background image

Due to the high temperature of the fireplace surfaces, keep children and pets at a safe distance. 

Do not use the unvented decorative fireplace to heat or boil water or use as a cooking appliance. 

Do not use in a room with oxygen tanks. 

Risk of Indoor Air Pollution – Use the unvented decorative fireplace only in a well-ventilated 

area and with doors of adjacent rooms open. Do not obstruct air flow to the fuel holder box by 

piling logs over

the fuel reservoir or in any other way with any other material.  People with breathing problems 

should consult a physician before using the unvented decorative fireplace. 

The following or equivalent information for provision of combustion and ventilating air for un-

vented decorative devices: ‘’In a house of typical construction, that is, one that is not of un-

usually  tight  construction  due  to  heavy  insulation  and  tight  seals  against  air  infiltration,  an 

adequate  supply  of  air  for  combustion  and  ventilation  is  provided  through  infiltration.”   The 

unvented decorative appliance should not be used in a small room where less than 5.7 m

3

 (200 

ft

3

)

 

of air space is provided for each 1000 Btu per hour of the unvented decorative device rating 

(considering the maximum burner adjustment).  Do not use the unvented decorative fireplace in 

a bathroom, a room where sleeping accommodation is provided or any other small room.

Make sure that the shut off device works properly before lighting.

INSTALLATION OF THE WALL MOUNTED FIREPLACE AND BURNER

Models 

ARC 103A & VAGUE 101A

 are wall-mounted. 

A horizontal support and two vertical supports are provided with the fireplace.
Determine the location of your fireplace. It must be located at a minimum of 12’’ above the 

floor, at a minimum of 24’’ from the ceiling, and allow a clear distance of 12’’from the right and 

left edge of the unit. 

To attach the hanging support, refer to the drawing for installation

.

Locate 2 wall studs (obligatory), that are at 16’’ center to center.

Attach the horizontal support (no 1) using a bubble level tool with 2 no.12 x 1 ½’’ wood screws 

(no.4).

Hang  the 2 vertical straps (no.2) on the hooks of the horizontal support (no.1) and ensure that 

they are square.  Add brackets (no. 3) to the bottom of the vertical supports, attach them with 

Содержание ARC 103A

Страница 1: ... Wall Mounted Fireplace Models ARC 103A VAGUE 101A CONTENTS Safety instructions p 2 Wall mounted fireplace installation p 3 Burner installation p 3 Burner p 3 Combustible Fuel p 4 Instructions p 4 General rules Filling Lighting Extinguishing While using Cleaning the burner p 5 Cleaning the fireplace p 5 Warranty p 6 ...

Страница 2: ...ace is for decorative purposes only and not to be used as your main heat source Keep children and pets away while operating the fireplace especially while lighting it up Caution If your wall is covered with wallpaper wood varnish or other flammable material you must use a fire proof backing on the wall Any furniture curtains or other flammable materials must be located at a safe and secure dis tan...

Страница 3: ...decorative fire place is functioning or still hot Do not fill the fuel reservoir completely and use the adjustable pourer to do so If the deco fuel fuel spills out of the reservoir wipe it with an absorbent paper before lighting Continually monitor the device as soon as the fire is started The steel elements of the fireplace can become very hot while the combustible fuel is burning Never touch the...

Страница 4: ...appliance should not be used in a small room where less than 5 7 m3 200 ft3 of air space is provided for each 1000 Btu per hour of the unvented decorative device rating considering the maximum burner adjustment Do not use the unvented decorative fireplace in a bathroom a room where sleeping accommodation is provided or any other small room Make sure that the shut off device works properly before l...

Страница 5: ...acity when the damper is completely open You can increase the length to 5 hours by reducing the flames height by simply moving the damper forward The burner elements are removable and must be installed in the fireplace according to the instruc tions before ignition The fuel must be poured into the burner reservoir If any spatters occur make sure to clean them before lighting the fire COMBUSTIBLE F...

Страница 6: ...vel indicator maximum of 1 5 Litres Do not overflow or splash around the reservoir If any spatters occur clean them with a rag or a paper towel in order to absorb the excess Do not throw this rag or paper towel in the garbage let it dry and keep it away from the fire children and pets then dispose of it Only use decofuel fuel LIGHTING The damper must be completely open The fuel must be kept at roo...

Страница 7: ...fireplace or the burner while it is in operation serious burns may occur EXTINGUISHING Keep the glass doors closed Pull the damper completely closed WHILE USING Constantly monitor the device as soon as the fire has been started Have a class B fire extinction device nearby In case of a burn call the nearest hospital Consult a Doctor if in doubt of any severe burn Igniting the fireplace implies that...

Страница 8: ...n material or workmanship and commits to reparing or replacing at decoflame s dis cretion any defective product free of charge within 2 years from the date of purchase A proof of purchase such as a dated sales receipt sales slip etc indicating the model and serial number will be required before any intervention from our dealers will be made on the guaranteed product You are obligated to meet the d...

Страница 9: ...INSTALLATION OF THE WALL MOUNTED FIREPLACE AND BURNER ARC 103A ...

Страница 10: ...INSTALLATION OF THE WALL MOUNTED FIREPLACE AND BURNER VAGUE 101A ...

Отзывы: