DIVK-C 91 INSTALLATION  TO A SUSPENDED CEILING

 

 

The ceiling-mounting plate is attached  
to the roof with M8, thread bars (not included in the 
delivery). 

                                                                                                                       RUBBER SILENCER 
                                                                                                                                      WASHER 
                                                                                                                                                       NUT 

4

5mm

40-50
mm

The head of the threaded bar can not  
reach below the bottom of the plate.  
 
The unit will be pushed to the mounting plate and  
tightened with four M8 bolts against the  mounting plate 
so that the cover seal of the unit is evenly sealed against 
the mounting plate, not tighter. 

MOUNTING PLATE BINDING                                                       
UPPER SURFACE IS  
INSTALLED 5 mm 
BELOW THE ROOF SURFACE 

 LEAVE A  40-50MM GAP  
BETWEEN THE CEILING AND 
THE  FRONT EDGE OF THE  
MOUNTING PLATE 

SERVICE HATCH

M8 THREADED BAR

 

BACKUP NUT

THE UNIT IS PULLED 
 INTO THE MOUNTING  
PLATE  “RAILS” 

WASHER

BOLT M8X40

THE UNIT IS ATTACHED 
TO THE MOUNTING  
PLATE FROM THE INSIDE  
BY FO UR M8 BOLTS 

MEASURES OF THE MOUNTING PLATE 

SERVICE HATCH

SERVICE HATCH

DOOR

FRONT EDGE

DOOR

Содержание TALTERI DIVK-C 91 C

Страница 1: ...F AIR CONDITIONING COME TRUE WITH THE RECOVERY SYSTEM TALTERI removes used air from interior and brings in fresh air Humidity and impurities are exhausted through thermal recovery unit that heats the filtered ambient air cost effectively The fresh warm air is channelled draught free and noise free into the premises in necessary quantities ENSURE THE QUALITY OF AIR EXCHANGE ...

Страница 2: ...S LEFT Adjusting voltage Kitchen exhaust air volumes Kitchen exhaust air volumes 70 80 90 100 43 49 55 60 l s 3 11 4 11 1 9 2 6 5 7 8 12 10 14 15 13 16 Pa 200 100 80 40 60 20 Airflow 40 50 60 70 80 90 100 EXTRACT AIR SUPPLY AIR 90 250 Pa 200 100 80 40 60 20 Airflow 40 50 60 70 80 90 100 90 250 External ductwork pressure 10 1V 10 1V External ductwork pressure l s l s Fan speed 40 50 60 70 80 90 100...

Страница 3: ... technical or warm storages In case the temperature of the installation location is lower than room temperature the factory settings of the appliance must be changed to obtain faultless functioning The unit can not be installed into cold outer premises or garages UPPER BASE DUCT The channelling is usually mounted to the upper base thermal insulation The steam barrier puncture must be carefully sea...

Страница 4: ... against the mounting plate so that the cover seal of the unit is evenly sealed against the mounting plate not tighter MOUNTING PLATE BINDING UPPER SURFACE IS INSTALLED 5 mm BELOW THE ROOF SURFACE LEAVE A 40 50MM GAP BETWEEN THE CEILING AND THE FRONT EDGE OF THE MOUNTING PLATE SERVICE HATCH M8 THREADED BAR BACKUP NUT THE UNIT IS PULLED INTO THE MOUNTING PLATE RAILS WASHER BOLT M8X40 THE UNIT IS AT...

Страница 5: ... KITCHEN HOOD ELECTRICAL CONNECTION BETWEEN THE KITCHEN HOOD AND THE HRV UNIT DIVK C 91 C 2x0 5 C A Coupler male Coupler female 24 0 0 10 CO2 RH1 B C A B O x contact tip information of the damper max 5A 230V Kitchen hood Ultra PG EC PC EC 5 K S K S T1 T2 T3 T4 T5 T6 OUT SUP PLY EX TRACT EX HAUST WA TER PRE HEATER POST HEATER CONTROL PANEL 230VAC L N PE FUSE TEMPERATURE SENSORS 24 0 0 10 CO2 RH1 24...

Страница 6: ...rpressure for preventing overload The unit must be used with full power and check the drainage of the condensing water The appliance filters and heat exchangers must be cleaned and the systemadjusted after the construction works are completed BASIC ADJUSTMENT OF AIRFLOW The unis alone can not produce good indoor air in case the channels and fans are installed carelessly and main adjustments are no...

Страница 7: ...ls to 5 degrees lower than the set valut The preaheater can be coupled off by setting the set value 10 oC when the supply fan is switched off 5 During very cold weather and when there is higher humidity there can be ice formation in the heat exchanger If such a case occurs setting the value clockwise obtained by raising the defrost cycle to start earlien The setpoint can reduces In the dry conditi...

Страница 8: ...s defrozen by using the preheater The power of the preheater is mainly adequate to keep the heat recovery cell defrozen In extreme conditions if the power of the preheater is not sufficient the supply fan power will be reduced or stopped by the freezing protection thermostat when the exhaust air temperature drops below the set value 0 C The supply fan starts when the exhaust air temperature rises ...

Отзывы: