"Installer" level - #SYSTEM menu
Parameter
Adjustment range Description
Factory setting Customer setting
INSTALLATION CLASSIC
Displays the parameters of a conventional
installation
CLASSIC
EXTENDED
Displays all parameters
Regardless of what is done to the keys, the regulator
switches back to
CLASSIC
mode after 30 minutes.
5.5.2.
Setting the parameters specific to the
installation
1. Access the "installer" level: Press key
-
for around 5 seconds.
2. Select the menu
#SYSTEM
.
4
Turn the rotary button to scroll through the menus or
modify a value.
4
Press the rotary button to access the menu selected
or confirm a value modification.
¼
For a detailed explanation of menu browsing, refer
to the chapter: "Browsing in the menus", page 62
3. Set the following parameters according to the connections made
to the PCBs:
"Installer" level - #SYSTEM menu
Parameter
Adjustment range Description
Factory setting Customer
setting
CIRC. A:
(1)(2)
DIRECT
Use as a direct heating circuit
DIRECT
PROGRAM.
Use as an independent programmable outlet
H.TEMP
Enables operation of circuit A in summer despite
manual or automatic summer shutdown
DHW
Connection of a second domestic hot water tank
DHW ELEC
Used to control the electrical resistor according to the
timer programme on circuit A in summer mode
DISAB.
No data for circuit A is displayed
CIRC. B:
(1)
3WV
Connecting a circuit with 3-way valve (For example:
Underfloor heating)
3WV
SWIM.P.
Using the circuit for pool management
DIRECT
Use of circuit in direct heating circuit
CIRC. C:
(1)
3WV
Connecting a circuit with 3-way valve (For example:
Underfloor heating)
3WV
SWIM.P.
Using the circuit for pool management
DIRECT
Use of circuit in direct heating circuit
(1) The parameter is only displayed if
INSTALLATION
parameter is set to
EXTENDED
(2) If the pump incorporated in the boiler is used for circuit A (parameter
CIRC.A
set to
DIRECT
), the
O.PUMP A
outlet is free
(3) This parameter is displayed only if the
O.PUMP A
parameter is set to
CIRC.AUX
or if the 3-way valve PCB option is used
1
1
2
2
r
c
STD
(
'
t
v
0
2
4
6
8
10
12
14
16
18
22
24
20
p
b
AUTO
x c
r
j
M
g
m
SUNDAY 11:45
5"
TEMP.: 68°
C002235-F-04
5. Start-up
MCA 15 - MCA 25 MCA 25/28 MI
72
29/04/2010 - 300022146-001-B