ADVANCE
S U S T A I N A B L E C O M F O R T ®
MW
-4
0
2
1
8
-1
en
Installation, User and Service Manual
VM Diematic Evolution
AD315
Страница 1: ...ADVANCE SUSTAINABLE COMFORT MW 4000218 1 en Installation User and Service Manual VM Diematic Evolution AD315...
Страница 2: ...ng diagrams and configuration 16 6 1 Factory settings for circuits 16 6 2 Addition of 2 heating circuits 1 DHW circuit 1 swimming pool circuit controlled by VM Diematic Evolution 16 6 2 1 Electrical c...
Страница 3: ...ng curve 36 8 8 Saving the installer details 36 8 9 Saving the commissioning settings 36 8 10 Cascade operation 37 8 10 1 Managing a traditional cascade 37 8 10 2 Managing a parallel cascade 38 9 Menu...
Страница 4: ...f the appliance 2 Open the windows 3 Locate the probable source of the flue gas leak and fix it immediately 1 2 Recommendations Important Keep this document close to the place where the appliance is i...
Страница 5: ...staller must observe the following instructions Read and follow the instructions given in the manuals provided with the appliance Install the appliance in compliance with prevailing legislation and st...
Страница 6: ...r personal injury Caution Risk of material damage Important Please note important information See Reference to other manuals or pages in this manual 2 1 2 Symbols used on the appliance 1 Alternating c...
Страница 7: ...national regulations 3 1 2 Regulations and standards Beside the general technical rules the relevant standards regulations ordinances and guidelines should be followed IEC EN 60335 1 EnEV Energy Savi...
Страница 8: ...3 3 Dimensions Fig 2 642 281 325 168 12 5 281 240 230 28 28 28 28 28 28 20 45 45 45 45 22 5 45 45 45 84 84 140 5 140 5 37 281 75 5 MW 1001097 1 3 Technical specifications 8 7703592 v02 14062018...
Страница 9: ...5 WH BR YW GY GN X2 CB05 BL BR BL BR ZG1 ZG1a 3 4 1 2 A X16 X2 X5 1 3 2 X12 EEC01 GN YW 2 1 3 C X2 EEC01 1 2 3 4 5 X5 EEC01 1 2 3 4 5 X4 CB05 1 2 3 4 5 6 1 2 3 4 5 6 X4 EEC01 X16 EEC01 1 2 3 4 5 6 1 2...
Страница 10: ...patible with Diematic control systems but only if connected in slave mode 4 2 Main components 1 Door 2 Access cover to the connection terminal block 3 Diematic Evolution control panel 4 Technical serv...
Страница 11: ...water tank pump 18 Connectors for S BUS cables to CB 05 PCB 19 L BUS connection END connector 20 L BUS connection to the Diematic Evolution control panel 21 S BUS connector to connector on the fascia...
Страница 12: ...x 1 Electrical power supply 2 S BUS connection to the EEC 01 PCB 3 S BUS connection to other boxes or generators 4 4 Standard delivery The delivery includes the housing the connectors the cable glands...
Страница 13: ...ay valve AD249 Domestic hot water sensor and TAS AD212 Flow sensor after valve AD199 Sensor for buffer tank or cascade flow AD250 Outdoor temperature sensor FM46 Programmable room thermostat AD137 Wir...
Страница 14: ...e space the box requires as well as any legal requirements Install the box on a solid and stable structure Caution The box must be installed in a frost free environment 5 3 1 Data plate The data plate...
Страница 15: ...ow access and facilitate maintenance The minimum recommended dimensions are shown in the illustration in mm As standard the control panel access door opens to the left If the door s opening direction...
Страница 16: ...IRCC optional AUX optional Circuit with mixing valve Gradient 0 7 Maximum temperature 50 C DHW Domestic hot water circuit Set point temperature 55 C 6 2 Addition of 2 heating circuits 1 DHW circuit 1...
Страница 17: ...temperature sensor 24 Domestic hot water tank exchanger primary inlet 25 Domestic hot water tank exchanger primary outlet 26 DHW booster pump 27 Non return valve 28 Domestic cold water inlet 29 Pressu...
Страница 18: ...y regulated electronic pump for direct heating circuit 16 Outdoor temperature sensor 17 Sensor for buffer tank or cascade flow 99 Bridging 2 Make the S BUS connection to the generator 6 2 2 System con...
Страница 19: ...neral configuration of the sensor input 1 EP036 DHW tank top DHW Functionality of the zone CP022 DHW Layered Swimming pool CIRCC Parameters counters signals Parameters Functionality of the zone CP023...
Страница 20: ...re sensor 23 Flow temperature sensor 24 Domestic hot water tank exchanger primary inlet 25 Domestic hot water tank exchanger primary outlet 26 DHW booster pump 27 Non return valve 28 Domestic cold wat...
Страница 21: ...derfloor heating 15 Flow temperature sensor after mixing valve 16 Pump for heating circuit with mixing valve 17 Three way mixing valve 99 Bridging 2 Make the S BUS connection to the three generators 6...
Страница 22: ...v Parameters Sets the general configuration of the sensor input 1 EP036 DHW tank top DHW Functionality of the zone CP022 DHW Layered 6 4 Cascade of 2 generators addition of 3 heating circuits 1 DHW ci...
Страница 23: ...ting circuit with mixing valve 11d Swimming pool primary circuit pump 21 Outside temperature sensor 23 Flow temperature sensor 24 Domestic hot water tank exchanger primary inlet 25 Domestic hot water...
Страница 24: ...mixing valve 11 Pump for heating circuit with mixing valve 12 Three way mixing valve 13 Room Unit programmable room thermostat 14 Safety thermostat with manual reset for underfloor heating 15 Flow tem...
Страница 25: ...8 Configure the parameters for the following components Tab 16 Component Access Parameter Code Adjustment required Recirculating pump AUX Functionality of the zone CP024 Time Program Stratified tank A...
Страница 26: ...and the support 2 To remove them push towards the back of the box 3 Reverse the support and the door 4 Clip both elements back into place 7 2 Accessing the connection terminal block 1 Remove the lowe...
Страница 27: ...follows 1 Connect the cable to one of the sockets on the lower part of the box For lengths greater than 20 metres use a straight RJ12 type cable The length of the bus cable must not exceed 100 metres...
Страница 28: ...sion box In this case the VM Diematic Evolution box is connected in a network with one or more generators equipped with a Inicontrol 2 and Diematic Evolution control panel with the option of S Bus net...
Страница 29: ...p The screen goes into standby if no key is pressed for five minutes Press one of the buttons on the control panel to exit standby 1 Symbols The selected icon is highlighted 2 Information on the selec...
Страница 30: ...2 Select System Settings 3 Carry out one of the following operations Tab 20 Menu Description Set Date and Time Setting the date and time Select Country and Language Select the country and language Da...
Страница 31: ...stom 7 6 5 Personalising the name and symbol for a zone It is possible to personalise the name and symbol for a zone 1 Select the icon for the zone to be modified for example 2 Select Zone configurati...
Страница 32: ...t the Installer level select the On icon then Confirm If no actions are taken for 30 minutes the system will automatically exit the Installer level 8 3 Room temperature for a zone 8 3 1 Selecting the...
Страница 33: ...Heating Schedule 3 Select the programme to be modified The programmed activities for Sunday are displayed The last activity of the day remains active until the first activity of the following day 4 S...
Страница 34: ...dify the Comfort domestic hot water and Reduced domestic hot water set point temperatures 1 Select the icon for the DHW zone 2 Select one of the following menus Menu Description Comfort ZoneDHWtemp On...
Страница 35: ...rder to save energy To activate holiday mode for all zones including the domestic hot water 1 Select the Holiday Mode icon 2 Set the following parameters Tab 25 Parameter Description Start date holida...
Страница 36: ...ult value 15 C au tomatic mode If Base 15 C the curve base point temperature be comes equal to the room set point temperature 50 C 0 C Water temperature in the circuit for an outdoor tempera ture This...
Страница 37: ...b 28 Output type cascade algorithm Output The PI controller will calculate the output set point depending on the difference between the measured cascade temperature and the maximum temperature setpoin...
Страница 38: ...hen system temperature is 3 C above the set point temperature 3 After the duration defined by the NP009 parameter here 4 minutes the second generator shuts down if T 6 C and the system temperature is...
Страница 39: ...eed Drying Zone friendly Name Icon display zone Parameters counters signals see Tab 36 page 41 Zone Tflow setpoint ZoneTRoomUnit setp Zone RoomTemperature ZoneCurrent activity ZoneCurrentHeatMode Zone...
Страница 40: ...anced parameters and advanced signals see Tab 42 page 43 Digital Input Parameters and signals see Tab 43 page 43 Producer Manager Alg S Bus master Parameters counters signals see Tab 44 page 43 Status...
Страница 41: ...Reduced Zone Heating Curve ZoneRoomUnitInfl OperatingZoneMode ZoneStartTimeHolida y ZoneEndTime Holiday ZoneEnd Change Mode TypeReducedNightM ode Zone screed drying ScreedStartTemp ScreedStopTemp Tflo...
Страница 42: ...HW Cal Offset zone Zone IncTFlowStp DHW Zone DHW TAS enable Zone Tflow DHW temp ZonePumpSpeed Zone Tflow setpoint ZoneCurrentMode ZoneCurrent activity Zone pump run hours Zone Nbr pump starts Zone Pow...
Страница 43: ...Parameters Adv Signals Sensor in config SCB 1 Sensor in config SCB 2 Sensor input config 1 Sensor input config 2 Input meas sensor 1 Input meas sensor 2 Av input meas sensor 1 Av input meas sensor 2 T...
Страница 44: ...e Complete version Manufacturer code Hardware version Software version OBD version Global OBD version Year of manufacture Week of manufacture Day of manufacture Serial number Custom serial number Refe...
Страница 45: ...allation To revert to the commissioning settings 1 Press the key 2 Select Advanced Service Menu Revert commissioning settings 3 Select Confirm to revert to the commissioning settings 10 2 3 Reverting...
Страница 46: ...st of error codes Tab 47 Lockout codes Code Description H02 02 Waiting For Configuration Number H02 03 Configuration Error H02 04 Parameter Error H02 05 CSU does not match CU type H02 36 Functional de...
Страница 47: ...od is stated in our price list As a manufacturer we can by no means be held liable if the appliance is used incorrectly is poorly maintained or not maintained at all or is not installed correctly it i...
Страница 48: ...ts established in European Directive 99 44 EEC implemented by legal decree No 24 of 2 February 2002 and published in Official Journal No 57 of 8 March 2002 remain in force 12 Warranty 48 7703592 v02 1...
Страница 49: ...ust state the part number of the required part 13 2 Spare parts 13 2 1 VM Diematic Evolution box Fig 34 18 17 14 12 4 7 10 8 11 13 16 9 5 3 3 3 15 6 1 2 19 MW 1001111 1 Tab 49 Markers Reference Descri...
Страница 50: ...0 7672069 VM box 11 7676108 VM power cable 12 7676161 END connector 13 7676221 Cable RJ11 0 3 m 14 7618888 Traction arrester device 15 7610590 EJOT WN 5451 25X15 screw 16 7682206 Control panel cable h...
Страница 51: ...hnological information contained in these technical instructions as well as any drawings and technical descriptions supplied remain our property and shall not be multiplied without our prior consent i...
Страница 52: ...s C Salvador Espriu 11 08908 L HOSPITALET de LLOBREGAT BDR THERMEA Czech Republic s r o CZ DE DIETRICH Technika Grzewcza sp z o o PL www dedietrich cz www facebook com DeDietrichPL www dedietrich pl 4...