Instruction manual 

 

Negative Pressure Monitor 

 

aircontrol S 110V

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Manufacturer:   deconta 

GmbH 

 

 

 

 

Im Geer 20, D - 46419 Isselburg 

 
Description / Type No.: 

aircontrol S 1  110V

  

Type  608 

 
    aircontrol 

 

110V 

 

Type  603 

 
    aircontrol 

 

110V 

 

Type  609 

aircontrol S 1 

aircontrol S 2 

aircontrol S 3 

Содержание aircontrol S 1

Страница 1: ...re Monitor aircontrol S 110V Manufacturer deconta GmbH Im Geer 20 D 46419 Isselburg Description Type No aircontrol S 1 110V Type 608 aircontrol S 2 110V Type 603 aircontrol S 3 110V Type 609 aircontrol S 1 aircontrol S 2 aircontrol S 3 ...

Страница 2: ...e upgrades 7 6 3 Terminal assignment potential free alarm contact 8 7 Initial operation 8 7 1 Telealarm GSM inserting a Sim Card 9 7 2 Standby function 10 8 Display indication 11 8 1 aircontrol 11 8 2 Telealarm 12 9 Settings operation 13 9 1 Possible settings Code chart aircontrol 14 9 2 Possible settings Code chart Telealarm 15 10 Extension modules 16 10 1 Additional measuring channels 16 10 2 Pr...

Страница 3: ...tee Stability long life and serviceability on site Mechanics with kick Pleasing design The copyright of this instruction manual remains with deconta This manual is intended for assembly operation and maintenance personnel It contains instructions and drafts of technical nature which may neither be distributed nor used in any unauthorised way for competitive purposes or passed on to others For more...

Страница 4: ...2 Operation In order to ensure the safety during the operation of the device the following must be observed Do not place in an explosive area Necessary repairs maintenance and cleaning in particular in the field of electrical equipment has to be realized only by qualified staff The safety and protective equipment has to be kept in perfect functioning Attached safety instructions have to be kept in...

Страница 5: ...sed by improper handling or carelessness it is common practice to handle the Transport with care 3 2 Transport In order to protect the device during the transport it is located in a transport box Care must be taken to ensure the device is not exposed to impacts or blows because otherwise the function and safety of the device cannot be guaranteed 4 Scope of delivery If no other agreements have been...

Страница 6: ...ce for 4 extension modules aircontrol S 2 offers space for 10 extension modules aircontrol S 3 offers space for 5 extension modules and is provided with an additional automatic telephone device Telealarm GSM to initiate an alarm via the mobile phone network as well as with integrated connectible sockets for Standby units For the calibration or service it is sufficient to change the concerned modul...

Страница 7: ...xtension slots 4 10 5 6 2 Basic equipment and upgrades S 1 S 2 S 3 Powder coated lockable housing Large display with light Keyboard vandal proof Dry alarm contact e g for external Telealarm GSM Alarm plug 100 120 V 16 A Connectible socket 100 120 V 16 A for Standby units Measuring connec tion for tube 8 x 1 mm 1 piece measuring channel Telealarm GSM integrated Art No Additional measuring channels ...

Страница 8: ...e to be screwed down tightly The measuring tubes may not be flexed or damaged Do not place the measuring tube in an area where they can be pressed together Do not expose the reference connection to dynamic pressure ratios e g wind The device has to stand horizontally on an even surface Do not expose the device in operational state to any vibrations or shocks Short tube lengths shorten the response...

Страница 9: ... inserting of Sim Card only aircontrol S 3 If the Sim Card is protected by a PIN Number this Number must be saved in the Telealarm before the Sim Card is inserted Enter 20 see Code chart Switch off unit and pull power plug Loosen screws of protective cover and take off cover Press on the yellow button with a sharp pointed object e g ballpoint pen Push out the Sim Card Holder and remove from slot I...

Страница 10: ...ure in the removal area that is too low constant alarm via X seconds adjustable at aircontrol an integrated Standby mode is activated The Standby Negative pressure unit is supplied with power by its connection to one of the blue sockets After the completion of the alarm the Standby Negative pressure unit keeps on running and is switched off via a code entry Code chart aircontrol Code 61 only after...

Страница 11: ...ctual time Top right Alarm status Possible alarm status indications A100 Alarm evaluation deactivated A101 Alarm evaluation is activated no alarm has been identified A102 Alarm low identified the delay time is running 103 Alarm high identified the delay time is running A104 External alarm identified the delay time is running A112 Alarm low identified the delay time has expired A113 Alarm high iden...

Страница 12: ... but not logged in S505 Searching for available GSM Network S510 home network logged in GSM Network S511 logged in GSM Network Roaming Top right Alarm status Possible Alarm status indicators A100 Alarm analysis deactivated A101 Alarm analysis is activated no alarm detected A102 Alarm detected delay time is running A103 Delay time is expired Call is effected A104 Calls have been executed Middle Nam...

Страница 13: ...are always carried out according to the same procedure via the keypad Push the key C will appear on the display Enter the code for the relevant adjustment see following Code chart Push the key The actual adjusted value is indicated Enter a new value Confirm the entry with the key ...

Страница 14: ...0 Time in hours 00 23 41 Time in minutes 00 59 42 Date day 00 31 43 Date month 01 12 44 Date year 00 99 50 Print out every X minutes 0 off 0 240 minutes 51 Memory interval all X minutes 1 240 minutes 52 Number of memory data sets which should be transferred on a USB Stick 0 9998 53 Memory delete 0 cancel 1 delete 60 Switching status alarm socket after alarm only at S 3 0 inactive 1 active 61 Reset...

Страница 15: ...Phone number 2 13 Phone number 3 14 Phone number 4 15 Phone number 5 19 Delete all saved phone numbers 0 cancel 1 delete 20 PIN Number of Sim Card 4 digit 31 Delay time alarm message 0 999 seconds 40 Number of redials 0 9 41 Time in between redials 0 999 seconds 42 Stop dialling after receipt of call 0 after first contact 1 choose all numbers Note To delete a recorded message a new message without...

Страница 16: ...n be upgraded or managed in addition to the existing measuring channel For the aircontrol S 3 5 more measuring channels can be upgraded or managed in addition to the existing measuring channel 10 2 Printer module occupies 3 free extension slots With the help of the printer module the measuring values can be recorded and documented archive safe on normal paper rolls Change of paper and ink ribbon C...

Страница 17: ...Open printer cover Push on the field marked Push The ribbon comes off Change the ribbon 10 3 Emergency battery only for aircontrol S 2 S 3 occupies no slots When battery is fully charged the Negative Pressure Monitor can maintain the measuring during a period of approx 2 3 h without power supply In battery mode the display backlight and the printer module are switched off An indication regarding t...

Страница 18: ...04 10 23 29 1 24 2 24 3 13 4 12 5 0 6 0 7 0 8 0 28 04 10 22 29 1 23 2 27 3 13 4 11 5 0 6 0 7 0 8 0 28 04 10 21 29 1 25 2 24 3 14 4 11 5 0 6 0 7 0 8 0 28 04 10 20 29 1 22 2 24 3 14 4 13 5 0 6 0 7 0 8 0 28 04 10 19 29 1 21 2 24 3 15 4 13 5 0 6 0 7 0 8 0 28 04 10 18 29 1 22 2 26 3 13 4 12 5 0 6 0 7 0 8 0 28 04 10 17 29 1 24 2 23 3 12 4 11 5 0 6 0 7 0 8 0 28 04 10 16 29 1 22 2 24 3 16 4 13 5 0 6 0 7 0...

Страница 19: ...9 04 10 01 29 1 26 2 25 3 17 4 13 5 0 6 0 7 0 8 0 29 04 10 00 29 1 25 2 26 3 16 4 12 5 0 6 0 7 0 8 0 28 04 10 23 29 1 24 2 24 3 13 4 12 5 0 6 0 7 0 8 0 28 04 10 22 29 1 23 2 27 3 13 4 11 5 0 6 0 7 0 8 0 28 04 10 21 29 1 25 2 24 3 14 4 11 5 0 6 0 7 0 8 0 28 04 10 20 29 1 22 2 24 3 14 4 13 5 0 6 0 7 0 8 0 28 04 10 19 29 1 21 2 24 3 15 4 13 5 0 6 0 7 0 8 0 28 04 10 18 29 1 22 2 26 3 13 4 12 5 0 6 0 7...

Страница 20: ...Isselburg Product Negative Pressure Monitor Type 603 608 609 The design of the units complies with the EU Machine directive2006 42 EG following directives EU Low voltage directive2006 95 EG EU Directive89 336 EWG Applied harmonised standards EN 60335 1 Applied national standards DIN VDE 0701 DIN VDE 0702 W Weßling Isselburg 10 04 2013 ...