52
TYPE
00
TYPE
01
TYPE
02
TYPE
03
INP
UT
S CO
NFIGUR
ATION
PARAMETERS
Allocation of CHANNEL 1 of remotes
• 000: NONE (unused parameter)
• 001: START (start)
• 002: PEDESTRIAN (pedestrian)
• 003: OPEN (separated open)
• 004: CLOSED (separated close)
• 005: Unused
• 006: Unused
• 007: ELOCK-IN (electric-lock activation. See P062)
• 008: AUX_IN (with NET_EXP only)
Ch1
Allocation of CHANNEL 2 of remotes
Ch2
Allocation of CHANNEL 3 of remotes
Ch3
Allocation of CHANNEL 4 of remotes
Ch4
Selection of type of remotes
• 000: HCS fix-code
• 001: HCS rolling-code
• 002: Dip-switch
OP
ERA
TORS
CO
NFIGUR
ATION P
ARAMETERS
Selection type of operators
• 000: GEKO - ANGOLO
• 001: LOOK - MAC - STING
• 002: GHOST 100/200
• 003: 500 - 502 - 902 - PASS - 550PL
• 004: STOP
• 005: LIVI 5/24
• 006: LIVI 8/24
• 007: REV
Selected work with or without encoders.
CAUTION: Remember to correctly set the jumpers J5 and J9 (see table 1)
WARNING: J5, J9 and P029 must be set correctly before performing the procedure for programming
• 000: motors with encoder
• 001: engines without encoder
Selectioning operators number
• 001: one operator
• 002: two operators
OP
ERA
TING P
ARAMETERS
Operators speed adjustment during slow-down while opening
15%tot........................100%tot
Operators speed adjustment during the stroke while opening
15%tot........................100%tot
Operators speed adjustment during the stroke while closing
15%tot........................100%tot
Operators speed adjustment during slow-down while closing
15%tot........................100%tot
Slow down duration adjustment while opening
0%tot............................80%to
Slow down duration adjustment while closing
0%tot............................80%tot
Operator 1 force adjustment while opening (if = 100% obstacle detection deactivated)
15%tot…...........................100%tot
Operator n.1 force adjustment while closing (if = 100% obstacle detection deactivated)
15%tot…...........................100%tot
TYPE 00 - 01 - 03 ONLY:
Operator n.2 force adjustment while opening (if = 100% obstacle detection
deactivated)
15%tot…...........................100%tot
TYPE 02 ONLY:
Secondary force adjustment in closing: adjusts the motor’s force during the last part of the
closing movement defined by P058
0%tot...................................100%tot
Operator n.2 force adjustment while closing (if = 100% obstacle detection deactivated)
15%tot…...........................100%tot
Automatic closing times adjustment (if = 0 automatic closing deactivated)
0sec...................................255sec
Pedestrian automatic closing time adjustment (se = 0 pedestrian automatic closing deactivated)
0sec...................................255sec
Pedestrian stroke duration adjustment
5%tot…...........................100%tot
Pre-flashing time adjustment
0sec…….10sec
Adjustment of phase displacement time while opening
0sec……………30sec
Adjustment of phase displacement time while closing
0sec……………30sec
Collectivity function: if it is activated it deactivates both opening and closing inputs for the whole duration of
automatic opening and closing
• 000: disabled
• 001: activated only upon opening
• 002: activated on automatic opening and closing