Operating Instructions for The Dean Forge Dartmoor Baker 5E Eco 

and Dartmoor Baker W5E Eco Stoves 

DMB5/DMBW5E issue 1. 21

st

 October 2019 

 

All stoves meet the essential type test requirement BS EN13240:2001 + 
A 2:2004 

 
The Clean Air Act 1993 and Smoke Control Areas

 

  
Under the Clean Air Act local authorities may declare the whole or part of the district of the authority 
to be a smoke control area. It is an offence to emit smoke from a chimney of a building, from a 
furnace or from any fixed boiler if located in a designated smoke control area. It is also an offence to 
acquire an 

“unauthorised fuel” for use within a smoke control area unless it is used in an “exempt” 

appliance (

“exempted” from the controls which generally apply in the smoke control area). 

  
The Secretary of State for Environment, Food and Rural Affairs has powers under the Act to 
authorise smokeless fuels or exempt appliances for use in smoke control areas in England. In 
Scotland and Wales this power rests with Ministers in the devolved administrations for those 
countries. Separate legislation, the Clean Air (Northern Ireland) Order 1981, applies in Northern 
Ireland. Therefore it is a requirement that fuels burnt or obtained for use in smoke control areas have 
been 

“authorised” in Regulations and that appliances used to burn solid fuel in those areas (other 

than 

“authorised” fuels) have been exempted by an Order made and signed by the Secretary of State 

or Minister in the devolved administrations. 
  
The Dean Stoves, Dartmoor Baker 5 Eco and Dartmoor Baker W5 Eco has been recommended as 
suitable for use in smoke control areas when burning wood logs. 
 
The Dean Stoves Dartmoor Baker 5 Eco and Dartmoor Baker W5 Eco is factory fitted with a 
permanent stop to prevent closure of the secondary air control for use in a smoke-controlled area 
 
Further information on the requirements of the Clean Air Act can be found here:  
 

http://smokecontrol.defra.gov.uk/

  

Your local authority is responsible for implementing the Clean Air Act 1993 including designation and 
supervision of smoke control areas and you can contact them for details of Clean Air Act 
requirements 

 
 
 
 
 
 

Содержание Dartmoor Baker 5E Eco

Страница 1: ...less fuels or exempt appliances for use in smoke control areas in England In Scotland and Wales this power rests with Ministers in the devolved administrations for those countries Separate legislation the Clean Air Northern Ireland Order 1981 applies in Northern Ireland Therefore it is a requirement that fuels burnt or obtained for use in smoke control areas have been authorised in Regulations and...

Страница 2: ...e fuels Dry wood 20 moisture content or below must be used Using wood with a moisture content above 20 will cause the stove to work inefficiently produce more smoke and particle emissions it will also cause the stove and flue to tar up and the door glass won t stay clean Wood is best seasoned by splitting it into a log and drying it for 2 years in a covered area so the air can pass through to dry ...

Страница 3: ...Wood Lay a fire of sticks and paper Firelighters can be used instead of paper Check the secondary air lever is fully open and the primary air spin wheel is partially open Light the paper or fire lighter and as it starts to establish a strong flame you may then fully open the primary air control When the fire has fully established and the logs are burning well this is usually about 10 to 20 minutes...

Страница 4: ... fuel use the primary air control as the main control When using a mixture of wood and coal balance the primary and secondary control to achieve the desired flame picture When using solid fuel in this stove with a multi fuel kit installed you must only use smokeless fuel recommended for enclosed appliances Using the wrong fuel cannot only be dangerous but can cause the glass to craze The Ash pan w...

Страница 5: ... could make the stove smoke into the room If this should happen shut all the stove air controls open the windows and vacate the room until the smoke has cleared At all times consider the safety of yourself and others before taking the above action Downdraughts are generally caused by adverse weather or could be poor flue draught or not enough ventilation and not a fault with the stove If this occu...

Страница 6: ...yrene transit blocks holding the baffles Check all the fire bricks and baffle plates are in place and have not moved or been damaged in transit Inside the stove packed with these instructions will be gauntlet a universal tool and a tool to operate the tertiary air slider Before lighting the stove you must check that the installation has been carried out as per instructions and complies with curren...

Страница 7: ...rther than the above minimum to help prevent any ash on the door falling onto the floor when the stove door is opened If the stove is installed into a fire opening made of non combustible materials we recommend a minimum of 150mm gap to the sides 300mm above and 50mm behind the stove For minimum distances to combustible material see below The both the Dartmoor 5 and W5 must be installed on a const...

Страница 8: ...st make sure all the fire bricks and baffles plates are in place Particular attention must be taken when checking the top baffle plate is in place See diagram below The Top vermiculite baffle sits on a ledge across the front and on an angle bracket to each side towards the rear If the top baffle has a section cut out this must be positioned with the cut out at the rear The lower baffle on the W5 i...

Страница 9: ...egister plate must be present or a soot box fitted in the back or side of the fireplace to enable access to clean the chimney when the stove is installed without a liner If the chimney has been lined and cannot be swept through the stove an access door on the first length of flue must be installed for cleaning access When using a back box the correct Dartmoor baker back box with a cleaning access ...

Страница 10: ...er appliance fitted within the room must be taken into account Please Note Extractor fans when operating in the same room or space as the appliance may cause problems Extra air venting must be in place to counteract this affect Air vent inlet grills must not be inadvertently blocked Air vents must not be fitted in positions where they can be inadvertently covered up As from the 1st October 2010 a ...

Страница 11: ...ew the stainless steel knob J off the riddle bar and hook the bar through the hole in the arm of the centre grate D making sure the riddle bar sits under the centre grate arm 3 Fit the centre grate D with the arm pointing to the left and feed the riddle bar through the hole in the front of the stove 4 Re fit the baffle plate B using the new shorter side bricks 5 Fit the rear infill plate E The sup...

Страница 12: ...rtmoor Baker W5 Eco with Multi fuel kit installed Now you are ready to install the multi fuel kit 1 Bolt the two grate supports G by bolting them through the base holes each side Make sure the inside nut is adjusted so when the lower nuts are tightened the brackets are not digging into the outer side brick The side bricks should just move when the nuts are tight 2 Fit the new fuel retainer making ...

Страница 13: ...Dartmoor wood and multifuel heating stove product range Steel bodied stove fitted with cast iron doors Supplied in various sizes to give a range of heat output options Are in conformity with the provisions of the following EC Directive S when installed in accordance with the installation instructions in the product documentation 98 106 EEC 305 2011 Construction Products Directive And the standards...

Страница 14: ... Fire Safety Satisfies Dartmoor 5 STDFEDDAB5 Co 13 0 Wood 0 08 Ancit 0 12 5Kw 82 1 Wood 5Kw 80 7 Ancit Dartmoor W5 STDFEDDABW5 co 13 0 Wood 0 11 Ancit 0 08 5Kw 83 1 Wood 5Kw 80 3 Ancit Release of dangerous substances None Surface temperature Satisfies Mechanical resistance to carry a chimney flue Maximum weight to be supported 30Kg Test laboratory 0692 Name M P Chew Signature Position Technical Di...

Страница 15: ...ciency Supplier s Name Model Energy Efficiency Class Energy Labelling of Local Space Heaters Dartmoor W5 Eco A 5 0 n a 72 1 82 1 Seasonal Space Efficiency Net Efficiency Supplier s Name Model Energy Efficiency Class Energy Labelling of Local Space Heaters Product Fiche according to Commission Delegated Regulation Dartmoor 5 Eco Nominal Heat Output to Room KW Nominal Heat Output to Water KW Dean St...

Страница 16: ...nstaller for any relevant guarantees applicable to the installation Dean Forge Fabrication Ltd will not be held liable for any consequential or incidental loss damage or injury however caused Claims under this guarantee should be first made through your retailer This guarantee is only applicable in the UK Nothing in this guarantee shall affect your statutory rights Exclusions The following consuma...

Страница 17: ...Page 17 of 18 ...

Страница 18: ...Ltd Dean Prior Buckfastleigh Devon TQ11 0LS PRODUCT REGISTRATION Name Address Phone Number Suppliers Details Name Address Phone Number Installers Details Name Address Phone Number Date of Purchase Date of Installation Stove Serial No Model ...

Отзывы: