4
Detection is done automatically.
6.4.2.
Setting the burner’s 3 operating outputs
CAUTION
4
The burner must only be set electronically.
4
Setting is done in the following order: maximum
output - start-up output - minimum output.
4
In order to adapt the settings to the installation
conditions, run the combustion test.
¼
See chapter: "Checking combustion", page
To set the required CO
2
levels, set the air flow rate (U) and, if
necessary, the oil pressure (P).
To set the burner parameters, proceed as follows:
1. Set the parameter
INSTALLATION
to
EXTENDED
¼
See chapter: "Displaying the parameters in extended
2. Briefly press the
-
key.
3. Turn the rotary setting button to select the maximum output
A
.
4. Confirm by pressing the rotary setting button. The arrows flash.
5. Turn the rotary setting button to change the air flow rate setting.
Confirm by pressing the rotary setting button.
6. Set the oil pressure by holding down the key (see illustration). To
change the values, proceed as for setting the air flow rates.
7. Confirm by pressing the rotary setting button.
¼
Factory setting values: See table below.
To set the output, it is necessary to limit oneself to setting
the U value (fan rotation speed). If the CO
2
value cannot
be reached, reduce the oil pressure value.
8. To exit this menu, press the
j
key.
Factory setting values
Burner model - Boiler power Output
P (bar (MPa))
(1)
U (%)
Indicative setting
(2)
CO
2
(%) Head pressure
(mbar)
Indicative setting
F10E2-5.18 - 18 kW boilers
E
Minimum output 7 (0,7)
34
10,5
5,5
Z
Start-up output
17 (1,7)
65
12,1
8,6
A
Maximum output 20 (2,0)
71
12,5
9,9
F10E2-5.24 - 24 kW boilers
E
Minimum output 7 (0,7)
41
10,5
5,3
Z
Start-up output
15 (1,5)
69
11,5
8,2
A
Maximum output 22 (2,2)
86
12,5
10,4
(1) Fuel oil pressure
(2) Fan rotation speed
0
2
4
6
8
10
12
14
16
18
22
24
20
C
0
0
3
26
4
-C
GENE
T:18.1°
P(bar)
U(%)
E
7.0
56.0
l
l
l
l
l
l
l
l
l
Z
15
73.0
A
22.0
81.0
A
Pa:17.7 bar
b
AUTO
M
C003896-C
0
2
4
6
8
10
12
14
16
18
22
24
20
GENE
T:18.1°
P(bar)
U(%)
E
7.0
56.0
l
l
l
l
l
l
l
l
l
Z
15
73.0
A
22.0
81.0
A
Pa:17.7 bar
b
AUTO
M
6. Commissioning
AFC 18 - AFC 24 - AFC 30
100
09/07/2015 - 300026439-07