2. Important recommendations for EFU C 19 boilers
In case of
repeated burner defects
(
B33
), check following points:
`
Flame detection cell:
Check the presence of the supersensitive flame detection cell (including star ) to allow a better flame
detection.
The flame detection cells available in the spare parts centre under the reference
7626801
, are all supersensitive
versions.
`
In case of connecting an horizontal forced flue gas connection pipe (C13)
The use of DE DIETRICH connection accessories is recommended because they include a deflector limiting the
recirculation of flue gases.
The supplied deflector must imperatively be mounted.
Refer to the point 3. hereafter.
`
Check the connection of the oil supply:
The oil connection must comply with the instructions delivered with the Appliance, and with point
4.