DECATHLON SERIES GAS FRYERS
CHAPTER 1: SERVICE PROCEDURES
1-39
1.8.7 Improper Basket Lift Function
(cont.)
Electronics failure.
This category encompasses problems with the relays, microswitches,
capacitors, resistors, interface board, wiring, and controls.
Troubleshooting the electronics of the modular basket lift is simply a process of verifying current
flow through the components up to and including the motor. Using a multimeter set to the 250 VAC
range, check the connections on both sides of the component for the presence of 120 VAC. The
simplified wiring diagrams on the preceding pages identify the components and wiring connection
points.
1.9 Troubleshooting
Guides
The following troubleshooting guides are intended to assist service technicians in quickly isolating
the probable causes of equipment malfunctions by following a logical, step-by-step process.
PROBLEM
PROBABLE CAUSES
CORRECTIVE ACTION
Burner will not ignite.
Light in ON/OFF switch
is not illuminated.
A.
ON/OFF switch is off.
A.
Turn ON/OFF switch on.
ON/OFF switch is on,
but the switch light is not
illuminated.
A.
No voltage at switch.
A.
Ensure line voltage is present at the
switch.
A.
Drain microswitch circuit (filter-
equipped units) is open.
A.
Ensure drain valve is fully closed and
microswitch is functioning. Replace
microswitch if defective.
B.
Voltage is present at ON/OFF switch,
but continuity of the switch in ON
position is not "0.”
B.
ON/OFF switch is defective. Replace
switch with a known working switch.
C.
Continuity of thermostat is not "0"
(oil temperature is at least 15°F below
electronic/ operating thermostat
setting).
C.
Thermostat(s) is/are defective.
Replace defective thermostat with a
known working thermostat.
ON/OFF switch is on and
the switch light is
illuminated, but there is
no output to gas valve.
D.
Gas valve is suspect.
D.
Go to "No burner flame" section.
Содержание CFD
Страница 47: ...DECATHLON SERIES GAS FRYERS CHAPTER 1 SERVICE PROCEDURES 1 42 Decathlon Dual Vat ...
Страница 48: ...DECATHLON SERIES GAS FRYERS CHAPTER 1 SERVICE PROCEDURES 1 43 Thermatron 24V ...
Страница 49: ...DECATHLON SERIES GAS FRYERS CHAPTER 1 SERVICE PROCEDURES 1 44 Thermatron 120V ...
Страница 50: ...DECATHLON SERIES GAS FRYERS CHAPTER 1 SERVICE PROCEDURES 1 45 Transformer Box ...
Страница 52: ...DECATHLON SERIES GAS FRYERS CHAPTER 1 SERVICE PROCEDURES 1 47 Dean Oil Return Wiring ...
Страница 54: ...DECATHLON SERIES GAS FRYERS CHAPTER 1 SERVICE PROCEDURES 1 49 Oil Return Left hand Normally Open Float Switch ...
Страница 55: ...DECATHLON SERIES GAS FRYERS CHAPTER 1 SERVICE PROCEDURES 1 50 Basket Lift with Timer 805 1411 ...
Страница 56: ...DECATHLON SERIES GAS FRYERS CHAPTER 1 SERVICE PROCEDURES 1 51 CM4 S with Constant Pilot ...
Страница 57: ...DECATHLON SERIES GAS FRYERS CHAPTER 1 SERVICE PROCEDURES 1 52 Chili s Wiring Diagram ...
Страница 58: ...DECATHLON SERIES GAS FRYERS CHAPTER 1 SERVICE PROCEDURES 1 53 Chili s Wiring with SCF Filtration ...
Страница 97: ...DECATHLON SERIES GAS FRYERS CHAPTER 2 PARTS LIST 2 39 2 10 Basket Lift Components D50 D60 and D80 Models ...