3 TECHNICAL SPECIFICATIONS
Power voltage (V)
230V ~ ±10% (50Hz)
Flashing output 230V
230 V ~ max 75mA art. LED230AI
Auxiliary power output (24Vaux)
24 V ~ max 200mA ( 24Vsic)
Safety power output (24Vsic)
Max motor power
2 x 500W max
Fuse F1
T5A 250V delayed
Fuse F2
T100mA 250V delayed
Operating temperature limit
-20÷50 °C
Radio receiver frequency
433,92 MHz rolling code encoding/dipswitch
Max. no. radio controls managed
30
4 ELECTRICAL CONNECTIONS
Complete the electrical connections following the indications in “Table 1” and the diagram on page 49-50.
WARNING
Connect to the 230V ~ 50 Hz mains using an omnipolar switch or other device that ensure omnipolar mains cut-off, with a
3,5 mm contact opening distance.
WARNING
For adequate electrical safety, keep low safety voltage wires (controls, electro-locks, antenna, auxiliary power) clearly separate
from 230V ~ power wires
(minimum 4 mm in air or 1 mm via supplementary insulation)
placing them in plastic raceways and securing
them with adequate clamps near terminal boards.
WARNING
All wires must be striped and unsheathed in the immediate vicinity of terminals. Keep wires slightly longer to subsequently
eliminate any excess.
Table 1 “terminal board connection”
1-2
Power input 230 V ~ - 50Hz (L = phase, N = neutral)
3-4
Flashing output 230 V ~ 50 Hz max 40W
5-6-7
Motor output 2 max 500W (5 = open, 6 = shared, 7 = closed)
8-9-10
Motor output 1 max 500W (8 = open, 9 = shared, 10 = closed)
11-13
Output 24 V ~ controlled safety device power. To be used for TX photocell and safety device power when checking their
operations at the beginning of every manoeuvre.
12-13
Output 24 V ~ auxiliary and uncontrolled safety device power. To be used for auxiliary device, RX photocell (in any case) and
safety device power when checking their operations at the beginning of every manoeuvre.
14
WARNING operations with 1 motor: N.C. input closing limit switch.
If not used, short circuit to terminal no. 19
WARNING operations with 2 motors: Input not used, short circuit to terminal no. 19
15
WARNING operations with 1 motor: N.C. input opening limit switch.
If not used, short circuit to terminal no. 19
WARNING operations with 2 motors: N.C. input external safety device. If triggered it reverses drive.
If not used, short circuit to terminal no. 19
16
N.C. input external safety device. If triggered it reverses drive.
If not used, short circuit to terminal no. 19
17
N.C. input photocell. If triggered during closing, it reverses drive.
If not used, short circuit to terminal no. 19
18
N.O. input start. If triggered, it opens or closes. It can operate in “reverse” or “jog” mode. It can also be used to connect a
timed contact.
19
Shared inputs
20
Antenna signal
21
Antenna grounding