background image

2. Consult the information linked to the maintenance and servicing of 

your appliance:

Information

Description

Maintenance required

Indicates the necessity of mainte­

nance: yes/no

Current maintenance

Type of maintenance to come

Service run hours

Number of hours that the 

appliance has been producing 

energy since last service

Hours since service

Number of hours since the 

previous servicing of the 

appliance

Starts since service

Number of heat generator starts 

since the previous servicing.

5.5 

Check the hydraulic pressure

Regularly check the hydraulic pressure in the installation. It should be 

between 1.5 and 2 bar.

1. Select the   Water Pressure icon. 

2. Check the pressure that is displayed in the right section of the main 

screen.

3. If the pressure is less than 1.5 bar, contact the installer so that they 

check the condition of the expansion vessel, check hydraulic leak-

tightness and top up the water.

5.6 

Cleaning the casing

1. Clean the outside of the appliance using a damp cloth and a mild 

detergent.

Off

5  Maintenance

7685690 - v04 - 06042020

AWHP MIV-S

27

Содержание ALEZIO S AWHP 11 MR-2

Страница 1: ...MW 1001238 1 MW 1001238 1 en User Guide Reversible air water Split Inverter heat pump ALEZIO S MIV S 4 8 EM MIV S 4 8 EMI MIV S 4 8 H MIV S 4 8 HI MIV S 11 16 H MIV S 11 16 HI MIV S 11 16 EM MIV S 11...

Страница 2: ...sing the product and keep it in a safe place for later reference In order to ensure continued safe and efficient operation we recommend that the product is serviced regularly Our service and customer...

Страница 3: ...own the heat pump 19 4 3 Switching the central heating on off 19 4 4 Periods of absence or going on holiday 19 4 5 Regional and ergonomic parameters 20 4 6 Personalising the zones 20 4 6 1 Definition...

Страница 4: ...rocedure 30 7 2 Disposal and recycling 30 8 Energy savings 31 9 Product fiche and package fiche 32 9 1 Product fiche 32 9 2 Product fiche Temperature Controls 32 9 3 Package fiche 33 9 4 Package fiche...

Страница 5: ...e factory carry out the wiring according to the wiring diagram described in the chapter Electrical Connections See the Instal lation and Service Manual This appliance must be connected to the protecti...

Страница 6: ...Use copper pipes deoxidised with phosphorus to carry the refrigerant fluid Store the refrigerant connection pipes away from dust and humidity risk of damage to the compressor Do not use a load cylinde...

Страница 7: ...the heating circuit install a differential valve between the indoor unit and the heating circuit Fit drainage valves between the indoor unit and the heating circuit Do not add any chemical products to...

Страница 8: ...can reach temperatures in excess of 100 C and high pressures which may cause serious injuries Locate and correct the cause of power cut before resetting the safety thermostat Only genuine spare parts...

Страница 9: ...ure to abide by the instructions on installing the appliance Failure to abide by the instructions on using the appliance Faulty or insufficient maintenance of the appliance Installer s liability The i...

Страница 10: ...commissioning the appliance carefully read the instruction manuals provided 4 Dispose of used products through an appropriate recovery and recycling structure 5 Caution danger of electric shock live p...

Страница 11: ...ts In addition to the legal requirements and guidelines the supplementary guidelines in this manual must also be followed Supplements or subsequent regulations and guidelines that are valid at the tim...

Страница 12: ...1 16 ET MIV S 11 16 ETI MIV S 11 16 H MIV S 11 16 HI AWHP 16 TR 2 MIV S 11 16 EM MIV S 11 16 EMI MIV S 11 16 ET MIV S 11 16 ETI MIV S 11 16 H MIV S 11 16 HI 3 3 2 Heat pump The specifications are vali...

Страница 13: ...MR 3 AWHP 8 MR 2 AWHP 11 MR 2 AWHP 11 TR 2 AWHP 16 MR 2 AWHP 16 TR 2 Heat output kW 3 47 3 74 6 8 10 19 10 19 12 90 12 90 Coefficient of Per formance COP 3 97 3 37 3 3 3 20 3 20 3 27 3 27 Absorbed el...

Страница 14: ...16 MR 2 AWHP 16 TR 2 Weight empty kg 54 42 75 118 130 118 130 3 3 4 Combination heaters with medium temperature heat pump Tab 11 Technical parameters for heat pump combination heaters parameters decl...

Страница 15: ...Sound power level indoors outdoors LWA dB 53 61 48 65 Annual energy consumption under average conditions QHE kWh 2353 2124 Annual energy consumption under colder con ditions QHE kWh 4483 3721 Annual...

Страница 16: ...t an indoor tempera ture of 20 C and outdoor temperature Tj Tj 7 C COPd 1 95 1 87 1 85 Tj 2 C COPd 3 22 3 17 3 02 Tj 7 C COPd 4 57 4 54 4 34 Tj 12 C COPd 6 55 6 19 5 75 Tj bivalent temperature COPd 1...

Страница 17: ...d is equal to the design load for heating Pdesignh and the rated heat output of a supplementary heater Psup is equal to the supplementary capacity for heating sup Tj 2 If Cdh is not determined by meas...

Страница 18: ...formation on the selected icon 3 error notification only visible if an error occurs 4 Navigation level User level Installer level This level is reserved for installers and is protected by an access co...

Страница 19: ...ting mode is used in order to benefit from the heat pump anti blocking function and to protect the installation from frost To shut down the heat pump 1 Switch off the outdoor unit and the indoor modul...

Страница 20: ...unday in March and October Installer Details Display the installer details Cost calculation Enter the tariffs for the energy used Set Heating Activity Names Modify the name of activities used to progr...

Страница 21: ...ay Morning Evening and Custom If you desire you can personalise the name of the activities for all of the zones in your installation 1 Press the key 2 Select System Settings 3 Select Set Heating Activ...

Страница 22: ...or to change the timer programme select Scheduling 3 Select the timer programme to be activated Information on the active timer programme is given in the upper part of the screen 4 To modify the timer...

Страница 23: ...4 9 1 Selecting the operating mode For the production of domestic hot water you can choose between five operating modes We recommend the Scheduling mode which enables domestic hot water production per...

Страница 24: ...you can force domestic hot water protection to the comfort temperature DHW comfort setpoint parameter for a defined duration 1 Select the DHW tank icon 2 Select Hot water boost 3 Define the duration...

Страница 25: ...Tab 20 Parameter Description Cool Energy consumed Energy consumed for cooling DHW energy consumed Energy consumed for domestic hot water CH Energy Consumed Energy consumed for central heating 2 To re...

Страница 26: ...not drain the installation except in cases of absolute necessity E g several months absence with the risk of temperatures in the building falling below freezing 5 2 Standard inspection and maintenance...

Страница 27: ...Number of heat generator starts since the previous servicing 5 5 Check the hydraulic pressure Regularly check the hydraulic pressure in the installation It should be between 1 5 and 2 bar 1 Select th...

Страница 28: ...the value of the room temperature set point or if a room ther mostat is connected increase the temperature on it The heating mode is deac tivated Activate the heating mode The radiator valves are clo...

Страница 29: ...cycling in do mestic hot water mode The temperature set point is too low Increase the set point The water pressure is too low 1 bar Not enough water in the installation Top up the system with water W...

Страница 30: ...permanently 1 Contact the installer 7 2 Disposal and recycling Warning Removal and disposal of the heat pump must be carried out by a qualified professional in accordance with prevailing local and na...

Страница 31: ...e radiators to prevent heat losses Insulate the pipes in rooms that are not heated cellars and lofts Close the radiators in rooms not in use Do not run hot or cold water pointlessly Install an energy...

Страница 32: ...HP 11 MR 2 AWHP 11 TR 2 AWHP 16 MR 2 AWHP 16 TR 2 Space heating energy efficiency class under average climate conditions A A Rated heat output under average climate conditions Prated or Psup kW 6 9 Se...

Страница 33: ...Seasonal space heating energy efficiency class of package under average climate Seasonal space heating energy efficiency of package under average climate Tank rating Collector efficiency in Tank volum...

Страница 34: ...1 2 II package without hot water storage tank II package with hot water storage tank 0 1 00 1 00 0 1 0 70 0 63 0 2 0 45 0 30 0 3 0 25 0 15 0 4 0 15 0 06 0 5 0 05 0 02 0 6 0 02 0 0 7 0 0 1 The intermed...

Страница 35: ...iency of package under average climate Auxiliary electricity Solar contribution Water heating energy efficiency of combination heater from fiche of solar device Colder Warmer Water heating energy effi...

Страница 36: ...set tempera ture Name and temperature defined by the customer Activity 1 Sleep 16 C Activity 2 Home 20 C Activity 3 Away 6 C Activity 4 Morning 21 C Activity 5 Evening 22 C Activity 6 Custom 20 C Tab...

Страница 37: ...10 Appendix 7685690 v04 06042020 AWHP MIV S 37...

Страница 38: ...10 Appendix 38 AWHP MIV S 7685690 v04 06042020...

Страница 39: ...hnological information contained in these technical instructions as well as any drawings and technical descriptions supplied remain our property and shall not be multiplied without our prior consent i...

Страница 40: ...46 801 080 881 Infocentrala NEUBERG S A LU DE DIETRICH SERVICE AT DE DIETRICH CN www neuberg lu www dedietrich heating com www dedietrich heiztechnik com 352 0 2 401 401 0800 201608 freecall 39 rue Ja...

Отзывы: