Revised 23 June 2000
Pag 4
.
WARNING :
THE LAMP MUST BE REPLACED IF IT HAS BECOME DAMAGED OR DEFORMED .
6. CHARACTERISTICS AND PERFORMANCE DATA
DESCRIPTION
VALUE
Ü
Amperage
See lamp data ( from ballast to head ) or ballast manual ( supply to ballast)
Ü
MAX Ignition voltage ( hot lamp )
≅
25 KV
BALLAST TYPE
CONNECTION
DEB 575 w
Direct
DEB 575/1,200 W
Direct to 575 w socket
Ü
Connections to ballast
( Standard version )
Magnetic 575 K
Direct
Standard Version
Special Version ( * )
Ü
Connector type
7 Pin 24-2 Male with ring nut -
Type : Bayonet 3 ramps
7 pin ( 6 M - 1 F ) with threaded
ring nut – Type : German std M1
Ü
Lamp Holder
G 22
Ü
Power Cable ( from fixture to ballast )
7 x 1,5 mm
2
-
Rubber , for rough service
Ü
Protection Class
Class 1 – ground connection required through ballast
Ü
Protection Type
IP 22
Ü
Max
Housing surface temperature
120 °C
Ü
Weight of Fixture
6,9 Kg ( MO )
4 leaf
8 leaf
Ü
Weight of barndoor
0,63 kg.
0,85 kg.
Seat Diameter
Ring Diameter
Ü
Size of Barndoor ring
192 mm.
190 mm.(
≅
7”
1/2
)
Seat x scrims
Scrim Dia
.
Ü
Size of scrims and color frame
187 mm
185 mm (
≅
7”
1/4
)
( * ) = Special version with German std M1 connector are available only on special request and shall be used with special ballast
and extension cables for connector c ompatibility .
USABLE LAMPS
Manufacturer
Model
OSRAM
HMI 575 w / SE
PHILIPS
MSR HR 575 w
Other manufacturers may be used as long as they meet completely the technical specifications of the above lamps
7. PERIODIC INSPECTION
A. The condition of the internal wiring insulation shall be inspected and tested every 500 working hours and at
least once a year. This frequency may need to be increased if rough or unknown (eg. rental) treatment is
incurred. Replace only with original De Sisti Lighting spare parts. Non-original cables may not withstand the
thermal and mechanical conditions of use
B. The lamp condition must be checked every 100 working hours. In order to avoid explosion the lamp should
be changed if it has become damaged or deformed. Follow the instructions supplied by the lamp
manufacturer.
C.
Check the condition of the safety shield (see section 4 : Installation Instructions) before every use.
D.
High Voltage components : High voltage wires ( from igniter to lampholder ) , their external shield , and the
lampholder must be inspected every 100 working hours and at least once a year . They shall be replaced as
soon as any mechanical cracking , even if minor , or visible thermal damage is discovered.
E.
The behaviour of the safety microswitch ( on door closure ) must be checked every 250 working hours and
at least ones a year .
F .
The correct status , functionality and tightening of the lensdoor assembly ( including hinge and door
catch ) must be checked once a year , or more frequently depending on the use , to ensure that the
accessories are correctly retained and the door properly fixed and retained when closed .
G.
Check the condition of the mirror every 250 working hours and replace as soon as it becomes cracked
or opaque . It is essential for good light performance and correct thermal behaviour .