HIGH EFFICIENCY DECATHLON SERIES GAS FRYERS
CHAPTER 1: SERVICE PROCEDURES
1-12
1.7.2 Replacing the Temperature Probe; Controller-equipped Fryers
1.
Disconnect the fryer from the electrical supply.
2.
Drain cooking oil from the frypot. Allow the
frypot to cool completely before proceeding.
3.
Remove fryer door for easier access to the
temperature probe. First, remove top hinge
from bracket. Then, lift door off bottom
hinge pin.
4.
Disconnect the probe harness connector
(arrow). Use a pin pusher to remove plug
from probe wires (probe side only). Retain
the plug for re-assembly on new probe.
5.
Remove the drain manifold. Only the drain
tubes directly blocking the frypot being
replaced require removal.
-
Remove the nuts holding the drain valve
strap onto the drain tube stud.
-
Disconnect the Teflon tube at the back of
the center dump tube piece and any other
components attached to the tubes,
including drain flush flexlines.
-
Loosen the nut on each clamp holding the
rubber boots and drain sections together.
-
Carefully remove the tubes by pulling
down at an angle, straight out of the drain
valves, and working them gently out of
the rubber boots. Set aside for
reassembly.
Remove the nuts, Teflon tube (not pictured), clamp,
boot, and drain tubes.
Disconnect the two-pin probe harness
connector (arrow).
Remove the fryer door for easier access to the
temperature probe.
Содержание BK1814
Страница 46: ...HIGH EFFICIENCY DECATHLON SERIES GAS FRYERS CHAPTER 1 SERVICE PROCEDURES 1 41 1 10 5 BK1814 RAM Wiring Diagram ...
Страница 47: ...HIGH EFFICIENCY DECATHLON SERIES GAS FRYERS CHAPTER 1 SERVICE PROCEDURES 1 42 1 10 6 Filter Box ...
Страница 48: ...HIGH EFFICIENCY DECATHLON SERIES GAS FRYERS CHAPTER 1 SERVICE PROCEDURES 1 43 1 10 7 Thermatron Controller ...
Страница 52: ...HIGH EFFICIENCY DECATHLON SERIES GAS FRYERS CHAPTER 1 SERVICE PROCEDURES 1 47 1 10 11 FAST Controller India ...
Страница 53: ...HIGH EFFICIENCY DECATHLON SERIES GAS FRYERS CHAPTER 1 SERVICE PROCEDURES 1 48 1 10 12 KFC 1 Controller ...
Страница 54: ...HIGH EFFICIENCY DECATHLON SERIES GAS FRYERS CHAPTER 1 SERVICE PROCEDURES 1 49 1 10 13 CM4S Controller ...
Страница 67: ...HIGH EFFICIENCY DECATHLON SERIES GAS FRYERS CHAPTER 2 PARTS LIST 2 11 2 1 5 BK1814 Primary Components ...
Страница 74: ...HIGH EFFICIENCY DECATHLON SERIES GAS FRYERS CHAPTER 2 PARTS LIST 2 18 2 4 2 Drain Valve Assemblies ...
Страница 92: ...HIGH EFFICIENCY DECATHLON SERIES GAS FRYERS CHAPTER 2 PARTS LIST 2 36 2 12 Accessories 4 3 2 5 6 1 7 8 9 10 ...
Страница 97: ...THIS PAGE INTENTIONALLY LEFT BLANK ...