5 Technical description
5.1 Use according to the regulations
By asbestos sanitation works within closed rooms, you have to exclude that the asbestos
fibres leave the area of operation uncontrolled and endanger the human health and the
environment. For this reason, persons must leave the area of operation through a lock
system and take a shower before they exit.
The deconta water treatment assumes the heating of the shower water and takes over
the filtering of the contaminated sewage water
5.2 Device description water treatment
The built-in geyser in the water treatment provides the heating of shower water. The
sewage pump will automatically start along with the shower process. This sucks out the
waste water from the shower. Through a pre-filter and two fine filters, the wastewater is
cleaned so far that it can be fed to a sewer.
Sewage pump
Geyser
Fine filter
Pre-filter with support
core and sieve
Pressure switch filter monitoring
Manometer Filter
monitoring