Menu
Function
Programmes horaires pour le chauffage
Set and configure the time programs used when in operating mode
Programmation.
Configuration de zone
Configure the settings of the zone circuit.
Tab.6
Extended menu to configure a heating circuit Configuration de zone
Menu
Function
Dérogation de température
Change the room temperature temporarily, if required.
Mode Fct Circ
Select the heating operating mode: Scheduling, Manual.
ConsAmb Circ Manuel
Set the room temperature manually to a fixed setting.
Mode vacances
Set the start and end date of your holiday and the reduced temperature for
this zone.
Zone friendly Name
Create or change the name of the heating circuit.
Icon display zone
Select the icon of the heating circuit.
The maximum heating water temperature can be set at 7-90°C.
The water temperature of the low-temperature heating system should not
be higher than 60°C.
5.5
Changing the room temperature of a zone
5.5.1
Definition of zone
Zone is the term given to the different hydraulic circuits CIRCA, CIRCB
and so on. It designates several areas of a building served by the same
circuit.
Tab.7
Example of two zones
Zone
Factory name
1
Zone 1
CIRCA
2
Zone 2
CIRCB
5.5.2
Changing the name and symbol of a zone
The zones have a factory symbol and factory name. You can change the
name and symbol of a zone.
1. Select the tile of the zone you want to change.
2. Press the button to confirm the selection.
3. Use the rotary knob to select Zone configuration
4. Press the button to confirm the selection.
5. Use the rotary knob to select Zone friendly Name
6. Press the button to confirm the selection.
A keyboard with letters, numbers and symbols is shown.
Fig.8
Two zones
AD-3001404-01
1
2
5 Settings
7745361 - v03 - 29112021
DIEMATIC Evolution - C140
15