background image

 

Instruction manual 

 

Water Management Boiler System C 110 L 110V 

 

 

 

 

 

Seite 5 

 

3 Volume of delivery 

 
If no other agreements have been made, the scope of delivery of the water management 
unit consists of: 
 

 Water Management System 

 Filter 

 Instruction manual 

 
 

Return delivery after termination of rental period 

 
We have to insist on following conditions for the return delivery in order to protect our 
clients and in accordance with the rules for hazardous materials transportation: 
 

  As listed above 

  Well cleaned (ready for use) 

  Without binder remains 

 Without 

damages 

 Without 

filter 

 
 

4 Technical description 

 

4.1 Intended use 

 
During asbestos sanitation works within closed rooms, you have to exclude that the 
asbestos fibres leave the sanitation area uncontrolled and endanger the human health 
and the environment. For this reason, personnel must leave the sanitation area through a 
lock system and take a shower while leaving. 
 
The deconta water treatment assumes the heating of the shower water and takes over 
the filtering of the contaminated sewage water. 
 

4.2 Unit description 

 
This is an electric warm water storage for the heating of shower water. The filling of the 
tank may be done via the filling port (bucket) or automatically with a permanently 
connected fresh water hose. An electrical heating rod warms the water to shower 
temperature (factory-adjusted approx. 37°C). The produced shower water is pumped out 
and 3-stage filtered. 
 
 
 

Содержание C110 L 110V

Страница 1: ...Instruction manual Water Management System C 110 L 110V Manufacturer deconta GmbH Im Geer 20 D 46419 Isselburg Description Water Management System C 110 L 110V Type No 602 Serial No...

Страница 2: ...ery 4 2 2 Transport 4 2 3 Storage 4 3 Volume of delivery 5 4 Technical description 5 4 1 Intended use 5 4 2 Unit description 5 5 Technical data 6 6 Initial operation 7 7 Maintenance and care 9 7 1 Dai...

Страница 3: ...e event of non observance deconta assumes no liability To ensure safety during operation of the unit the following must be strictly observed Do not use in potentially explosive areas Necessary repairs...

Страница 4: ...nt to avoid exposure to violent shocks otherwise the function and safety of the unit cannot be guaranteed In winter and at risk of frost the whole unit Pump filter housing and tank needs to be emptied...

Страница 5: ...During asbestos sanitation works within closed rooms you have to exclude that the asbestos fibres leave the sanitation area uncontrolled and endanger the human health and the environment For this rea...

Страница 6: ...e service water 110 Liter Tank filling automatic or manually via filling port Heating capacity 1000 W Filter stages 3 Filter size 10 Power connection 100 120 V Power consumption 7 A Water connections...

Страница 7: ...etwork or fill manually via filling port o Connection Warm water shower water with shower top o Connection Sewage IN with shower tray o Connection Sewage OUT with sewage system Connect to power supply...

Страница 8: ...tion Shower water pump waste water pump and heating rod active Safety instructions During works on the device always disconnect the plug Operate the device only with mains which are secured with fault...

Страница 9: ...r dirt Control of fine filter via manometer 7 2 Filter change The Manometer controls the fine filter We recommend a filter change at approx 3bar Attention Change Filter only when device is switched of...

Страница 10: ...e first use Repairs and maintenance may only be executed under the observance of all relevant safety measures All the filters mentioned have to be disposed of according to the legal terms 7 3 Reductio...

Страница 11: ...move hoses Remove fastening screw of pressure switch ATTENTION Do not alter the middle adjusting screw Remove fastening screw of pump head and take off the head Remove Valve plate and clean on front a...

Страница 12: ...Instruction manual Water Management Boiler System C 110 L 110V Seite 12 8 Circuit diagram...

Страница 13: ...GmbH Im Geer 20 D 46419 Isselburg Product Water Management C 110 L Type 602 The design of the unit complies with EU Machine directive 2006 42 EG the following directives EU Low voltage directive 2006...