De Dietrich Thermique EFU 22 Скачать руководство пользователя страница 2

BE - ER15012

2 / 5

IT2656

2. Important recommendations for EFU C 19 boilers 

In case of 

repeated burner defects

 (

B33

), check following points:

`

Flame detection cell:

Check the presence of the supersensitive flame detection cell (including star  ) to allow a better flame

detection. 

 The flame detection cells available in the spare parts centre under the reference 

7626801

, are all supersensitive 

versions.

`

In case of connecting an horizontal forced flue gas connection pipe (C13) 

The use of DE DIETRICH connection accessories is recommended because they include a deflector limiting the
recirculation of flue gases. 

The supplied deflector must imperatively be mounted. 
Refer to the point 3. hereafter.

`

Check the connection of the oil supply:

The oil connection must comply with the instructions delivered with the Appliance, and with point 

4.

 hereafter.

*