background image

4

Checking Temperature

A.

 

Check the cooking oil/shortening temperature at any time by pressing the 

 switch once.

Check the setpoint by pressing the 

 switch twice.

B.

 

During the idle periods, when the fryer is on but not in use, "

" should appear on both

displays on a single frypot computer.  "

" will appear on the display of the side that is

turned on in a split-vat computer.  If not, check actual temperature and setpoint.

C.

 

If you suspect a defective probe, check the cooking oil/shortening temperature with a
thermometer.  Verify that the computer readout is reasonably close to your measured reading.

NOTE: The electronic circuitry can be affected adversely by current fluctuations and electrical
storms. If for no apparent reason the computer does not function or program properly, reset the
computer by unplugging the power cord and plugging it back in.

Programming The Dean Compu-Fry Computer

1.

 

Activate the computer by pressing either 

 switch.

2.

 

To enter the program mode, first press the 

 switch. 

 will appear in the left display. If

you have pressed this switch in error and do not wish to program, press the 

 switch again.

Note: The computer will flash 

 

if cooking is in progress.

3.

 

Press 

  

  

  

  

(1 6 5 0) in that sequence to enter the program mode.

4.

 

  (Setpoint) will appear in the left display. This is for setting the cooking temperature. The

temperature previously selected will be displayed in the right display. Enter new temperature.
Press the 

 switch to lock in temperature setting.  If the setting is correct, press the 

 switch to

advance to the next programming option.

5.

 

 (Select Product) will appear in the left display. Press the product button to be

programmed.

6.

 

 will appear in the left display.  The sensitivity number previously selected will be

displayed in the right display.  Enter the new desired sensitivity number, the range is 1 to 9.
Enter "0" for no sensitivity.  Press the 

 switch to lock in the setting.

Sensitivity adjusts computer-cooking time to compensate for the drop in cooking oil/shortening
temperature when a basket of product is placed into the fryer. Sensitivity decreases or
increases cooking time to counterbalance variances in product density, basket-load size, and
initial temperature. A proper sensitivity setting will ensure a high quality product. For example:
4 ounces of fries can be programmed to cook to the same quality as 2 pounds. A good initial
setting is 4 or 5.  Some experimenting with the range of 1 to 9 may be required to achieve
optimum quality.

Содержание Computer Dean Compu-Fry

Страница 1: ...f the Commercial Food Equipment Service Association recommends using CFESA Certified Technicians 24 Hour Service Hotline 1 800 551 8633 NOVEMBER 2001 8195865 Dean Compu Fry Computer Operating Programming Instructions ...

Страница 2: ...G INSTRUCTIONS 1 EQUIPMENT SETUP AND SHUTDOWN PROCEDURES 2 Setup 2 Shutdown 2 Operating the Fryer 2 Checking Temperature 4 PROGRAMMING THE DEAN COMPU FRY COMPUTER 4 Boil Feature 5 Fryer Recovery Time Check 6 Temperature Selection Fahrenheit to Celsius 6 Constant Oil Temperature Display Mode 6 ...

Страница 3: ...ture when depressed Old style computers will have this switch 4 5 Power Switches either switch turns power ON or OFF Old style computers will have this switch 6 7 Product and Coding Switches provides access to computer and programming functions Old style computers will have these switches 8 Programming Switch used when reprogramming the computer memory Old style computers will have this switch WAR...

Страница 4: ...s programmed cooking temperature It may be necessary to add vegetable oil to bring the level up to the proper mark after the oil has reached the programmed cooking temperature If solid shortening is used the MELT cycle MUST be used to melt the shortening It may be necessary to add solid shortening to bring the level up to the proper mark after the packed shortening has melted DO NOT DISABLE OR CAN...

Страница 5: ...ween digits 1 and 2 will illuminate indicating that the computer is cycling the burners ON C Cook cycle operation is initiated by pressing the product switch 1 The basket lift on fryers so equipped will lower the product into the cooking oil shortening 2 The display will indicate the programmed cook time and begin countdown 3 If shake time is programmed you will be notified to shake the product X ...

Страница 6: ...r will flash if cooking is in progress 3 Press 1 6 5 0 in that sequence to enter the program mode 4 Setpoint will appear in the left display This is for setting the cooking temperature The temperature previously selected will be displayed in the right display Enter new temperature Press the switch to lock in temperature setting If the setting is correct press the switch to advance to the next prog...

Страница 7: ...inutes Press the switch If you do not wish to use the hold time enter 0 and press the switch 10 will appear in the left display If you desire to program more products return to Step 5 If no more programming is required lock in program by pressing the switch 14 will now appear in the left display A previously entered cook time will appear in the right display If that time is correct press the switc...

Страница 8: ...o change the computer temperature from Fahrenheit to Celsius or Celsius to Fahrenheit press either switch 2 Press the switch will appear in the left display 3 Enter 1 6 5 8 in that sequence The computer will automatically convert the temperature from Fahrenheit to Celsius or Celsius to Fahrenheit 4 Press the switch to display the temperature in the newly selected mode Constant Oil Temperature Disp...

Страница 9: ...7 THIS PAGE INTENTIONALLY LEFT BLANK ...

Страница 10: ...ort Louisiana 71135 1000 Shipping Address 8700 Line Avenue Shreveport Louisiana 71106 TEL 1 318 865 1711 FAX Parts 1 318 219 7140 FAX Tech Support 1 318 219 7135 PRINTED IN THE UNITED STATES SERVICE HOTLINE 1 800 551 8633 819 5865 NOVEMBER 2001 ...

Отзывы: