background image

4

WARNING:

 
Procedures and techniques if not care-
fully followed - will result in damage to the 
equipment. - will expose the user to the risk 
of serious injury, illness or death. 

This electric fireplace heater is for use on 
120 volts. The cord has a plug as shown at 
A in illustration below. An adapter as shown 
at C is available for connecting three-blade 
grounding-type plugs to two-slot recep-
tacles. The green grounding plug extending 
from the adapter must be connected to 
a permanent ground such as a properly 
grounded outlet box. The adapter should not 
be used if a three-slot grounded receptacle 
is available. 
A 15 AMP circuit is required to operate this 
heater. If the breaker trips when the heater 
is used then you may need to move the 
heater to another location or unplug other 
appliances that are on the same circuit. If 
you require an extension cord use one that 
is rated at 1875 watts. 

S A F E T Y   I N S T R U C T I O N S

Содержание M100-25FAO

Страница 1: ...location for the fireplace heater that is protected from direct sunlight 2 Do not plug the unit into the power outlet before you read all instructions ELECTRIC FIREPLACE HEATER I N S T R U C T I O N M A N U A L M100 25FAO ...

Страница 2: ...he electric fireplace heater may emit a slight harmless odor when first turned on This is caused by activating the internal heater components for the first time and should not occur again 1 Read all instructions before using this electric fireplace heater 2 This electric fireplace heater is hot when in use To avoid burns do not let bare skin touch hot surfaces The grill directly in front of the he...

Страница 3: ...manufacturer may cause fire electric shock or injury to persons 15 Avoid the use of an extension cord because the extension cord may overheat and cause a risk of fire However if you have to use an extension cord the cord shall be No 14 AWG minimum size and rated not less than 1875 watts S A F E T Y I N S T R U C T I O N S 16 Do not plug this product into a receptacle controlled by a wall switch or...

Страница 4: ...pe plugs to two slot recep tacles The green grounding plug extending from the adapter must be connected to a permanent ground such as a properly grounded outlet box The adapter should not be used if a three slot grounded receptacle is available A 15 AMP circuit is required to operate this heater If the breaker trips when the heater is used then you may need to move the heater to another location o...

Страница 5: ...eels R to Base with 16 Small screws S See Fig A A S S E M B LY I N S T R U C T I O N S PARTS LIST Fireplace insert 1 A Top panel 1 B Base 1 C Front panel 1 D Left front panel 1 E Right front panel 1 F Left side panel 1 G Right side panel 1 R Wheels 4 S Small screws 16 T Medium brackets 3 U Mounting brackets 2 V Medium KD screws 5 W KD screws 48 X Plastic connectors 16 Y SELF REPAIR SET Touch up re...

Страница 6: ...s for each connector See Fig B Fig B Step 3 Attach Left side panel F to Left front panel D with 2 KD screws Attach Right side panel G to Right front panel E with 2 KD screws See Fig C Fig C Step 4 Attach Left front panel D and Left side panel F to Base B with 3 KD screws Attach Right front panel E and Right side panel G to Base B with 3 KD screws See Fig D Fig D Step 5 Attach Front panel C to Left...

Страница 7: ...er is against the mantel Step 2 Attach top side of the insert with 3 Med bracket T and 3 Med KD screws V Attach 2 Mounting Brackets U at the bottom side of insert with 2 Med KD screws See Fig G Fig G Step 3 Move assembled unit to desired location Unit should not be positioned in area exposed to direct sunlight WALL ANCHOR SAFETY CABLE The use of WALL ANCHOR SAFETY CABLE is highly recommended in or...

Страница 8: ...f 1875 WATTS Once the fireplace insert has been properly connected to a grounded electrical outlet it is ready to operate OPERATION BY THE CONTROL PANEL The controls are located behind the grill below the front glass and can be accessed by pulling the grill from the top forward and down O I Press this button for main power and flame effect The indicator light will turn on See below for other contr...

Страница 9: ...bulb wattage REPLACING THE FLAME EFFECT LIGHT AND LOG SET LIGHT BULBS Step 1 Remove 12 screws on the back of fireplace and open the rear cover There are 2 larger screws and 10 smaller screws Step 2 You will find 1 X 40W Type B 10 bulb under log set bed Step 3 Loosen and remove the burnt out bulb and replace with new bulb Step 4 Close the rear cover Secure the 2 larger screws into the top left corn...

Страница 10: ...TS KD SCREWS and PLASTIC CONNECTOR 1 Place the PLASTIC CONNECTOR on the mantel unit and mark the drill holes as shown in Fig B Fig B 2 Drill the holes with diameter 3 4 inches 10 mm and depth 3 4 inches 10mm on the mantel Each Plastic Connector needs 3 holes See Fig C Fig C Fig D 3 Gently install the KD NUTS into the drilled holes with hammer as shown in Fig D 4 Attach the PLASTIC CONNECTOR and lo...

Страница 11: ...fireplace heater is tested before it leaves the factory and it is guaranteed for one year If the unit should fail to operate correctly within one year from the date of purchase call customer service at 1 800 459 4409 EST We will at our discretion either repair or replace the unit It will have to be returned to us freight prepaid and we will return the repaired or re placed unit to you freight prep...

Отзывы: