OPERATION MANUAL                           MODEL :   CSP3  -  CLASSIC STEREO PREAMP

 

          REV 1  MAR 2018

          

IMPORTANT SAFETY 

INSTRUCTIONS! 

PLEASE READ THESE BEFORE 

OPERATING THIS EQUIPMENT. 

1.

Read and Follow these instructions. 

2.

Do not plug your preamplifier in or 

attempt to turn it on until you have 

read and followed the steps in this 

complete manual. 

3.

Never leave this preamplifier 

powered ON while unattended or at 

night when sleeping. 

  

4.

Do not use this preamplifier near 

water or in damp locations. 

5.

Do not place this preamplifier near 

any heat sources such as radiators, 

heat registers, stoves, or directly 

above other amplifiers that produce 

heat. 

6.

Do not defeat the safety of the 

three-prong power cord by 

attempting to lift the ground.  If 

you only have two-prong outlets in 

your home, have a licensed 

electrician install a grounded outlet 

near the preamplifier. 

7.

Protect the removable power cord 

from being walked on or pinched at 

either end.  

8.

Do not attempt to move this 

preamplifier until after it has been 

turned off and cooled down to 

room temperature. 

9.

Unplug the preamplifier during 

lightning storms or when unused 

for long periods of time. 

10.

Refer all service to Decware or a 

Decware authorized service tech. 

Do not attempt to fix internal 

problems. There are no user 

serviceable parts inside.   

11.

WARNING

 HIGH VOLTAGES 

PRESENT - This preamplifier stores 

up to 500 volts in the capacitors. 

Do not open the amplifier under 

any conditions. 

12.

Never touch a vacuum tube while it 

is operating.  Some can reach 

temperatures near 400 degrees F. 

13.

ALWAYS place preamplifier on a 

solid sturdy clean and level surface 

that can support its weight.

PAGE   OF 

 

 

WWW.DECWARE.COM

2

14                                                                                                                          

2

lightning flash with arrowhead, within

an equilateral triangle, is intended to

alert the user to the presence of unin-

stalled “dangerous voltage” within the

product’s enclosure that may be of risk

of electric shock to persons.

The exclamation point within an

equilateral triangle is intended to

alert the user to the presence of

important operating and mainte-

nance (servicing) instructions in the

literature accompanying the appli-

ance.

AVIS 

RISQUÉ DE CHOC ELECTRIC-NE PASOUVRIR.

WARNING- TO REDUCE RISK

OF FIRE OR ELECTRICAL

SHOCK, DO NOT EXPOSE THIS

EQUIPMENT TO RAIN OR

MOISTURE.

NO USER-SERVICEABLE PARTS

INSIDE.  REFER SERVICING TO

QUALIFIED PERSONNEL.

To prevent the risk of electrical shock, do not remove

cover or bottom.  No user serviceable parts inside.

IMPORTANT SAFETY

INSTRUCTIONS!

PLEASE READ THEM BEFORE

OPERATING THIS EQUIPMENT.

1  Read these instructions.

2  Keep these instructions.

3  Heed all warnings.

4  Follow all instructions.

5  Do not use this apparatus near water.

6  Clean only with a dry cloth.

7  Do not set things on top of apparatus.

8  Install in accordance with manufactur-

ers instructions.

9  Do not install near any heat sources

such as radiators, heat registers,

stoves, or other apparatus (including

amplifiers) that produce heat.

10  Do not defeat the safety purpose of the

polarized or grounding-type plug. A po-

larized plug has to blades with one

wider then the other. A grounding type

plug has to blades and a third ground-

ing prong.  The wide blade or the third

grounding prong are provided for your

safety.  If the provided plug does not

fit into your outlet, consult an electri-

cian for replacement of the obsolete

outlet.

11  Protect the power cord from being walked

on or pinched particularly at plugs, conve-

nience receptacles, and the point where

they exit from the apparatus.

12  Only use attachments/accessories specified

by the manufacturer.

13  Do not attempt to move this apparatus until

after it has been turned of and cooled down

to room temperature.

14  Unplug this apparatus during lighting storms

or when unused for long periods of time.

15  Refer all servicing ot  qualified service per-

sonnel.  Servicing is required when the ap-

paratus has been damaged in any way, such

as power-supply cord or plug is damaged,

liquid has been spilled or objects have fallen

into the apparatus, the apparatus has been

exposed to rain or moisture, does not oper-

ate normally, or has been dropped.

16  Do not expose this equipment to dripping or

splashing and ensure that no objects filled

with liquid, such as vases, are placed on or

near the equipment.

17  To completely disconnect this equipment

from the A.C. mains, disconnect the power

supply cord from the A.C. receptacle.

18  The mains plug of the power supply cord

shall remain readily operable.

19  Never touch a vacuum tube while it is oper-

ating.  Some can reach temperatures of al-

most 400 degrees F.

20  Turn apparatus off when not in use.

Содержание CSP3

Страница 1: ...OPERATION MANUAL MODEL CSP3 CLASSIC STEREO PREAMP REV 1 MAR 2018 PAGE OF WWW DECWARE COM 1 14 Reference Vacuum Tube Preamplifier CSP3...

Страница 2: ...SHOCK DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE NO USER SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED PERSONNEL To prevent the risk of electrical shock do not remove cover or bottom No...

Страница 3: ...calling us directly or you by e mail If you have any issues check the web site s contact page for up to date e mail addresses and phone hours We also have a strong online support forum that is very a...

Страница 4: ...have taken delivery of your preamp during cold weather please allow it to come to room temperature before you plug it in and try to use it You will need three pairs of high quality interconnects and...

Страница 5: ...4 POWER CORD 3A FUSE POWER SWITCH RIGHT OUTPUT MONO OUTPUT LEFT OUTPUT RIGHT INPUT B RIGHT INPUT A LEFT INPUT A LEFT INPUT B RIGHT OUTPUT LEVEL ADJUSTMENT 5Y3GT 5U4G 5AR4 6N1P 6922 6N1P 6922 6N1P 6922...

Страница 6: ...ved and installed Tube pins are equally important and should be cleaned every time a tube is installed Once again this will keep the tube sockets clean which is critical for maintaining top fidelity T...

Страница 7: ...SP3 contains a silver input selector switch and the switch box shown above is also using silver switching and silver Teflon internal wiring This component is called the ZSB and available on the Decwar...

Страница 8: ...annels can be individually adjusted however it is nice to have the left and right rear 9 pin tubes matched when possible so that you do not have to correct for channel imbalances that might otherwise...

Страница 9: ...d 9 pin tubes are used the tube life will be whatever the advertised lifespan is on the tube data sheet In most cases this will be around 6000 hours for a new tube Rectifier tubes are the first line o...

Страница 10: ...yet If you didn t hear any hum or noise increase when you connected your first source that means that A your cables are probably good and B there is no ground loop between the components No add your s...

Страница 11: ...loud too fast you can turn down the input level controls The CSP3 can be built with either a pair of 1 4 inch headphone jacks or a pair of 4 pin XLR jacks or one of each Also it can be built with dua...

Страница 12: ...le to adjust the gain structure with these output level controls to effect the voicing you can also do a great deal of voicing with tubes Voicing The CSP3 can be voiced through gain structuring and th...

Страница 13: ...ound doesn t improve then put the new tubes back in the boxes and try again in 6 months You can think tube replacement for your CSP3 in 3 levels 1 The first tube to replace is the rectifier If it s ge...

Страница 14: ...ncluded Consumption 65 watts Input jacks RCA Output jacks RCA Headphone jacks dual 1 4 4 pin XLR or 3 pin XLR Warranty lifetime to original owner 90 days on tubes Service For service please contact us...