Charging
The charger starts charging the battery with
constant current up to 14.4V (at 25°C). The
charge voltage is then held constant at 14.4V and
the charging current is reduced until it is below
a defined level. The charge voltage then drops to
13.8V, before the long-term charging phase starts.
During charging, battery charge is shown by the
number of LEDs illuminated. The blinking segment
above these LEDs indicates active charging. Once
full battery charge is reached, all 5 LED segments
remain illuminated.
If the measured battery voltage is below 2.0V,
the charger will enter Error Mode.
Post Analysis
The charger analyses the battery again after the
charging phase. If the charger detects an error in
the battery, the warning triangle will flash. Post
analysis can detect batteries with a short circuit in
individual cells. This cannot be detected in the pre
analysis. If the battery voltage drops below 12.5V
within 2min, the charger will go into error mode.
The charging sequence will be stopped.
Long-term charging
After the battery is fully charged, the charger will go
in to Sleep Mode. This is indicated by all battery
LEDs slowly pulsating. This mode has a very low
power consumption.
After a week in Sleep Mode, the charger will
wake up and begin a new charging cycle.
The charger will also wake up and start a
charging cycle if battery voltage drops below 12.6V.
Содержание 701785
Страница 1: ...10A 8A 6A SmartCharge Technical Manual 4A...
Страница 3: ...3 English 4 9 10 17 Lietuvi kai 18 23...
Страница 10: ...10 1 2 3 4 5 AGM 12 8 225 6...
Страница 11: ...11 7 8 9...
Страница 12: ...12 AGM 12 65 12 55V 12 65 12 45V 12 55 12 35V 12 45 2 0V 12 35 95 100 80 60 40 0 20 4 3 2 1...
Страница 13: ...13 14 4 25 C 14 4 13 8 2 0...
Страница 14: ...14 12 5 2 12 6...
Страница 15: ...15 25 C 0 03 C 15 3 14 7 14 7 0 3 14 7...