1-5
1.5 Check Burner Manifold Pressure
WARNING
This task should be performed by qualified service personnel only.
1. Ensure that the gas valve knob is in the "OFF" position (non-CE), or press red button to turn gas
valve off (CE).
2. Remove the pressure tap plug from the gas valve (see illustration below).
3.
Insert the fitting for a gas pressure-measuring device into the pressure tap hole.
4.
Place the gas valve in the "Pilot" position (non-CE), or press white button and light pilot (CE).
After the pilot is lit (turn non-CE gas valve to "ON" position), set thermostat knob to 350°F
(177°C). When the burner lights and continues to burn, note gas pressure reading for correct
pressure in accordance with the table on page 1-1.
5.
To adjust burner gas pressure, remove the cap from the gas valve regulator and adjust to correct
pressure.
6.
Place the fryer power switch and the gas valve in the "OFF" position. Remove the pressure-
measuring device fitting from the pressure tap hole and reinstall the pressure tap plug.
7.
Repeat step 4 to continue fryer operation.
Pressure tap locations on CE gas valves (left) and non-CE gas valves (right).