![DeDietrich GT 123 A Скачать руководство пользователя страница 15](http://html.mh-extra.com/html/dedietrich/gt-123-a/gt-123-a_installation-and-maintenance-manual_2462442015.webp)
15
09/02/08 - 94863361 - 85784009D
GT 120 A - GT 1200 A
Step eight
Putting the burner cable into place
Install the grommet for the burner cable (delivered in the control
panel instructions pack) in the notch provided for it at the control
panel support on the side of the burner door opposite the hinges
according to European safety standards (originally: on the left side. If
the direction of opening of the burner door has been reversed: it will
be on the right side).
- Put the burner cable in the grommet.
Fit the cable clamp on the side panel (on the side on which the
burner cable is located).
- Remove the burner cover.
Connect the connector onto the burner connector.
- Adjust the cable length so that the burner cable has to be
disconnected to open the burner door. Slide the surplus cable
backwards between the insulation and the side panel, then:
Fix the burner cable in the cable clamp using two ø 3.5 x 25
screws.
- Replace the burner cover.
Step nine
Installing the bulbs
Install the bulbs (the number varies epending on the type of the
control panel) in the thimble tube at the back of the boiler. Use the
thimble tube contact spring (delivered in the casing instructions pack)
if there are two bulbs. (The contact spring for the thimble tube is
useless if there are four bulbs).
- Hold the cables in place using the thimble tube spring
.
A
: B control panel : boiler sensor, safety ther contact spring
B
: E control panel : thermometer, boiler thermostat, boiler sensor,
safety thermostat, no contact spring