background image

Product Manual V2.0

COSMIQ Dive Companion

Firmware Version 0.7

Содержание COSMIQ DIVE COMPANION

Страница 1: ...Product Manual V2 0 COSMIQ Dive Companion Firmware Version 0 7 ...

Страница 2: ...ressure of Oxygen PPO2 19 5 2 5 During a Dive 19 5 2 6 Central Nervous System CNS Oxygen Toxicity 20 5 2 7 Maximum Operating Depth MOD 20 5 2 8 Ascent Rate 21 5 2 9 Safety Stop 22 5 2 10 Exceeding the No Decompression Limit 22 5 2 11 After Diving 24 5 2 12 No Dive Time and No Fly Time 24 5 3 Gauge Mode 24 5 3 1 Preparing to Dive 25 5 3 2 During the Dive 25 5 3 3 After Diving 25 5 3 4 Lockdown for ...

Страница 3: ...nd performs decompression saturation and desaturation calculations for Standard Air and Nitrox dives Deepblu Decompression Algorithm based on the calculations on the Bühlmann ZH L16C model Three Safety Factor settings Conservative Normal or Progressive Nitrox capable the oxygen level FO2 is adjustable between 21 and 40 Dive Plan function for planning dives in advance Freedive Mode built specifical...

Страница 4: ...hallenging environments such as in caves wrecks ice high altitude lakes or any sort of penetration diving using trimix or any other kind of air mix with oxygen levels lower than 21 or higher than 40 or any technical diving please DO NOT use this device as your primary recording device gauge or computer The COSMIQ Dive Companion is only designed and intended for use in recreational scuba diving and...

Страница 5: ...ne 15th 2016 0 6 Added timeout setting for OTA firmware upgrade process Optimized battery consumption and adjusted battery power indicator May 24th 2016 0 5 Added Safety Factor function allowing users to set COSMIQ s algorithm to Conservative Normal or Progressive Added option to set PPO2 level between 1 2 bar and 1 6 bar Added Err display message in Dive Plan mode when Scuba Mode is locked NDL ba...

Страница 6: ...equate or improper training may cause a diver to engage in behavior that may lead to serious injury or death 4 ONLY FREEDIVERS TRAINED AND CERTIFIED BY A RECOGNIZED AGENCY IN THE APPROPRIATE USE OF FREEDIVING TECHNIQUES SHOULD USE THE COSMIQ DIVE COMPANION Using a dive computer is not a substitute for receiving adequate and proper training Inadequate or improper training may cause a diver to engag...

Страница 7: ...e risk of oxygen toxicity and decompression illness 9 ALWAYS ENSURE THE PROPER FUNCTIONING OF COSMIQ BEFORE DIVING Before diving check the display screen to confirm that information is being displayed clearly Toggle between modes to check that it is functioning properly Additionally make sure that there is sufficient battery power to complete your dive DO NOT dive if the computer s display is not ...

Страница 8: ...FERENCE GUIDE 1 8 11 12 9 10 2 3 4 5 6 7 NDL Graphic Bar No Decompression Limit Scuba Gauge Mode Current Depth Freedive Mode Dive Time Ascent Rate Bar Water Temperature 8 11 12 9 10 Freedive Mode Log Mode Sync Mode Gauge Mode Scuba Mode Watch Mode 1 2 3 4 5 6 Battery Power Indicator 7 ...

Страница 9: ...ent Time Gauge Mode Time In Log Mode Time Watch Mode Current Depth Scuba Mode Nitrox Scuba Mode Dive Time Freedive Mode Sync Time Sync Mode No Dive Time Watch Mode Max Depth or Ceiling Depth Scuba Mode Max Depth Freedive Mode Depth Dive Plan No Fly Time Watch Mode Stop Countdown Time Scuba Mode Max Time Freedive Mode Log Number Log Mode No Decompression Limit in mins Dive Plan Ascend Descend icon ...

Страница 10: ...rent depth dive time and water temperature Freedivers can set a Max Depth and or Max Time alarm Log Mode Allows you to access all dive data from previous dives Maximum depth dive time water temperature time in date and the number of the dive are all displayed for each saved dive Sync Mode Use this mode to upload dive data from COSMIQ to the Deepblu app via Bluetooth The firmware version that your ...

Страница 11: ...ents it will beep once every minute as a reminder that you should charge COSMIQ immediately It will also beep once right before it shuts down due to lack of battery power WARNING DO NOT DIVE WITH COSMIQ IF THE BATTERY LEVEL INDICATOR IS DISPLAYING 0 SEGMENTS Doing so may cause COSMIQ to fail during a dive and may lead to serious injury or death WARNING THE ACTUAL STATUS OF THE BATTERY DEPENDS ON T...

Страница 12: ...t distance measurement units will be set to the Metric system Syncing your COSMIQ with the Deepblu mobile app is necessary for adjusting the majority of COSMIQ s settings including time and date distance measurement units underwater alarms and more Syncing with the app also necessary for creating digital dive logs and linking the product with your personal Deepblu account for registration and warr...

Страница 13: ...sfully paired the first time your phone will automatically establish a Bluetooth connection with COSMIQ when you sync them in the future For the Deepblu Android app Access the Deepblu app and press COSMIQ in the main menu When you re ready to pair press Scan Press the Sync icon in the top right hand corner Select your COSMIQ A running rectangle will appear on COSMIQ to show the devices are pairing...

Страница 14: ...ressive The default is Normal Partial Pressure of Oxygen PPO2 Change the maximum PPO2 limit from 1 2 bar to 1 6 bar The default is 1 4 bar Air Mix Choose the oxygen level based on the type of gas being used in your cylinder Standard Air or Nitrox The minimum is 21 and the maximum is 40 This setting can also be adjusted manually using COSMIQ The default is 21 Time Alarm Set an alarm to sound once y...

Страница 15: ...Use the ADJUST button repeatedly to toggle within the mode Press the MODE button to exit Please see below Section 5 for a detailed description of each mode and instructions for adjusting the settings within the various modes 4 7 NON ADJUSTABLE SETTINGS Please note that the following settings are pre programmed into COSMIQ and cannot be changed at any time Altitude The altitude level for COSMIQ is ...

Страница 16: ...curate measurements and therefore may cause you to dive beyond safe limits increasing your risk of serious injury or death WARNING DO NOT ATTEMPT MULTI GAS DIVING WITH COSMIQ COSMIQ does not have the capability to support calculations for multi gas diving and therefore should only be used for Standard Air or Nitrox dives WARNING ONLY DIVERS WHO HAVE UNDERGONE SPECIALIZED TRAINING FROM AN ACCREDITE...

Страница 17: ...nning a Dive To access the Dive Plan function press the ADJUST button one time if COSMIQ s display is in Watch Mode or two times if it is in Standby You will hear a beep and the screen will change to show the word PLAN as well as a value for depth and a value for the corresponding no decompression limit When you first enter the Dive Plan screen the minimum depth displayed is 9 meters 30 feet It is...

Страница 18: ... will automatically activate Scuba Mode once you descend past 2 meters 6 5 feet Manual activation Alternatively navigate to Scuba Mode using the MODE button Enter the water and begin descent while in Scuba Mode NOTE On the surface COSMIQ refreshes its sensors and captures data at 15 second intervals in Watch Mode Therefore there may be a slight delay between descending below 2 meters 6 5 feet and ...

Страница 19: ...ents of your cylinder and set the appropriate oxygen percentage will cause COSMIQ to calculate and display inaccurate information 5 2 3 Safety Factor The Safety Factor controls the decompression algorithm COSMIQ uses to perform decompression calculations It allows you to set the level of conservativeness based on your personal preference and unique risk factors There are three levels to choose fro...

Страница 20: ...shallower depth The alarm will become more frequent if you do not ascend to a shallower depth and the calculated CNS level increases to 85 or higher In the case of a CNS alarm you should conduct a safety stop and end the dive immediately WARNING DO NOT ALLOW YOUR CNS LEVEL TO REACH 100 Doing so greatly increases the risk of oxygen toxicity Oxygen toxicity may cause your body to suffer from convuls...

Страница 21: ...nt rate slower than 12 meters 40 feet per minute to be a safe ascent rate If the safe ascent rate is exceeded the alarm will sound and will continue to beep until you slow your ascent rate The ascent rate bar operates according to the table below Ascent Rate Ascent Speed No bars Slower than 4 meters 13 feet per minute 1 bar 4 6 meters per minute 13 20 feet per minute 2 bars 6 8 meters per minute 2...

Страница 22: ...will pause until you return to the depth range at which point it will continue the countdown where it left off 5 2 10 Exceeding the No Decompression Limit During a dive in Scuba Mode the no decompression time limit is visible in the top right hand corner of COSMIQ s display screen underneath the No Deco indicator The no decompression limit is also represented by a graphic bar on the right hand sid...

Страница 23: ...hould still conduct a regular safety stop at the end of your dive If you do not begin to ascend within 3 minutes of exceeding the NDL the decompression stop becomes mandatory The Ceiling Depth value and the Stop Countdown Time will continue to flash until you ascend to the ceiling depth and conduct a decompression stop Obey the warnings and ascend to the ceiling depth to complete a decompression s...

Страница 24: ... is represented as 0 5 and 1 hour is represented as 1 0 If your No Dive Time is longer than 30 minutes COSMIQ will display the error screen with the letters SUF and will go into lockdown after you reach the surface The letters SUF are a reminder that you should stay on the surface in order to allow for nitrogen desaturation The length of the lockdown time will depend on calculations of residual ni...

Страница 25: ...descending below 2 meters 6 5 feet and Gauge Mode activating 5 3 2 Gauge Mode During a Dive Once you descend past 2 meters 6 5 feet COSMIQ will lock into Gauge Mode The MODE and ADJUST buttons will be disabled for the duration of the dive No settings can be changed and no other modes can be accessed during the dive During a dive using Gauge Mode the following information will be displayed Current ...

Страница 26: ...ion If Freedive Mode is not your default underwater mode you must activate it manually Navigate to Freedive Mode using the MODE button Enter the water and begin descent while in Freedive Mode NOTE On the surface COSMIQ refreshes its sensors and captures data at 15 second intervals Therefore there may be a slight delay between descending below 2 meters 6 5 feet and Freedive Mode activating When you...

Страница 27: ...continuously until you ascend above that depth When you reach the dive time set on your Max Time alarm the alarm will sound for 6 cycles of 3 beeps per cycle 5 4 4 Freedive Mode Surface Interval Upon surfacing from a dive in Freedive Mode COSMIQ will begin to count the Surface Interval Time It will be displayed on the display screen in Freedive Mode and Watch Mode COSMIQ will calculate a safe Surf...

Страница 28: ...s a scuba diving Remember you are responsible for your own safety WARNING FREEDIVING AND SCUBA DIVING SHOULD NOT BE CONDUCTED ON THE SAME DAY Conducting freedives and scuba dives on the same day increases your risk of decompression illness 5 5 LOG MODE Dive data measured from previous dives is recorded and saved in Log Mode You can only access the Log Mode when you are above the surface To access ...

Страница 29: ... are close to each other Step 3 Sync Dive Data For the Deepblu iOS app Access the Deepblu app on your mobile device In the main menu of the Deepblu app press Create Log Next press the Sync icon in the top right corner of the app Dive data will be uploaded automatically Your phone will show the progress of the syncing process Maintain the connection while COSMIQ uploads your logs The process should...

Страница 30: ...0 seconds 10 second pause repeat for 3 minutes Arrow indicator flashing Stop indicator and Stop Countdown Time flashing Ceiling indicator and Ceiling Depth value flashing Perform a mandatory decompres sion stop Ascend to the Ceiling Depth indicated in the bottom left corner of COSMIQ and stay there until the Stop Countdown Time is over Do not ascend above the Ceil ing Depth until the Stop Countdow...

Страница 31: ... 2 Disposal of Device Electrical and electronic devices must not be disposed with consumer waste as they are considered hazardous Their components must be recycled or disposed separately from regular waste to prevent contaminative and hazardous substances from polluting our environment Dispose of the COSMIQ Dive Companion as electronic waste Do not throw it in the garbage with regular trash Please...

Страница 32: ... Battery Life 6 to 7 hours of continuous use Battery Charger Standard USB Log Storage Up to 25 logs unsynchronized Data Transfer Bluetooth 4 0 Dive Log Software Deepblu iOS App and Deepblu Android App Firmware Upgrade Free OTA firmware upgrades Housing Material Fibreglass reinforced polycarbonate Lens Material Polycarbonate with 8h hardness coating Screen Technology Enhanced Black Twisted Nematic ...

Страница 33: ...ador or a COSMIQ Reseller the warranty period begins at the time of purchase from the Sales Ambassador or the COSMIQ Reseller The warranty does not cover commercial or rental use nor does it extend to units purchased from anyone other than an authorized Deepblu Sales Ambassador COSMIQ Reseller or the Deepblu Webstore The warranty specifically excludes battery depletion or other conditions resultin...

Страница 34: ... of repetitive dives completed within a day or over a number of days Dive time The amount of time that elapses between the beginning of a dive and the end of a dive Maximum operating depth MOD The depth limit which the PPO2 level exceeds the maximum allowable lev el based on the limit set 1 2 bar to 1 6 bar Diving below the MOD may expose the diver to unsafe PPO2 levels Nitrox Also called Enriched...

Страница 35: ...ngerous and may be toxic Residual nitrogen The amount of excess nitrogen remaining in a diver s body after one or more dives Safety Factor The level of conservativeness of the decompression algorithm This allows the user to select a standard decompression algorithm a conservative algorithm or a progressive algorithm Stop Countdown Time The amount of time required to complete a safety stop or a man...