Страница 2: ...TIONAL REMARKS 11 PURITY VALUE AND FLOW FUNCTIONS CHART 12 T E C H N I C A L PA R A M E T E R S 1 3 COMPONENTS NAME AND FUNCTIONS DESCRIPTION 14 15 T R O U B L E S H O O T I N G 1 6 C L E A N I N G A N D M A I N T E N A N C E I N S T R U C T I O N S 1 7 FA U LT A N D R E PA I R I N G C O M PA R I S O N TA B L E 1 8 ELECTROMAGNETIC IMMUNITY 19 20 WARRANTY 21 22 MANUFACTURER INFORMATION 23 TABLE OF ...

Страница 3: ...functioning of your device We kindly request your special consideration towards the IMPORTANT SAFEGUARDS listed in here Note Some illustrations in this manual may not be exactly the same as the device in your possession Our product is fully equipped You will find a humidification bottle oxygen tubes oxygen masks air intake filtering foam in your package However these components should only be selecte...

Страница 4: ...away from the bathroom 2 We recommend to keep the p nasal oxygen tube less than 11 meters in length 3 Do not place or store the nasal oxygen tube in a condition where it is susceptible to drop into water or any other liquid It should always be kept clear and stored in appropriate sanitary conditions 4 The display screen by default denotes the number of hours of usage of the device 5 Oxygen causes ...

Страница 5: ...our device under the conditions of strong magnetic field environment It should be placed in a clean dust free non corrosive and non poisonous environment 9 The product should be placed in a well ventilated environment and the air source inlet should be in a place at the least exposure to pollutants like burning gas exhaust system air vents anaesthesia vacuum exhaust ports etc 10 Do not use the powe...

Страница 6: ... humidification water bottle should ideally be cleaned and sterilized every 2 3 days of usage In warmer climatic conditions and monsoon season it is recommended to clean and sterilize the bottle daily While not in use please keep the bottle dry and empty While replacing your nasal oxygen tube please replace it with a genuine one of the same specifications that comes with your device Please contact...

Страница 7: ... refer to the table given below Waste Electrical and Electronics Equipment Directive 2002 96 EC WEEE DIRECTIVE To scrap or do away with your machine always contact your local supplier or the manufacturer for Serial Number This way up RELATED USE SYMBOL DESCRIPTION 6 ...

Страница 8: ... PACKING LIST After receiving your product please open the package carefully This product is packed meticulously with an upper and lower foam protection cover If the protective cover of your package is damaged immediately check if your device has endured any damages or not Please check if any of the below mentioned components or accessories are missing Notify your local supplier or the manufacture...

Страница 9: ...om the wall Ensure that there is a normal airflowat the bottom of the oxygen concentrator which will maintain the normal heat and functioning of your device 2 Attach the humidification bottle in the marked space of your oxygen concentrator and operate it as per following instructions A Fill the humidification bottle with distilled water as per the marked water level on the bottle Fix the lid properly...

Страница 10: ...cilitate oxygen inhalation Refer Figure 3 Detach the humidification bottle from your device when not in use Elastic band F If the oxygen concentrator s alarm rings while the device is switched on please check if the power supply connection is loose or if the external power supply has been interrupted G After the user is done taking the oxygen therapy please turn the power switch off Kindly clean and...

Страница 11: ...ttle nasal oxygen tube andAir Intake Filtering Foam SCOPE OF USE APPLICATION MO2 Oxygen Concentrator is suitable for composing medical oxygen which is intended to provide supplemental oxygen to people requiring low flow oxygen therapy This device is not intended to be life supporting or life sustaining SURROUNDING CONDITIONS REQUIREMENTS 1 OperatingTemperature 5 C 40 C 2 Operating Relative Humidity...

Страница 12: ...Nitrous Oxide anaesthetic mixture case when do not use of flammable gas and air mixed with oxygen or Nitrous 5 Oxide or anaesthetic mixture under the condition of the equipment classification according to the operation mode Continuous operation 6 No signal output and signal input part Usage Voltage 230V 50Hz 7 Working Rest the concentrator for 20 30 min after continuous usage for 7 to 8 hrs 8 Oxygen...

Страница 13: ...PURITY VALUE AND FLOW FUNCTION CHART output pressure 0 Purity and value flow funtions chart Figure 4 PURITY VALUE AND FLOW FUNCTION CHART 12 ...

Страница 14: ...te 0 to10 Liter Per Minute Less than 55 dB A L 400 W 300 H 540 mm Ÿ When purity 80 the red indicator will flash 10c on page 16 This will switch off when purity is 80 When purity 80 for more than 3 minutes the last red indicator 10d on page 16 alarm will flash Ÿ In case red indicator light 10d on page 16 Flashes please turn off at once arrange spare oxygen contact the supplier or the manufacturer Param...

Страница 15: ... It filters and prevents dust dirt fibres and microparticles from entering the oxygen concentrator 4 HEATSINK Located at the bottom of the oxygen concentrator this heat sink should not be blocked while the machine is running This helps maintain the normal heat and functioning of your oxygen concentrator 5 THEAC POWER CORD WITH PLUG 6 CASTOR WHEELS 4 Facilitates the mobility of the oxygen concentrato...

Страница 16: ...litres The oxygen flow will reduce if the flow meter is rotated in the clockwise direction and will eventually shut down the flow of oxygen If turned in the counter clockwise direction the oxygen flow will increase MO2 OXYGEN CONCENTRATOR 15 9 LED Display Reference figure 8 a Green power indicator light Start operatingt b Green indicator light Oxygen output normally c Red indicator light Low Purity d R...

Страница 17: ... 3 minute If your oxygen concentrator displays Low Pressure red indicator light will shine with a continuous alarm tone NOTE All the alarm settings have been programmed to low priority This alarm system setting has been set up during the manufacturing process and cannot be changed by a user 1 In case of the call service alarm kindly check the connection status of the power supply 2 If your oxygen ...

Страница 18: ...ing a dry cloth towel 2 The Water Humidification Bottle You can use detergent and hot water to clean the humidification bottle Alternatively you can also use white vinegar and water plus fungicides in the ratio of 1 3 leave the solution in the humidification bottle roughly for 30 minutes follow it up with rinsing it with hot water and leave it to dry completely CLEANING AND MAINTENANCE INSTRUCTIONS 1...

Страница 19: ...pull FAULT AND REPAIRING COMPARISON TABLE 18 ...

Страница 20: ...ance calculated from the equation applicable to the frequency of the transmitter Recommended separation distance D 3 5 V1 P D 3 5 E1 P 80 MHz to 800 Mhz Conducted RF IEC 61000 4 3 3 V m 80 MHz to 2 5 GHz 3 V m D 7 E1 P 80 MHz to 2 5 GHz According to the transmitter manufacturer Here p is the maximum output power rating of the transmitter in watts W d is the recommended separation distance in metre...

Страница 21: ...liance level above the MO2 oxygen concentrator should be observed to verify normal operation If abnormal performance is observed additional measures might be necessary such as reorienting or relocating the MO2 oxygen concentrator B Over the frequency range 150 kHz to 80 MHz the magnetic field strength should be less than 3 V m ENVIRONMENTALMONITORING 3 Treatment of waste and residue Do not discard ...

Страница 22: ... features The following conditions are not free of maintenance i Products over the warranty period ii Failure to operate as per stated user manual guidelines iii Failure scratch or damage caused by moving the oxygen concentrator iv If the repair decomposition assembling is carried out without allowance and assistance from professional personnel v Normal damage due to routine wear and tear of the m...