3.2
Technical data
3.2.1
Boiler specifications
Tab.5
General
Alezio G hybrid
24/28 MI
34/39 MI
Nominal heat output (Pn)
Central heating operation (80 °C/60 °C)
min–max
kW
5.5 - 23.8
19.8
7.7 - 34.7
29.8
Nominal heat output (Pn)
DHW operation
min–max
kW
5.5 - 27.5
27.5
7.7 - 37.8
37.8
(1) Factory setting
Tab.6
Details of gas and flue gas
Alezio G hybrid
24/28 MI
34/39 MI
Gas consumption G20 (H gas)
min–max
m
3
/h
0.59 - 2.98
0.83 - 4.13
Gas consumption G25 (L gas)
min–max
m
3
/h
0.69 - 3.47
0.96 - 4.80
Gas consumption G31 (propane)
min–max
m
3
/h
0.29 - 1.15
0.41 - 1.47
NOx annual emissions G20 (H gas)
EN297: O2 = 0%
ppm
45
56
Central heating chimney efficiency (Hi)
(80/60°C) at 20 °C amb.
%
97.2
97.0
Central heating chimney losses (Hi)
(80/60°C) at 20 °C amb.
%
2.8
3.0
Tab.7
Central heating circuit data
Alezio G hybrid
24/28 MI
34/39 MI
Water content
l
1.6
1.7
Water operating pressure (MOP)
max
bar
3.0
3.0
Water temperature
max
°C
110.0
110.0
Operating temperature
max
°C
90.0
90.0
Tab.8
Domestic hot water circuit data
Alezio G hybrid
24/28 MI
34/39 MI
Specific hot water flow rate D (60 °C)
l/min
7.5
10.5
Specific hot water flow rate D (40 °C)
l/min
13
18.3
min
l/min
1.2
1.2
Operating pressure (Pmw)
bar
8
8
(1) Minimum amount of water that comes out of the tap to make the boiler start.
Tab.9
Electrical data
Alezio G hybrid
24/28 MI
34/39 MI
Supply voltage
VAC
230
230
Power consumption – full load
max
W
90
78
127
106
(1) Factory setting
3 Technical specifications
7611444 - v06 - 04032019
17