C140
C140 – 45
C140 – 65
C140 – 90
Part load heating mode efficiency (92/42/EEC)
(return temperature 30 °C)
%
110.6
110.4
108.1
Part load heating mode efficiency (GB20665–
2015) (return temperature 30 °C)
%
108.0
107.8
107.9
(1) Factory setting
Tab.14 Gas and flue gas values
C140
C140 – 45
C140 – 65
C140 – 90
G20 gas consumption (H gas)
min.–max.
m
3
/h
0.9 - 4.4
1.3 - 6.6
1.5 - 9.1
Gas consumption G31 (propane)
min–max
m
3
/h
0.4 - 1.7
0.5 - 2.5
0.9 - 3.5
Gas resistance G20 (H gas)
max
mbar
1.0
2.0
2.5
NOx annual emissions G20 (H gas) O2 = 0%
mg/kWh
(HHV)
33
29
41
Flue gas quantity
min–max
m
3
/h
12 - 60
18 - 90
22 - 125
Flue gas temperature
min–max
°C
30 - 67
30 - 67
30 - 67
Maximum counter pressure (Pn)
Pa
150
100
160
(1) Gas consumption based on lower heating value in standardised conditions: T=288.15 K, p=1013.25 mbar. Gag 30.33; G25 29.25; G31
88.00 MJ/m3
(2) Gas resistance between boiler connection and measurement point on the gas valve unit
Tab.15
C140
C140 – 45
C140 – 65
C140 – 90
Gas inlet pressure G20 (H gas)
min–max
Pa
1500 - 3000
1500 - 3000
1500 - 3000
G30/G31 gas inlet pressure (Butane/Propane)
min–max
Pa
3700 - 5000
3700 - 5000
3700 - 5000
G31 gas inlet pressure (Propane)
min–max
Pa
3700 - 5000
3700 - 5000
3700 - 5000
Tab.16 Central heating circuit data
C140
C140 – 45
C140 – 65
C140 – 90
Water content
l
5.2
7.1
10.1
Water operating pressure
MPa
0.08
0.08
0.08
Water operating pressure (MOP)
MPa
0.4
0.4
0.4
Water temperature
max
°C
110
110
110
Operating temperature range
°C
7–90
7–90
7–90
Pressure drop secondary circuit (ΔT = 20 K)
mWC
1.1
1.7
1.6
Maximum permitted temperature difference
max
°C
40
40
(1) with a maximum flow temperature of 80 °C
Tab.17 Electrical data
C140
C140 – 45
C140 – 65
C140 – 90
Type of power supply (AC)
V/Hz
~220/50
Power consumption – full load
W
68
92
124
Minimum electrical output for the thermal load
status
W
17
25
24
Power consumption – standby
W
5
6
5
Electrical protection rating
IP
IPX4D
IPX4D
IPX4D
Fuses
Main
A
10
10
10
Type of protection against electrical shocks
Class I
Class I
Class I
8 Technical specifications