If it still does not work as you have followed the solutions listed above, 

do not disassemble the machine. Please consult the manufacturer for 

assistance.

Cleaning water tank

 

To keep the water tank clean, the water used should be pure water, 

distilled water or cold boiled water. we suggest to change water every day. 

The water tank should be cleaned every week. First use mild detergent 

and shake the tank to wash. Then use clean water to rinse it, 

After cleaned the water tank, please remember to put water tank plastic 

plug back to avoid leakage of oxygen from the water inlet, caused no 

oxygen output from oxygen outlet mouth when the machine is in normal 

working. 

Air filter cleaning and replacement 

The white air filter at the back of the machine can reduce noise, isolate 

dust and purify the air. It should be cleaned around every ten days. First 

use mild detergent to wash, and then rinse it with clean water. Pay special 

attention that it must be dry to be positioned back, or the function of the 

molecular sieve could be damaged, which will lead to decreased oxygen 

concentration. 

Cleaning oxygen Inhaler and atomizing components 

Oxygen inhaler should be cleaned after use, and the nasal suction head 

on the nasal inhaler should be cleaned and disinfected after use.

Soaking the inhaler in the solution of 5% potassium ferric acid for 5 

minutes, cleaning with water, or wiped with alcohol. Oxygen tube as 

consumable should be replaced regularly.

Fuse Replacement

After confirmed the power cord plug is out of power suppler outlet,using a 

slotted screwdriver to pry off the fuse holder cap, take out the defective 

glass fuse tube ,replace new one, put the cap back and tighten it. 

NO.

6

Phenomenon

Cause analysis

Solution

After startup, the
in dicator light works, 
but the machine does 
not(the sound is 
irregular).

Compressor malfunction.

The temperature is so high 
that the self protection mode 
of the oilfree compressor is 
activated.

Separation valve mulfunction

The inner conection tube of 
the machine is disconnected 
or broken.

Disconnect the power cord and 
contact professionals to repair 
it.

lt is a normal case.When the 
temperature lowers down, the 
machine will restart automati-
cally.
Disconnect the power cord and 
contact professionals to repair 
it.

Disconnect the power cord and 
contact professionals to repair 
it.

Содержание DE-1LW

Страница 1: ...USER MANAUL In order to use this product safely please read the user manual before use HOME OXYGEN CONCENTRATOR Model No DE 1LW...

Страница 2: ...01 CONTENTS Safety Precautions Product Features Key Technical Indexes Operating Instructions Cleaning Care and Maintenance Troubleshooting Working Principle 02 03 04 05 10 13 15...

Страница 3: ...ect sunlight The distance between the machine and the wall or other objects should be no less than 10cm Do not put other things or liquid vessel on the machine Stacking sundries is prohibited on the b...

Страница 4: ...ackaging so as to generate high purity oxygen by PSA at normal temperate and supply oxygen Function Feature Intelligent Control LED display timing function easy to use and simple to operate Overheatin...

Страница 5: ...ribed method PH Pass the test according to the prescribed method Morphological Identification Colorless gas odorless and tasteless combustion support Operating Noise 45dB A Dimension 340 x 180 x310mm...

Страница 6: ...e manual Please contact with the distributor or manufacture soon as if any defective Operating Instructions Appearance schematic diagram Led Display Oxygen Outlet Nebulizer Outlet Knob Humidifier Wate...

Страница 7: ...r Tank Open silica gel plug at top and fill pure water to the highest water level line Cool boiled water distilled water and so on Do not exceed water level line Make sure to cover the rubber plug bef...

Страница 8: ...point it at the nostril If using the inhaler nasal just align the two outlets with the nostril and tighten the rubber ring 1 Before using the atomization function please knob the nuts of atomiza tion...

Страница 9: ...ization the liquid is injected into the human respiratory tract through the atomization device 5 After do atomization for approximately 30 35 minutes then finished atomization press the oxygen key to...

Страница 10: ...tandby The value of the flow file will retain the setting of the flow file when the device is turned off Timing Plus timing minus key Press timing key to increase the timing each 15 minutes by one way...

Страница 11: ...ion If cooling fan fails during use the display will show a red fan icon accom panied by a buzzer alarm and the machine will stop working Automatic fault detection function For other function please r...

Страница 12: ...leaned around every ten days First use mild detergent to wash and then rinse it with clean water Pay special attention that it must be dry to be positioned back or the function of the molecular sieve...

Страница 13: ...uency of use please do these Take out humidified water tank pour water out and put it back in place Cut off power supply collect power cord Keep oxygen concentrator storage in a normal temperature and...

Страница 14: ...n discharging which is normal and is asign of fine working The flowmeter is off or the value istoo small The oxygen tube is twisted or blocked The inner connection tube of the machine is disconnected...

Страница 15: ...r malfunction The temperature is so high that the self protection mode of the oilfree compressor is activated Separation valve mulfunction The inner conection tube of the machine is disconnected or br...

Страница 16: ...e molecular sieve tower into the fine sieve tower In contrast the nitrogen is absorbed by the molecular then to be discharged into the atmosphere through the sepa rating valve The oxygen concentration...

Страница 17: ......

Отзывы: