10 Appendix
10.1 Product fiche
Tab.27 Product fiche for heat pump space heaters
AWHP 4.5 MR AWHP 6 MR-3 AWHP 8 MR-2
Space heating energy efficiency class under average climate
conditions
A
++
A
++
A
++
Rated heat output under average climate conditions
(Prated or
Psup)
kW
4
4
6
Seasonal space heating energy efficiency under average cli
mate conditions
%
134
138
129
Annual energy consumption
kWh
2353
2124
3499
Sound power level L
WA
dB (A)
53
48
53
Rated heat output, under colder - warmer climate conditions
kW
5 – 4
4 - 5
6 - 6
Seasonal space heating energy efficiency, under colder - warm
er climate conditions
%
109 – 179
116 - 172
119 - 169
Annual energy consumption colder - warmer
kWh
4483 – 1249
3721 - 1492
4621 - 1904
Sound power level L
WA
outdoors
dB (A)
61
65
67
(1) If applicable
Tab.28 Product fiche for heat pump space heaters
AWHP 11 MR-2
AWHP 11 TR-2
AWHP 16 MR-2
AWHP 16 TR-2
Space heating energy efficiency class under average climate conditions
A
++
A
+
Rated heat output under average climate conditions
(Prated or Psup)
kW
6
9
Seasonal space heating energy efficiency under average climate condi
tions
%
125
121
Annual energy consumption
kWh
3999
5861
Sound power level L
WA
indoors
dB (A)
53
53
Rated heat output, under colder - warmer climate conditions
kW
4 - 8
7 - 13
Seasonal space heating energy efficiency, under colder - warmer climate
conditions
%
113 - 167
113 - 161
Annual energy consumption colder - warmer
kWh
3804 - 2580
5684 - 4120
Sound power level L
WA
outdoors
dB (A)
69
69
(1) If applicable.
See
For specific precautions about assembling, installing and
maintaining: See Safety
For more information, see
Compatible heating devices, page 11
10.2 Product fiche - Temperature Controls
Tab.29 Product fiche for the Temperature controls
E-pilot
Class
II
Contribution to space heating energy efficiency
%
2
10 Appendix
38
AWHP MIV-S
7748711 - v03 - 08062020
Содержание ALEZIO S