3. SAFETY INSTRUCTIONS

Â

 

Professional use: 

This luminaire has been designed for professional use and must be operated by

qualified personnel only. 

Not for residential use.

Â

 

Grounding: 

 This luminaire is used only with De Sisti ballast . THE BALLAST MUST BE GROUNDED 

.

Â

 

Electrical connections 

:

  DO NOT  CONNECT THIS LUMINAIRE  DIRECTLY TO THE  ELECTRICAL MAINS .

  The supply cord ends  with a dedicated  connector . By this connector  the luminaire must be connected

to PROPERLY RATED  DE SISTI BALLAST ,  magnetic or electronic .

  The wiring diagram of  lamp house and connector  is shown herebelow

Working conditions

Â

 Working Position

Lighting fixture:

 Max. Tilting 

±

 90 ° from horizontal

Lamp:

 any

( see lamp catalogue )

Â

 Ambient Temperature, 

t

a

+45° C  Max

Top

Back

Sides

Front

Â

  Minimum distances from

inflammable surfaces

0,5 m.

0,2 m.

0,2 m.

3,0  m.

The luminaire should never be OPERATED close to inflammable materials. The ones indicated in the above
table are the minimum distances recommended.

Other requirements for safe use are:

MOD.2510 (MANUAL OPERATED)

Содержание REMBRANDT PICCOLO 1.200 w SE

Страница 1: ...rience and leadership in design innovation and manufacturing of lighting products for the professional Entertainment Industry means you can depend upon the quality of this product The REMBRANDT PICCOLO 1200 W SE is a compact highly efficient fresnel lens Spotlight using Single ended Hot Re strike metal halide discharge lamps having G38 base and LCL 107 mm NOTE Also available on special requests ei...

Страница 2: ...r By this connector the luminaire must be connected to PROPERLY RATED DE SISTI BALLAST magnetic or electronic The wiring diagram of lamp house and connector is shown herebelow Working conditions  Working Position Lighting fixture Max Tilting 90 from horizontal Lamp any see lamp catalogue  Ambient Temperature ta 45 C Max Top Back Sides Front  Minimum distances from inflammable surfaces 0 5 m 0 2...

Страница 3: ...shields against the lamp explosion are present and in good condition They consist of a fresnel lens plus wire guard The fresnel lens is made of borosilicate untoughened glass D 150 mm thickness 5 mm typ 3 mm min compliant to DIN 15560 The wire guard is a mesh 25 mm x 25 mm or smallaer wire D 0 8 mm typ made by nickel coated or stainless steel After connection to the ballast follow the ballast inst...

Страница 4: ...tal treatment is incurred Replace only with original De Sisti Lighting spare parts Non original cables may not withstand the thermal and mechanical conditions of use B The lamp condition must be checked every 100 working hours In order to avoid explosion the lamp should be changed if it has become damaged or deformed Follow the instructions supplied by the lamp manufacturer C Check the condition o...

Отзывы: