5

14/11/2005 - 300006361-001-A

DTG X .. N

Commissionning

Initial commissioning must be done by a qualified
professional.

1. Check the water pressure in the installation. Top up with more

water if necessary.

2. Open the gas valve.

3. Check that the safety thermostat has not triggered. Remove the

safety thermostat hood and press the reset button with a
screwdriver.

4. Set the On/Off switch to 1.

5. Set the Summer/Winter swtich to 

.

.

6. Create a requirement for heat: Place the boiler thermostat  in the

required position.

7. The safety box carries out its ignition cycle.

If the safety control box malfunctions, reset it by pressing the
reset button. Make a further attempt to light it.

Check that the heating pump is working (not gummed up).
Degum the pump if necessary.

Stopping the boiler

Set the On/Off switch to 0.

Precautions to take if there is a danger of frost

Heating circuit:
Use a correctly dosed antifreeze to prevent the heating water
freezing. If this cannot be done, drain the system completely. In all
cases, consult the fitter.
Domestic hot water circuit:
Drain the domestic water tank and pipes.

Precautions to take in the event of prolonged shutdown (one 

year or more)

- Close the gas valve
- The boiler and the chimney must be swept carefully. 
- Close the door of the boiler to prevent the internal circulation of air.

Troubleshooting

Checks to make before calling your fitter:
The burner is not working:
- Check the boiler thermostat settings.
- Shutdown by the safety thermostat due to accidental overheating.

Check that the safety thermostat has not triggered. To restart the
boiler, reset the safety thermostat. Remove the safety thermostat
hood and press the reset button with a screwdriver. Carry out the
start-up operations again. Call your fitter.

- The safety control box is malfunctioning. Press the reset button on

the safety control box. Call your fitter.

The burner is operating but the radiators are cold:
- Bleed the radiators.
- Top up the primary circuit with water.
- Check that the heating pump is operating correctly.
- If it is often necessary to top up the installation with water, contact

your fitter.

Before informing the fitter of a fault, make a note of the following
information:
- Product type
- Year of manufacture
- Serial number
- Type of gas used

This information can be found on the rating plate stuck to  the front
plate of the boiler.

Содержание DTG X..N

Страница 1: ...DTG X N Low temperature gas furnace English 14 11 2005 Instructions for use...

Страница 2: ...missionning 5 Stopping the boiler 5 Troubleshooting 5 Symbols used Caution danger Risk of injury and damage to equipment Attention must be paid to the warnings on safety of persons and equipment Speci...

Страница 3: ...oss section of the aeration vent which is compulsory in the premises in which the boiler is installed must comply with the DTU 61 1 P 45 204 standard and in particular with the instruction on general...

Страница 4: ...ction window 10 Ionisation probe 11 Ignition burner 1 Timed circuit breaker 4 A 2 General ON 1 OFF 0 switch 3 3 positions switch Winter Summer STB TEST 4 Boiler thermometer 5 Boiler thermostat 6 Safet...

Страница 5: ...estic water tank and pipes Precautions to take in the event of prolonged shutdown one year or more Close the gas valve The boiler and the chimney must be swept carefully Close the door of the boiler t...

Страница 6: ...facturer s instructions in particular those relating to the regular maintenance of the unit the rules of the profession The warranty is limited to the exchange or repair of such parts as have been rec...

Страница 7: ...7 14 11 2005 300006361 001 A DTG X N...

Страница 8: ...e la Gare F 67580 MERTZWILLER BP 30 www dedietrich com AD001X 09 2005 D B CH NEUBERG S A www dedietrich com DE DIETRICH HEIZTECHNIK www dedietrich com L AU F Direction des Ventes France 57 rue de la G...

Отзывы: