE keyboard Each reading is typed followed by a carriage return enter This provides a simple way to capture readings as they are taken without any special software drivers or complex set...

Страница 22: ...hen the next reading is taken in a batch flagged for synchronization or when the Sync Batches option is selected at the bottom of the list of selected batches NOTE If Bluetooth Smart is disabled data...

Страница 23: ...hlight the desired option and press the center navigation button to select it On menus longer than one page the current page number is displayed below the menu name Navigate between pages using the Up...

Страница 24: ...minutes of inactivity and enter Sleep Mode While in Sleep Mode the gage powers up significantly faster convenient when moving between parts or locations The gage will completely power off after 4 hour...

Страница 25: ......

Отзывы: